Omnify Lighting 12V 150W Hardwire Power Adaptor Power & Control

Omnify Lighting

(No reviews yet) Write a Review
SKU:
OL-12V 150W Hardwire Power Adaptor
Weight:
0.00 LBS
Call for price
Omnify Lighting 12V 150W Hardwire Power Adaptor Power & Control

12V / 150W Hardwire Power Adaptor

Save

Save

Save

Save

Save

Save

Save

Save

A 150 W constant voltage hardwire power adapter. Accommodates either 100 Ð 240 VAC or 277 VAC power sources.

KEY FEATURES & BENEFITS

  • Universal AC input / full range (up to 280 VAC)
  • IP65/IP67 leve
  • Built-in-active PFC function
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • OCP point adjustable through output cable or
    internal potential meter
  • Compliance to worldwide safety regulations for
    lighting
  • Low cost, high reliability

For your ease of reference, all product specifications have been provided in the form of a ready-to-download PDF.

General Information

Input
Voltage Range 1100 ~ 240 / 277 VAC
Frequency Range5.5 ~ 11 A47 ~ 63 Hz
Power FactorPF 0.95 / 230 VAC; PF 0.98 / 115 VAC at full load and rated output voltage; PF 0.9 at 75 ~ 100% load
Efficiency88%
AC Current2 A / 115 VAC; 1 A / 230 VAC
Inrush CurrentCold start 65 A / 230 VAC
Leakage Current< 1 mA / 240 VAC
Output
DC Voltage12 VDC
Power 150 W
Constant Current Region 29 ~ 12 V
Rated Current11 A
Rated Power132 W
Ripple and Noise 3150 mVp-p
Voltage Adj Range 49 ~ 13 V
Current Adj Range (adjustable by internal
potential meter / output cable)
5.5 ~ 11 A
Voltage Tolerance 5± 2%
Line Regulation± .5%
Load Regulation± 1%
Setup, Rise Time3000 ms, 80 ms at full load 230 VAC / 115 VAC
Hold Up Time (Typ.)50 ms / 230 VAC; 16 ms / 115 VAC at full load
Protection
Over Current 695 ~ 108%
Short Circuit 7Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 813.8 V ~ 16.2 V
Over Temperature 8100 ¡C ± 10 ¡C (RTH2)
Environment
Operating Temperature 9-30 ¡C ~ +55 ¡C at full load; 70 ¡C at 60% load
Storage Temperature-40 ¡C ~ +80 ¡C
Operating Humidity20 ~ 95% RH non-condensing
Storage Humidity10 ~ 95% RH
Temp. Coefficient± .03% / ¡C (0 ~ +50 ¡C)
Vibration10 ~ 500 Hz, 5G 12 minutes / 1 cycle, period for 72 minutes each along X, Y, Z axes
Withstanding VoltageI/P-O/P: 3.75 kVAC; I/P-FG: 1.88 kVAC; O/P-FG: 0.5 kVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG: 100 M Ohms / 500 VDC / 25¡C / 70% RH
EMI Conduction & Radiation Compliance to EN55015, EN55022 (CISPR22) Class B
Harmonic CurrentCompliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMS ImmunityCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4
kV), criteria A
Certifications 10Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
CertificationsUL1012 ; EN61347-1, EN61347-2-13 independent ; UL60950-1, TUV EN60950-1 (TBD)
Dimensions8 3/4Ó (222 mm) L x 2 11/16Ó (68 mm) W x 1 17/32Ó (39 mm) H
Additional
Mean Time Between Failures> 303 700 hours MIL-HDBK-217F (25 ¡C)
Packaging1.0 Kg; 12 pcs / 13 Kg / 0.49 ft3 (CLG-150-A/B); 1 Kg; 12 pcs / 13 K / 0.96 ft3 (CLG-150-C)

Reviews