types of devices for sanitation. Each shelf has four lamps on every wall including the door to ensures maximum exposure. This hazardous location UV cabinet turns off automatically when the door is open. A yellow indicator light turns on when the unit is in use to safely notify the operator about ongoing sanitation. With a recommended 5-minute exposure time at full capacity, multiple UV boxes can be purchased to clean several devices at the same time. Operators may access an external timer (set at 5 minutes from the factory) on the box to ensure the recommended duration of exposure is met every session. The UV light can disinfect over 99% of bacteria, viruses, mold, and spores. Voltage: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP operates on 120 V AC, 60 Hz. Purge and Pressurization System: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP uses a Type Z continuous flow purge and pressurization system that makes it safe to use within Class I Division 2 hazardous locations. In a purge and pressurization system, any hazardous gas is purged from the enclosure through a series of complete air exchanges. The enclosure is then pressurized to prevent the entry of any hazardous gas or dust from entering the enclosure. In a continuous flow purge system, like the one used in this UV oven, a constant flow of air following the purge is used to maintain internal pressure. The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP features a Type Z continuous flow purge system. A Type Z system requires a minimum of 25 Pa for internal pressure. The other main feature of a Type Z system is that power to the unit is automatically disconnected if a drop in pressure below the minimum occurs or any other loss of pressure occurs. This means that it then must go through the purge and pressurization process successfully again before operation can resume within the hazardous area. Operation: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP is equipped with a C1D1 rated push button for power and a C1D1 rated power indicator light on the outside of the unit. A timer is installed on the inside of the enclosure. The timer keeps the UV lamps running for the recommended amount of time to disinfect the desired items. To use the UV oven, the operator places the items in the racks on the inside of the oven, closes the gasketed door, secures the stainless steel draw latches, and pushes the power button. The unit then purges the enclosure and pressurizes it. Once pressurization is complete, power is provided to the timer. The UV lamps then power up and stay on throughout disinfection. This entire process must be repeated every time the lid is opened or pressure is otherwise lost. 5-15 Straight Blade Plug 5-20 Straight Blade Plug Wiring & Plug: This hazardous location UV oven is equipped with 25 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an explosion proof cord cap for easy connection to explosion proof outlets. Plug options include a 5-15 15 amp straight blade plug for use with 120 V explosion proof outlets or a 5-20 20 amp straight blade plug for use with 120 V explosion proof outlets. **PLEASE NOTE** voltage ratings on plugs and outlets are MAXIMUM voltage. For low voltage applications, proper voltage must be applied to the outlet or damage to the light fixture will occur. Mount: This hazardous location UV sanitation device has a flat base with four, 8" casters (two swivel-locking casters at the front and two stationary casters at the back) for seamless mobility and transportation, including over rough surfaces. An accessible handle at the back of the cabinet allows operators to move the unit around the site. We sell mounting lugs for permanent installations if needed. Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Suggested Applications: Sanitation, disinfection, warehouses, retail stores, event venues, commercial operations, POS, handheld devices and more; kills 99% of viruses, bacteria, mold and spores. Call 888-325-4448 to place your Larson Electronics order online today!
Larson Electronics HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP Mobile UV Hazardous Location Disinfection Cabinet 120V - (20) UV Lamps, Timer - (5) Mesh Wire Shelves - Type Z Purge System for C1D2 Use
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP Mobile UV Hazardous Location Disinfection Cabinet 120V - (20) UV Lamps, Timer - (5) Mesh Wire Shelves - Type Z Purge System for C1D2 Use
- SKU:
- HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP
- UPC:
- Weight:
- 0.00 LBS
!