Fluke Amprobe AT-6030 Advanced Wire Tracer Kit

Fluke

$1,759.99
(No reviews yet) Write a Review
SKU:
FLUKE-At-6030
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke Amprobe AT-6030 Advanced Wire Tracer Kit

A Receiver and powerful Transmitter are combined in this kit, designed to locate energized and de-energized wires, breakers, and fuses without having to disconnect any equipment. The Receiver features four tracing modes optimized for a range of applications. Its fully automatic breaker tracing capability saves time and eliminates the confusion of multiple false positives by detecting the highest recorded signal in a breaker or fuse. The Transmitter utilizes two optimized frequencies that allows for a clean and reliable signal. The Signal Clamp can be used in applications where there is no access to bare conductors by enabling the Transmitter to induce a signal into a wire through insulation. Whether youÕre a novice user or an expert, the AT-6030 Amprobe Advanced Wire Tracer kit will help you get the job done fast.

Product Highlights

  • Traces wires in walls, ceilings, floors and corners
  • Locates breakers and fuses
  • Pinpoints shorts and opens
  • High resolution 2.5_ TFT LCD color display
  • Three Transmitter signal modes: ÒHigh SignalÓ mode for normal circuits, ÒLow SignalÓ mode for precision tracing in difficult areasand ÒLoopÓ mode for closed loop de-energized circuits
  • Four Receiver tracing modes: ÒQuick ScanÓ mode allows for quick wire detection at a longer distance, ÒPrecisionÓ mode precisely pinpoints wires or faults located behind walls, floors, or ceilings, ÒBreaker IdentificationÓ mode facilitates quick and easy breaker locating and ÒNon-Contact Voltage DetectionÓ mode utilizes passive tracing without the Transmitter to verify if a wire is energized
  • Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
  • Comes with custom Amprobe hard carrying case, signal clamp, test leads and accessories


Key features

  • Work directly on an energized circuit without the need to take equipment offline
  • Save time searching for energized and de-energized wires hidden behind walls, ceilings and floors
  • Pinpoint wire location with the large color LCD Receiver screen featuring four unique modes
  • Identify breakers and fuses, as well as the location of a break, open or short
  • Non-Contact Voltage Detection utilizes passive tracing without the Transmitter to verify if a wire is energized
  • Includes the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors


     AT-6000-R ReceiverAT-6000-T TransmitterCT-400 Signal Clamp
    Measurement CategoryCAT III 600 VCAT III 600 VCAT IV 600 V, CAT III 1000 V
    Operating voltage0 to 600 V AC/DC0 to 600 V AC/DC0 to 1000 V AC
    Operating frequencyEnergized: 6.25 kHz
    De-Energized: 32.768 kHz
    Energized: 6.25 kHz
    De-Energized: 32.768 kHz
    Wire tracing: 32.768 kHz
    AC current measurement: 45 Hz to 400 Hz
    Hazardous voltage detectionSee NCV detection> 30 V AC/DCN/A
    Signal indicationsNumeric, bar graph display and audible beepLEDs and audible beepN/A
    Response timeTip Sensor (energized/de-energized): 500 MS
    NCV: 500 MS
    Battery voltage monitoring: 5 sec
    Line voltage monitoring: 1 sec
    Battery voltage monitoring: 5 sec
    Instantaneous
    Current output of signal (typical)N/AEnergized circuit:
    HI mode: 60 mA RMS
    LO mode: 30 mA RMS
    De-energized circuit:
    HI mode: 130 mA RMS
    LO mode: 40 mA RMS
    Loop mode: 160 mA RMS
    1 mA/A for AC current measurement with multimeter
    Signal voltage output (nominal)N/ADe-energized circuit:
    LOW: 29 V RMS, 120 Vp-p
    HIGH: 33V RMS, 140 Vp-p
    With CT-400:
    loop model: 31 V RMS, 120 Vp-p
    De-energized circuit:
    2.4 V RMS, 24 Vp-p
    Range detection (open air)Tip sensor (Energized):
    Max distance via air: up to 20 ft (6.1 m)
    Pinpointing: approx. 1.97 in (5 cm)
    Tip sensor (De-energized):
    Max distance via air: up to 14.7 ft (4.5 m)
    Pinpointing: approx. 1.97 in (5 cm)
    NCV detection (40 to 400 Hz):
    Max. sensitivity: 90 V up to 6.56 ft (2 m)
    Min. sensitivity: 600 V up to 0.39 in (1 cm)
    N/AN/A

    Reviews