Larson Electronics Temporary Power Distribution with 480 Volt Transformer and (8) 120v GFCI Outlets - 25KVA substation

Larson Electronics

(No reviews yet) Write a Review
SKU:
MGL25-480-8X120-2X250
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics MGL25-480-8X120-2X250 Temporary Power Distribution System converts 480 VAC to single phase 120VAC and 240VAC 60hz. This power distribution system provides operators the ability to safely tap into and distribute 480VAC power from a variety of sources including generators and direct grid power. This portable substation is suitable for outdoor applications with a fully potted transformer and NEMA 3R load center. This power distribution system is configured to transform 480V to 120/240V, so up to 5% of the capacity (1250 watts) can be used for lighting loads as well. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The MGL25-480-8X120-2X250 temporary power distribution system provides a safe and reliable way for operators in industrial settings to tap into and utilize power sources independently of the work area. This unit provides an effective power distribution system for operators performing plant turnarounds, maintenance and cleaning in hazardous areas, equipment installations and repairs, and any activities requiring an alternative to native power sources. This portable transformer is designed to operate with 480v, 60hz which it then steps down to 1ph 120 VAC and 1ph 240 VAC. The power distribution system on this portable substation makes 120VAC available via eight 20amp, 120v GFCI protected duplex receptacles and 240 VAC available via two 30amp, 250v, twist lock receptacles. Description: The MGL25-480-8X120-2X250 portable power distribution substation converts 480 VAC to single phase 120VAC and 240VAC via a 25kva transformer (480v to 120/240v, 1ph, 60hz). 50` of #8 Type W line-in power cable with a 60 amp, 480V, 460P7W male plug is included to connect the substation to a primary 480V 3PH primary power supply. A fused disconnect, main on/off switch provides primary line protection and supplies primary power to the 25kva transformer. This power distribution system conforms to UL 1640. Secondary current is wired to a 120/240v, 1 phase, 125 amp main lug panel. 120/240 line out protection is provided by eight 20 amp, 125 Volt, 1 pole breakers and two 30amp, 250v, 2 pole breakers. Connection for 120-240VAC is through receptacles mounted on the side of the substation. Receptacles include eight 20amp, 125v, GFCI waterproof duplex receptacles and two 30amp, 250v receptacles. The load center is mounted within NEMA 3R enclosure (optional glass door) for protection against accidental contact, rain, dust, splashing water, and sprayed water. The transformer and load center/distribution assembly is mounted to a standard steel cart style frame resulting in an extremely stable, durable, and mobile power distribution platform. Two rubber tires and a cart style mounting platform provides easier substation mobility, and a center point lift eye allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150kva and can be equipped with skids or trailer mounted. Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, hazardous location operations, shows, exhibits, and shipyard operations. These temporary power distribution systems are popularly used for HAZLOC applications where external power sources are often necessary and work well in combination with explosion proof lights and equipment. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGL25-480-8X120-2X250 Temporary Power Distribution System Ratings Line In: 50` #8 Type W Cable w/ 460P7W Primary Max OCP: 60A @ 480V Primary Voltage: 480VAC 60Hz Secondary Max OCP: 100A @ 240V Disconnect: 480V 3Ph 60A Fused @ 60A N3R UL 1640 Portable Power-Distribution Equipment Transformer: 25KVA 480V to 120/240 1Ph N3R NEMA 3R Indoor or Outdoor Use Secondary Voltage: 120/240VAC 1Ph Made in the USA Panel: 120/240V 1Ph 100A MCB N3R Secondary Breakers: (2) 30A 2P 250V, (8) 20A 1P 125V Special Orders- Requirements Secondary Receptacles: (2) L6-30R, (8) 5-20R GFCI Contact us for special requirements Form Factor: Powder Coated Steel Dolly Cart w/ Run Flat Tires Toll Free: 888-325-4448 Dimensions: W-40" X D-40" X H-48" Weight: 350lbs E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews