Larson Electronics Explosion Proof Exit Sign - C1D1/2 - 120V 50/60Hz - 4" Letters, English/Spanish - Battery Backup - I

Larson Electronics

(No reviews yet) Write a Review
SKU:
EXP-EMG-EXT-LE6-1L-SLD-120V
Weight:
0.00 LBS
Call for price
The EXP-EMG-EXT-LE6-1L-SLD-120V from Larson Electronics is an Explosion Proof LED Exit Sign with Emergency Battery Backup that is Class I, Divisions 1 & 2, Groups B, C, D, Class I, Zones 1 & 2, Groups IIB+H2, IIA, Class II, Divisions 1 & 2, Groups E, F, G and Class III Divisions 1 & 2 rated for hazardous areas. Equipped with a 1.1 watt LED lamp, a 3 hour runtime and self diagnostic system, this failsafe exit sign helps show workers within hazardous environments where the exit is during power failures. This single-sided, English/Spanish exit sign features letters 4" in size and is an ideal emergency exit marking solution for hazardous locations where failsafe reliability is a must. The EXP-EMG-EXT-LE6-1L-SLD-120V is an effective option for operators who wish to ensure their hazardous workspaces employ the most up to date and reliable means of marking emergency exit-ways available. Under normal conditions this emergency exit lamp uses normal external power to illuminate its 1 watt LED array. In the case of power outages or in any situation where power is interrupted, this unit automatically switches to a battery backup which will power the unit for three hours or until power is restored. This fixture has three mounting options. The English/Spanish explosion proof exit sign reads: EXIT/SALIDA. Light Features: The EXP-EMG-EXT-LE6-1L-SLD-120V features a backlit LED array that each contain eight LEDs, drawing a total of 1.1 watts. This explosion proof emergency LED fixture features brown-out, short circuit and voltage surge protection and has a low voltage disconnect which prevents damage to the battery caused by a deep discharge. This self-testing LED fixture will run for a minimum of 3 hours after a power failure thanks to the maintenance-free 3.6 volt NiCad battery. After emergency use, the battery takes 24 hours to completely recharge. Click Photo to Enlarge Click Photo to Enlarge This emergency exit marking fixture is explosion proof and carries an integral battery backup power supply. When external power is cut due to outages or accidents this lamp automatically switches to its battery backup which will power the lamp for three hours, longer than the requirements specified in the NFPA 101. The EXP-EMG-EXT-LE6-1L-SLD-120V sign panel is back illuminated by LEDs and as a result draws only 1.1 watt of power and has an extreme LED luminary lifespan rated at 15 years. This fixture is approved for outdoor use and is resistant to saltwater making it suitable for use in marine environments. Emergency Operation: The EXP-EMG-EXT-LE6-1L-SLD-120V features a backup battery that will run the fixture for at least 90 minutes following a power outage or any other loss of power. The included emergency backup battery is a 3.6 volt NiCad rechargeable unit. These batteries are maintenance-free and have a life expectancy of 15 years while being able to operate in a wide variety of conditions including in temperatures ranging from 0¡C to +60¡C. This unit also features a low voltage disconnect. This means that if the fixture detects that the battery`s terminal voltage has fallen below a certain level, the low voltage circuit will disconnect the emergency lighting load until normal power is restored. This prevents the battery from experiencing a deep discharge and becoming damaged. Wiring: The EXP-EMG-EXT-LE6-1L-SLD-120V explosion proof emergency self-testing LED fixture is NOT a factory sealed fixture. Operators will bring their own wiring to a junction box and complete their connects. The operator will also provide their own seal off for this fixture. The EXP-EMG-EXT-LE6-1L-SLD-120V operates on 120 V AC at 60 Hz. Mounting: The EXP-EMG-EXT-LE6-1L-SLD-120V is designed to be surface mounted to flat surfaces such as walls. The unions connecting the upper lamps to the lower indicator light enclosure allow for both horizontal and vertical adjustment. This gives operators the ability to adjust the light to their specific mounting location for ideal light coverage during a power failure or power outage. Suggested Applications: The EXP-EMG-EXT-LE6-1L-SLD-120V is designed to for use within hazardous environments to mark the exit-ways of rooms and buildings. At Larson Electronics, we do more than meet your lighting needs. We also provide replacement, retrofit, and upgrade parts as well as industrial grade power accessories. Our craftsmen can custom build any lighting system and/or accessories to fit the unique demands of your operation. A commitment to honesty, quality, and dependability has made Larson Electronics a leader in the lighting and electronics business since 1973. Contact us today at 800-369-6671 or [email protected] for more information about our custom options tailored to meet your specific industry needs. Specifications / Additional Information EXP-EMG-EXT-LE6-1L-SLD-120V Explosion Proof Exit Sign Ratings/Approvals Listing: United States & Canada Class I, Divisions 1 & 2, Groups B, C, D Lamp Type: LED Class I, Zones 1 & 2, Groups IIB+H2 Dimensions: 25”H x 13”W x 10.5”D Class II, Divisions 1 & 2, Groups E, F, G Voltage: 120 V AC, 50/60 Hz Class III Divisions 1 & 2 Watts: 1.1 3 Hour Emergency Runtime Lighting Configuration: Back Illuminated Sign Panel Self-Testing Unit Battery Backup Runtime: 3 Hours English/Spanish Lettering Battery Backup: Nickel Cadmium Battery Pack Sign Lettering: EXIT/SALIDA Sign Color: Red or Green Ambient Temp Range: 0¡C to +60¡C Special Orders- Requirements Ambient Humidity: 0-100% Contact us for special requirements Weatherproof Rating: IP65 Phone: 1-214-616-6180 Materials: Copper Free Aluminum Housing Toll Free: 888-325-4448 Mounting: Ceiling Mount, Pendant Mount, Wall Mount Fax: 1-903-498-3364 Wiring: 3/4" NPT Wiring Hub E-mail: [email protected]

Reviews