Image coming soon

Larson Electronics 25 KVA Temporary Power Substation - 600V to 120/240V 1PH - (2) ADR3033 (2) L6-30R (6) 5-20R GFCI

Larson Electronics

(No reviews yet) Write a Review
SKU:
MGS-2X600.30A-25KVA-2X240.30A-6X120.20A
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics MGS-2X600.30A-25KVA-2X240.30A-6X120.20A power distribution substation converts 600V AC three phase electrical current into 120/240V AC single phase. This unit provides operators the ability to safely tap into and distribute 600V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and UseThe MGS-2X600.30A-25KVA-2X240.30A-6X120.20A portable power distribution system gives operators the ability to power their 600 volt, 240 volt and 120 volt equipment from a single system. On the primary side, operators connect three-phase 600V line-in power via 100` of #8 2,000V industrial grade Type W cord and to two ADR3033 receptacles for 600V equipment. On the secondary side, operators connect to two L6-30R receptacles for 240V equipment and to six 5-20R GFCI receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: The 100` of #8 2,000V industrial grade Type W line-in cord brings 600V three phase power to the NEMA 3R 60-amp 600V three phase primary main circuit breaker panel, which contains two 30-amp 3-pole 600V breakers protecting two 30-amp 600V ADR3033 receptacles and one 60-amp 3-pole 600V breaker, and passes 600V single phase to the transformer. The NEMA 3R 25 KVA transformer converts 600V single phase power to 120/240V single phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 125-amp 120/240V single phase main lug panel. This secondary panel contains two 30-amp 2-pole 250V breakers protecting two 30-amp L6-30R 250V receptacles and six 15-amp 1-pole 125V breakers protecting six 20-amp 125V 5-20R GFCI receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. This model is equipped with forklift skid pockets, locking casters, and a top located lifting eyelet allows easy lifting with cable or chain hooks. This can be replaced with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs for an additional cost. Larger units are available upon request, and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGS-2X600.30A-25KVA-2X240.30A-6X120.20A Power Distribution Transformer Ratings Line-In Cord: 100` #8 2,000V Industrial Grade Type W Cord Max OCP Primary: 60A @ 600V Line-In Cord Cap: Customer Provided Max Secondary Output: 104.2A @ 240V Primary Voltage: 600V 3PH UL 1640 Portable Power-Distribution Equipment Primary Disconnect: - NEMA 3R Indoor or Outdoor Use Primary Panel: 60A 600V 3PH MCB N3R Primary Breakers: (2) 30A 3P [600V], (1) 60A 3P [600V] Primary Receptacles: (2) 30A ADR3033 [600V] Primary Protection: Breakers, Disconnect, Weatherproof Covers Transformer: 25KVA 600V to 120/240V 1PH 60 Hz N3R Secondary Voltage: 120/240V 1PH Secondary Panel: 125A 120/240V 1PH MLO N3R Secondary Breakers: (2) 30A 2P [250V], (6) 15A 1P [125V] Secondary Receptacles: (2) 30A L6-30R [250V], (6) 20A 5-20R [125V] Special Orders- Requirements Secondary Protection: GFCI, Breakers, Weatherproof Covers Contact us for special requirements Form Factor: Square tube frame w/ 1/8" side walls, hinged access doors, skid pockets, top pick eye & 8” locking casters Phone: 1-214-616-6180 Frame Materials: Powder coated steel frame Toll Free: 888-325-4448 Dimensions: 34"L x 44"W x 58"H Fax: 1-903-498-3364 Weight: 600 pounds E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250*Scroll Down to Purchase

Reviews