Image coming soon

Larson Electronics Explosion Proof Exit Sign - Class I, Division 1 & 2 - IP65 - 220-240V 50hz - Emergency Battery Back-Up

Larson Electronics

(No reviews yet) Write a Review
SKU:
ATEX-EXP-EMG-EXT-LE6-1L-50HZ
Weight:
0.00 LBS
Call for price
Made in the USAThe ATEX-EXP-EMG-EXT-LE6-1L-50HZ Explosion Proof LED Exit Sign with emergency battery back up from Larson Electronics is Class I, Divisions 1 & 2, Groups B, C, D, Class I, Zones 1 & 2, Groups IIB+H2, IIA, Class II, Divisions 1 & 2, Groups E, F, G and Class III Divisions 1 & 2 rated for hazardous areas. Equipped with a 1.1 watt LED lamp, a 3 hour runtime and self diagnostic system, this failsafe exit sign helps show workers within hazardous environments where the exit is during power failures. This single sided exit sign is an ideal emergency exit marking solution for hazardous locations where failsafe reliability is a must. The ATEX-EXP-EMG-EXT-LE6-1L-50HZ is an effective option for operators who wish to ensure their hazardous workspaces employ the most up to date and reliable means of marking emergency exit-ways available. Under normal conditions this emergency exit lamp uses normal external power to illuminate its 1 watt LED array. In the case of power outages or in any situation where power is interrupted, this unit automatically switches to a battery backup which will power the unit for three hours or until power is restored. This fixture has three mounting options and is multi-voltage capable. Light Features: The ATEX-EXP-EMG-EXT-LE6-1L-50HZ features a backlit LED array that each contain eight LEDs, drawing a total of 1.1 watts. This explosion proof emergency LED fixture features brown-out, short circuit and voltage surge protection and has a low voltage disconnect which prevents damage to the battery caused by a deep discharge. This self-testing LED fixture will run for a minimum of 3 hours after a power failure thanks to the maintenance-free 3.6 volt NiCad battery. After emergency use, the battery takes 24 hours to completely recharge.Click Photo to EnlargeClick Photo to EnlargeThis emergency exit marking fixture is explosion proof and carries an integral battery backup power supply. When external power is cut due to outages or accidents this lamp automatically switches to its battery backup which will power the lamp for three hours, longer than the requirements specified in the NFPA 101. The ATEX-EXP-EMG-EXT-LE6-1L-50HZ sign panel is back illuminated by LEDs and as a result draws only 1.1 watt of power and has an extreme LED luminary lifespan rated at 15 years. This fixture is approved for outdoor use and is resistant to saltwater making it suitable for use in marine environments.Emergency Operation: The ATEX-EXP-EMG-EXT-LE6-1L-50HZ features a backup battery that will run the fixture for at least 90 minutes following a power outage or any other loss of power. The included emergency backup battery is a 3.6 volt NiCad rechargeable unit. These batteries are maintenance-free and have a life expectancy of 15 years while being able to operate in a wide variety of conditions including in temperatures ranging from 0¡C to +40¡C. This unit also features a low voltage disconnect. This means that if the fixture detects that the battery`s terminal voltage has fallen below a certain level, the low voltage circuit will disconnect the emergency lighting load until normal power is restored. This prevents the battery from experiencing a deep discharge and becoming damaged.Wiring: The ATEX-EXP-EMG-EXT-LE6-1L-50HZ explosion proof emergency self-testing LED fixture is NOT a factory sealed fixture. Operators will bring their own wiring to a junction box and complete their connects. The operator will also provide their own seal off for this fixture. The ATEX-EXP-EMG-EXT-LE6-1L-50HZ operates on 220/240V AC at 50Hz.Mounting: The EXP-EMG-2L-LE6 is designed to be surface mounted to flat surfaces such as walls. The unions connecting the upper lamps to the lower indicator light enclosure allow for both horizontal and vertical adjustment. This gives operators the ability to adjust the light to their specific mounting location for ideal light coverage during a power failure or power outage.Suggested Applications: The EXP-EMG-2L-LE6 is designed to for use within hazardous environments to mark the exit-ways of rooms and buildings.At Larson Electronics, we do more than meet your lighting needs. We also provide replacement, retrofit, and upgrade parts as well as industrial grade power accessories. Our craftsmen can custom build any lighting system and/or accessories to fit the unique demands of your operation. A commitment to honesty, quality, and dependability has made Larson Electronics a leader in the lighting and electronics business since 1973. Contact us today at 800-369-6671 or [email protected] for more information about our custom options tailored to meet your specific industry needs.Made in the USA Quality Superior LED Benefits1. Uniform LED illumination2. Battery Replacement Notification Built In3. Universal 220V/240V AC Selectable4. 3 Hour Battery Backup Runtime5. Copper-free aluminum housing6. 3/4” NPT conduit hubs7. Maintenance free8. 15 Year LED Rated Lifespan9. Fully Automatic Operation10. Self Testing System11. High Intensity LEDs12. Low Power Consumption (1.1 watts)13. Fully Electronic Circuit Control1. Extreme long life.2. High efficiency and low amp draw.3. High durability and reliability.4. Small size and light weight.5. 100% recyclable.6. No toxins-lead, mercury.7. High light output.8. Consistent color over time.9. High Versatility.10. No fragile glass used in construction. 12. Vibration/impact resistant.EXP-EMG-EXT-LE6-1L-50Hz Explosion Proof Exit Sign Ratings/ApprovalsListing: United States & Canada Class I, Divisions 1 & 2, Groups B, C, DLamp Type: LED Class I, Zones 1 & 2, Groups IIB+H2Dimensions: 25”H x 13”W x 10.5”D Class II, Divisions 1 & 2, Groups E, F, GVoltage: 220/240VAC Class III Divisions 1 & 2Watts: 1.1 EX I I 2 G / DLighting Configuration: Back Illuminated Sign Panel Ex db IIC Gb, Ex tb IIIC Db IP66Battery Backup Runtime: 3 Hours Ta = -20¡C to +60¡CBattery Backup: Nickel Cadmium Battery Pack Self-Testing UnitFaceplate Color: Copper Free Aluminum Housing 3 Hour Emergency RuntimeMaterials: Red or Green ounting: Ceiling Mount, Pendant Mount, Wall Mount Special Orders- RequirementsWiring: 3/4" NPT Wiring Hub Contact us for special requirements? Phone: 1-214-616-6180? Toll Free: 888-325-4448? Fax: 1-903-498-3364E-mail: [email protected]

Reviews