Larson Electronics Power Distribution Panel with 480 Volt Transformer - (6) 120v GFCI Outlets - 25 KVA substation

Larson Electronics

(No reviews yet) Write a Review
SKU:
MGS-25KVA-8C-480-120V-GFI
Weight:
0.00 LBS
Call for price
Made in the USA The Larson Electronics MGS-25KVA-8C-480-120V-GFI Temporary Power Distribution System converts 480 VAC three phase electrical current to single phase 120V AC and 240V AC 60hz. This power distribution system provides operators the ability to safely tap into and distribute 480VAC power from a variety of sources including generators and direct grid power. This portable substation is suitable for outdoor applications, with a fully potted transformer and NEMA 3R load center. This power distribution system is configured to transform 480V 3 phase to 120/240 Delta, so up to 5% of the capacity (1250 watts) can be used for lighting loads as well. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The MGS-25KVA-8C-480-120V-GFI temporary power distribution system provides a safe and reliable way for operators in industrial settings to tap into and utilize power sources independently of the work area. This unit provides an effective power distribution system for operators performing plant turnarounds, maintenance and cleaning in hazardous areas, equipment installations and repairs, and any activities requiring an alternative to native power sources. This portable transformer is designed to operate with 480v, three phase, 60hz which it then steps down to 1ph 120 VAC and 1ph 240 VAC. The power distribution system on this portable substation makes 120VAC available via six 20amp, 120v GFCI protected duplex receptacles and 240 VAC available via two 30amp, 250v, twist lock receptacles. Click Photo to Enlarge Click Photo to Enlarge Description: The MGS-25KVA-8C-480-120V-GFI portable power distribution substation converts three phase, 480 VAC electrical current to single phase 120V AC and 240V AC via a 25kva transformer (480v to 120/240v, 1ph, 60hz). 50ft of line power cord with a 30 amp, 480v, 3 phase /4 wire male plug is included to connect the substation to a primary 480v 3ph primary power supply. A fused disconnect, main on/off switch provides primary line protection and supplies primary power to the 25kva transformer. This power distribution system conforms to UL 1640. Secondary current is wired to a 120/240v, 1 phase, 100 amp load center with main breaker for circuit protection. 120/240 line out protection is provided by six 20amp, 125 Volt, 1 pole breakers and two 30amp, 250v, 2 pole breakers. Connection for 120-240VAC is through receptacles mounted on the side of the substation. Receptacles include six 20amp, 120v, GFCI waterproof duplex receptacles and two 30amp, 250v receptacles. The load center is mounted within NEMA 4/12 enclosure (Optional Glass Door) for protection against accidental contact, rain, dust, splashing water, and sprayed water. The transformer and load center/distribution assembly is mounted to a 1/8” thick diamond plate and the distribution assembly is mounted onto a rugged 2 inch square carbon steel frame with rectangular carbon steel skid pockets, locking casters, and a top located lifting eyelet to allow easy transport. The locking casters provide substation mobility, and a center point lift eye allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150kva and can be equipped with skids or trailer mounted. Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, hazardous location operations, shows, exhibits, and shipyard operations. These temporary power distribution systems are popularly used for HAZLOC applications where external power sources are often necessary and work well in combination with explosion proof lights and equipment. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGS-25KVA-8C-480-120V-GFI Temporary Power Distribution System Ratings Line In: Three Phase, 480 VAC 60Hz UL 1640 Portable Power-Distribution Equipment Disconnect 1: 30 amp 480v, 3ph, Fused NEMA 3R Indoor or Outdoor Use Output- 1 Ph 120V Outlets: 6- 20 Amp Waterproof GFCI Protected Receptacles Made in the USA Output- 1 Ph 240V Outlets: 2- 30amp, 250v, Twist Lock Receptacles Protection: 6-120V GFCI Outlets w/6 breakers, 2-250V Outlets w/2 Breakers, 100 amp Main Load Center with Breaker KVA: 25 Special Orders- Requirements Load Center: 120/240v, 1phase, 100 amp Single Main Breaker- NEMA 4/12 Enclosure Contact us for special requirements Dimensions: 36"W X 36"D X 36"T Toll Free: 888-325-4448 Weight: 650lbs E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews