Fluke 87V Industrial Multimeter

Fluke

$500.99
(No reviews yet) Write a Review
SKU:
FLUKE-87V
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke 87V Industrial Multimeter

The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.

  • Easy-access door for fast battery changes without breaking the calibration seal
  • Analog bar graph for fast changing or unstable signals
  • Large digit display with bright, two-level backlight for easier reading in low light
  • Touch Hold keeps readings on display even after removing probes

The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.

Built to highest safety standards

All the inputs in the 87V are updated to the third edition of the EN 61010-1 to CAT III 1000 V and CAT IV 600 V. The meter is designed to withstand spikes of more than 8000 V. You also benefit from an audible Input Alert warning if the test leads are placed in the incorrect input jacks for the measurement being made.

Removable holster with built in test lead and probe storage for convenience

The 87V has a removeable holster that also holds a test probe during testing for easier viewing. Relative mode lets you remove test lead resistance, improving accuracy of low-resistance measurements. To make your life even easier, the 87V fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.

Additional measurement features

The Fluke 87V is designed and built in the U.S. and comes with a lifetime warranty.

Ê
ÊFluke 115 Field Technicians Digital MultimeterFluke 87V Industrial MultimeterFluke 3000 FC Series Wireless MultimeterFluke 1587 FC Insulation MultimeterFluke 279 FC True-rms Thermal Multimeter
CAT ratingCAT III 600 VCAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
True-rms readings_____
Voltage AC/DC600 V1000 V1000 V1000 V1000 V
Current AC/DC10 A10 A400 mA400 mA2500 A AC (with iFlex)
Resistance40 M½50 M½50 M½50 M½50 M½
Capacitance10,000 _F10,000 _F10,000 _F10,000 _F10,000 _F
Temperature--200.0 ¡C to 1090 ¡Cwith t3000 FC-40 ¡C to 537 ¡CInfrared camera
-10 ¡C to 200 ¡C
Infrared camera----_
Additional
measurement
capabilities
Continuity/diode testFrequency,
continuity/diode test,
motor drive (VFD)
measurement,
duty cycle,
microamps, analog
bar graph, relative
reference
Frequency,
continuity/diode test.
Able to connect to
three 3000 FC
modules.
Frequency, Pi/DAR
timed ratio tests,
continuity/diode test, motor drive (VFD)
measurement,
microamps, relative
reference
Frequency,
continuity/diode test,
motor drive (VFD)
measurement


Key features

  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittents as fast as 250 µS with Peak Capture


Specifications
Voltage DCMaximum voltage1000 V
Accuracy±(0.05% + 1)
Maximum resolution10 µV
Voltage ACMaximum voltage1000 V
Accuracy±(0.7% + 2) True RMS
AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution0.1 mV
Current DCMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(0.2% + 2)
Maximum resolution0.01 µA
Current ACMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(1.0% + 2) True RMS
Maximum resolution0.1 µA
ResistanceMaximum resistance50 M½
Accuracy±(0.2% + 1)
Maximum resolution0.1 ½
CapacitanceMaximum capacitance9,999 µF
accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyMaximum frequency200 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per kHz + 0.1%)
Maximum resolution0.1%
Temperature measurementÐ200.0 ¡C Ð 1090 ¡C
Ð328.0 ¡F Ð 1994.0 ¡F
excluding probe
80 BK temperature probeÐ40.0 ¡C Ð 260 ¡C
Ð40.0 ¡F Ð 500 ¡F, 2.2 ¡C or 2% whichever is greater
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty cycle rangeAccuracyWithin ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperatureÐ20 ¡C to + 55 ¡C
Storage temperatureÐ40 ¡C to + 60 ¡C
Humidity (without condensation)0% Ð 90% (0 ¡C Ð 35 ¡C)
0% Ð 70% (35 ¡C Ð 55 ¡C)
Operating Altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010Ð1 to 1000 V CAT III, 600V CAT IV
Agency approvalsCE, CSA, RCM
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g
624 g Ð with holster
DisplayDigital6000 counts updates 4/sec.
19,999 counts in highÐresolution mode
Analog32 segments, updates 40/sec
Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery LifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010Ð1:2001
VibrationPer MILÐPRFÐ28800 for a Class 2 instrument

Reviews