Larson Electronics 1500 kVA Pad Mount Transformer - 12470GRDY/7200 Grounded Wye Primary - 480Y/277 Secondary - Oil Cool

Larson Electronics

(No reviews yet) Write a Review
SKU:
MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R
Weight:
0.00 LBS
Call for price
The MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R 12470GRDY 3 Phase Energy Efficient Pad Mount Loop Feed Dead Front Transformer from Larson Electronics is powerful, reliable and designed with the environment in mind. Suitable for both indoor and outdoor applications, the MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R provides increased reliablity and protection against critical equipment failures. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses.*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*Transformer Features: With a transformer rating of 1500kVA, the MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R transformer is a three phase unit with a primary voltage of 12470GRDY/7200 Grounded Wye. It also provides a secondary voltage of 480Y/277 Wye. Featuring robust construction, this unit`s cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology. The MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R is a grounded wye connection transformer and therefore must be connected phase-to-ground on a grounded wye system.This unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The Standard NEMA Type 3R enclosure makes the unit suitable for both indoor and outdoor applications and it can be floor mounted. The unit also features mineral oil cooling and a 65¡C temperature rise and is rated IP24. The MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R is designed so that no excess oil heating occurs from unbalanced loads or phase loss on the primary side.Benefits: The MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R pad mount loop feed transformer offers many benefits to the consumer. Precision cut copper transformer winding material help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations.This transformer provides owners with significant energy savings as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Integrated floor and wall mounting brackets make installation fast and easy and the offset outward facing floor installation holes allow for easy power tool access.Applications: General purposes.Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. MT-PML-3P-12470Y.7200-1500KVA-480Y.277-N3R Pad Mount Transformer RatingsPhase: Three Phase Listed for United States and CanadaFrequency: 60Hz ONAN CoolingkVA: 1500 IP24 RatedPrimary Voltage: 12470GRDY/7200 Grounded Wye Mineral Oil FilledPrimary kV Class: 15kV Dead FrontPrimary Connection: Grounded Wye Loop FeedPrimary BIL: 95kV Primary FCAN: 2 x 2.5% Primary FCBN: 2 x 2.5% Tap Changer: 100 Amp 5-Position Tap Changer High Voltage Bushings: (6) 200A Copper Bushing Wells & Removeable Studs Neutral Bushing: 5/8" Copper Stud w/ 4-Hole Screw On Spade Bushing Load-Breaking Switch: None Arresters: None Overcurrent Protection: None Secondary Voltage: 480Y/277 Wye Secondary Connection: Wye Secondary BIL: 30kV Low Voltage kV Class: 1.2kV Low Voltage Bushings: (4) Integral Aluminum 12-Hole Spade Bushings Bushing Supports: Standard LV Bushing Support Assembly IEEE K-Dimension: Loop Feed per IEEE C57.12.34-2015 Figure 11 Minimum Dimensions (Without Bails) Notifications: Danger High Voltage Decal Notifications: Mr. Ouch Decal Assembly - English/Spanish Notifications: Non-PCB Decal Gauges & Fittings: Liquid Level Gauge Gauges & Fittings: Thermometer - Dial Type Gauges & Fittings: Pressure/Vacuum Gauge Gauges & Fittings: 1" Drain Valve w/ Sample in LV Compartment Gauges & Fittings: Pressure Relief Device, 35 SCFM Tank Accessories: (3) IEEE Standard Two-Hole Ground Pads Winding Material: Copper Efficiency: DOE 2016 Cooling Class: ONAN Insulating Fluid: Mineral Oil Fluid Volume: 295 Gallons Fluid Weight: 2199 lbs Elevation: Designed for Operation at 1000M (3300`) Above Sea Level Temperature Rise: 65¡C Impedance (Std): 5.73% Sound Level: NEMA TR1 Standard Cabinet: 24" Deep Cabinet Cabinet Hardware: Penta-Head Cabinet Door Bolts Special Orders- RequirementsFinish: Munsell Green (Munsell 7GY 3.29/1.5) Topcoat Contact us for special requirementsDimensions: - Toll Free: 888-325-4448Weight: 9018 lbs Intl: 1-903-270-1187Mounting: Pad Mount E-mail: [email protected]

Reviews