Image coming soon

Larson Electronics 500 kVA Pad Mount Transformer - 12470V Delta Primary - 480GRDY/277 Wye-N Secondary - Oil Cooled

Larson Electronics

(No reviews yet) Write a Review
SKU:
MT-PMO-12470D-500KVA-480GRDY.277-N3R
Weight:
0.00 LBS
Call for price
The MT-PMO-12470D-500KVA-480GRDY.277-N3R 12470D 3 Phase Energy Efficient Pad Mount Dead Front Loop Feed Transformer from Larson Electronics is powerful, reliable and designed with the environment in mind. Suitable for both indoor and outdoor applications, the MT-PMO-12470D-500KVA-480GRDY.277-N3R provides increased reliablity and protection against critical equipment failures. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 500kVA, the MT-PMO-12470D-500KVA-480GRDY.277-N3R transformer is a three phase unit with a primary voltage of 12470V Delta. It also provides a secondary voltage of 480GRDY/277 Grounded Wye. Featuring robust construction, this unit`s cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology. The MT-PMO-12470D-500KVA-480GRDY.277-N3R is a grounded wye connection transformer and therefore must be connected phase-to-ground on a grounded wye system. This unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The Standard NEMA Type 3R enclosure makes the unit suitable for both indoor and outdoor applications and it can be pad mounted. The unit also features mineral oil cooling and a 65¡C temperature rise and is rated IP24. The MT-PMO-12470D-500KVA-480GRDY.277-N3R is designed so that no excess oil heating occurs from unbalanced loads or phase loss on the primary side. Benefits: The MT-PMO-12470D-500KVA-480GRDY.277-N3R pad mount dead front loop feed transformer offers many benefits to the consumer. Precision cut copper transformer winding material help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations. This transformer provides owners with significant energy savings as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Applications: General purposes. Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MT-PMO-12470D-500KVA-480GRDY.277-N3R Pad Mount Transformer Ratings Phase: Three Phase Listed for United States and Canada Frequency: 60Hz KNAN Cooling kVA: 500 IP24 Rated Primary Voltage: 12470V Delta Mineral Oil Filled Primary kV Class: 15kV Dead Front Primary Connection: Delta Loop Feed Primary BIL: 95kV Primary FCAN: 2 x 2.5% Primary FCBN: 2 x 2.5% Tap Changer: 100 Amp 5-Position Tap Changer Tap Changer: Primary Bushings: (6) 200 amp Cooper bushing wells with removable studs Inserts: (6) 15 kV, 95 kV BIL Cooper load-break inserts Load Breaking Switch: 15 kV, 630A 4-Position T-blade Arresters: No Overcurrent Protection: (3) Bayonet fuse in series with Partial-Range Current-Limiting Fuses Expulsion Fuses: (3) Bayonet fuses Bayonet Holder: (3) Copper Bayonet Fuse Holder Secondary Voltage: 480GRDY/277V Grounded Wye Secondary Connection: Grounded Wye Secondary kV Class: 1.2kV Secondary BIL: 30kV Secondary Bushings: (4) 5/8in copper stud with 4-hole screw-on spade bushings Accessories: Liquid Level Gauge Accessories: Thermometer, dial-type Accessories: Drain & Filter Valve Accessories: T-Type Loadbreak Oil Switch Accessories: Oil Fill & Sampling Valve Accessories: Pressure Vaccuum Gauge Accessories: Pressure relief device, 50 SCFm Accessories: Bay-O-Net Fuse + Current Limiting Fuse Accessories: Drain Valve with sampler in LV Compartment (1in) Accessories: Tank Ground Lug Tank Accessories: IEEE standard one-hole ground pads Tank Accessories: Nitrogen Blanket Cover: Bolted cover with handhole Winding Material: Copper Efficiency Standard: DOE 2010, 10 CFR Part 431 Efficiency Regulation @ 50% Load & 55¡C: >99.35% Cooling Class: KNAN Insulating Fluid: Envirotemp FR3 Mineral Oil Insulation Class: 105¡C Temperature Rise: 65¡C Ambient Temperature Rating: 40¡C Impedance (Std): 1.7% - 5.75% Sound Level: NEMA TR1 Standard Secondary Phase Angle: 30¡C Elevation: 1000M Above Sea Level IEEE K-Dimension: Loop feed per IEEE C57.12.34-2009 Figure 11 minimum dimensions (without bails) Cabinet: 20" Deep Cabinet Cabinet Construction: Stainless Steel Cabinet Hardware: Penta-Head Cabinet Door Bolts Special Orders- Requirements Finish: Munsell Green (Munsell 7GY 3.29/1.5) Topcoat Contact us for special requirements Dimensions: (Approx) 50.00"H x 79.00"W x 52.00"D Toll Free: 888-325-4448 Weight: 4400 lbs Mounting: Pad Mount E-mail: [email protected] -Scroll Down to Purchase-

Reviews