Image coming soon

Larson Electronics 10KVA Power Distribution Panel - 460V to 115/230V 1PH - (2) L6-20R (1) L6-15R (2) 5-15R Duplex GFCI

Larson Electronics

(No reviews yet) Write a Review
SKU:
MPD-480V-10KVA-2X115.15A-3X230.15A
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics MPD-480V-10KVA-2X115.15A-3X230.15A power distribution substation converts single phase 460V AC electrical current into single phase 115/230V AC. This unit provides operators the ability to safely tap into and distribute 460V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use The MPD-480V-10KVA-2X115.15A-3X230.15A portable power distribution system gives operators the ability to power their 240 volt and 120 volt equipment from a single system. On the primary side, operators connect three phase 460 volt line-in power via 15` of #10 SOOW cord with a APJ6485 male-handle cord cap. On the secondary side, operators may access two L6-20R and one L6-15R receptacles for 240V equipment and two 5-15R duplex GFCI receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 15` #10 SOOW line-in cord with a 60-amp 600V rated APJ6485 male-handle plug brings three phase 460V power to the NEMA 3R 30-amp three phase 460V primary disconnect, which contains two 30-amp time delay fuses, and passes single phase 460V through to the transformer. The NEMA 3R 10 KVA transformer converts 460V to single phase 115/230V 60Hz and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 50-amp single phase 115/230V main circuit breaker panel. This secondary panel contains three 15-amp 2-pole 250V breakers protecting two 20-amp L6-20R 250V receptacles and one 15-amp L6-15R 250V receptacle, as well as two 15-amp 1-pole 125V breakers protecting two 15-amp 5-15R 125V duplex GFCI receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. This model is equipped with forklift skid pockets, locking casters and a top-located lifting eyelet which allows easy lifting with cable or chain hooks. This can be replaced for an additional cost with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs. Larger units are available upon request and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MPD-480V-10KVA-2X115.15A-3X230.15A Power Transformer Ratings Line-In Cord: 15` #10 SOOW Cable Max Primary OCP: 30A @ 460V Line-In Cord Cap: 60A 3PH APJ6485 Male Handle Plug [600V Rated] Max Secondary Output: 50A @ 230V Primary Voltage: 460V AC, 1PH UL 1640 Portable Power-Distribution Equipment Primary Disconnect: 30A 460V 3PH N3R Fused @ 30A NEMA 3R Indoor/Outdoor Use Primary Panel: - Made in the USA Primary Breakers: - Primary Receptacles: - Primary Protection: Disconnect, Time Delay Fuses Transformer: 10 KVA 460V to 115/230V 1PH 60Hz N3R Secondary Voltage: 115/230V AC, 1PH Secondary Disconnect: - Secondary Panel: 50A 115/230V 1PH MCB N3R Secondary Breakers: (3) 15A 2P [250V], (2) 15A 1P [125V] Secondary Receptacles: (2) 20A L6-20R [250V], (1) 15A L6-15R [250V], (2) 15A 5-15R Duplex GFCI [125V] Special Orders- Requirements Secondary Protection: Circuit Breakers, GFCI, Weatherproof Covers Contact us for special requirements Form Factor: Square tube frame, skid pockets, top pick eye & 8” locking casters Phone: 1-214-616-6180 Frame Materials: Powder coated steel frame Toll Free: 888-325-4448 Dimensions: 34” X 44” X 58” Fax: 1-903-498-3364 Weight: 600 pounds E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews