Made in Texas The Larson Electronics MGL-480-3X50A-25KVA-120.240-4X120.20A temporary power distribution system converts 480 VAC current to single phase 120V AC and 240V AC 60 Hz. This power distribution system provides operators the ability to safely tap into and distribute 480V AC and 120V AC power from a variety of sources including generators and direct grid power. This portable substation is suitable for outdoor applications, with a fully potted transformer and NEMA 3R load center. This power distribution system is configured to transform 480V to 240/120V Delta. Operators can connect up to four devices on 120V circuits via 5-20R plugs and three 480V tools via the Californa Style CS8169 receptacles with covers. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The MGL-480-3X50A-25KVA-120.240-4X120.20A temporary power distribution system provides a safe and reliable way for operators in industrial settings to tap into and utilize power sources independently of the work area. This unit provides an effective power distribution system for operators performing plant turnarounds, maintenance, equipment installations and any activities requiring an alternative to native power sources. This portable transformer is designed to operate with 480V, three phase, 60hz which it then steps down to single phase 120V AC and single phase 240V AC. The power distribution system on this portable substation makes 120V AC available via (4) 5-20R 20A, 125V GFCI protected duplex receptacles and (3) 480V AC available via (3) CS8169 50A, 480V receptacles. Click Photo to Enlarge Click Photo to Enlarge Click Photo to Enlarge Operation: The 20` 4/4 SOOW line-in cord brings 480V three phase power to the NEMA 3R 125-amp main breaker 480V three phase primary main panel, which contains three 50-amp breakers protecting three 50-amp, 480V CS8169 receptacles and one 60-amp, 480V breaker protecting the 25 KVA transformer. The NEMA 3R 25 KVA transformer converts 480V three phase power to 120/240V single phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 100-amp 120/240V single phase main lug panel. This secondary panel contains four 20-amp, 120V breakers protecting four 20-amp 5-20R GFCI protected duplex receptacles. All receptacles are equipped with weatherproof covers. The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style frame, resulting in an extremely stable, durable, and mobile power distribution platform. Two run-flat rubber tires and a dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA and can be equipped with skids or trailer mounted. Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 orinfo@lightingandsupplies.com to discuss your specific requirements. Specifications / Additional Information MGL-480-3X50A-25KVA-120.240-4X120.20A Temporary Power Distribution Line-In Cord: 20` 4/4 SOOW Cord Max OCP Primary: 125A @ 480V Line-In Cord Cap: Customer Provided UL 1640 Portable Power-Distribution Equipment Primary Voltage: 480V 3-Phase NEMA 3R Indoor or Outdoor Use Primary Disconnect: - Made in the USA Primary Panel: 480V 125A MB N3R Primary Breakers: (3) 50A [480V RCPT], (1) 60A [XMFR] Primary Receptacles: (3) CS8169 Primary Protection: Main Breaker, Weatherproof Covers Transformer: 25KVA 480V 3-Phase to 120/240V 1-Phase N3R Secondary Voltage: 120/240V 1-Phase Secondary Panel: 120/240V 100A MLO N3R Secondary Breakers: (4) 20A [120V] Secondary Receptacles: (10) 20A 5-20R [120V] Secondary Protection: GFCI [5-20R], Weatherproof Covers Special Orders- Requirements Form Factor: Upright dolly cart w/ wheels Contact us for special requirements Frame Materials: Powder coated steel frame Toll Free: 888-325-4448 Dimensions: 40"W x 40"D x 48"H Weight: 550 lbs E-mail: info@lightingandsupplies.com Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase
Larson Electronics 25 KVA Temporary Power Distribution - 480V to 120/240V - (4) 20A 120V & (3) 50A 480V Receptacles
Larson Electronics
(No reviews yet)
Write a Review
Write a Review

Larson Electronics
Larson Electronics 25 KVA Temporary Power Distribution - 480V to 120/240V - (4) 20A 120V & (3) 50A 480V Receptacles
- SKU:
- MGL-480-3X50A-25KVA-120.240-4X120.20A
- UPC:
- Weight:
- 0.00 LBS
Call for price








!