A Receiver and powerful Transmitter are combined in this kit, designed to locate energized and de-energized wires, breakers, and fuses without having to disconnect any equipment. The Receiver features four tracing modes optimized for a range of applications. Its fully automatic breaker tracing capability saves time and eliminates the confusion of multiple false positives by detecting the highest recorded signal in a breaker or fuse. The Transmitter utilizes two optimized frequencies that allows for a clean and reliable signal. The Signal Clamp can be used in applications where there is no access to bare conductors by enabling the Transmitter to induce a signal into a wire through insulation. Whether youÕre a novice user or an expert, the AT-6030 Amprobe Advanced Wire Tracer kit will help you get the job done fast.
Product Highlights
- Traces wires in walls, ceilings, floors and corners
- Locates breakers and fuses
- Pinpoints shorts and opens
- High resolution 2.5_ TFT LCD color display
- Three Transmitter signal modes: ÒHigh SignalÓ mode for normal circuits, ÒLow SignalÓ mode for precision tracing in difficult areasand ÒLoopÓ mode for closed loop de-energized circuits
- Four Receiver tracing modes: ÒQuick ScanÓ mode allows for quick wire detection at a longer distance, ÒPrecisionÓ mode precisely pinpoints wires or faults located behind walls, floors, or ceilings, ÒBreaker IdentificationÓ mode facilitates quick and easy breaker locating and ÒNon-Contact Voltage DetectionÓ mode utilizes passive tracing without the Transmitter to verify if a wire is energized
- Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
- Comes with custom Amprobe hard carrying case, signal clamp, test leads and accessories
Key features
- Work directly on an energized circuit without the need to take equipment offline
- Save time searching for energized and de-energized wires hidden behind walls, ceilings and floors
- Pinpoint wire location with the large color LCD Receiver screen featuring four unique modes
- Identify breakers and fuses, as well as the location of a break, open or short
- Non-Contact Voltage Detection utilizes passive tracing without the Transmitter to verify if a wire is energized
- Includes the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors
AT-6000-R Receiver | AT-6000-T Transmitter | CT-400 Signal Clamp | |
---|---|---|---|
Measurement Category | CAT III 600 V | CAT III 600 V | CAT IV 600 V, CAT III 1000 V |
Operating voltage | 0 to 600 V AC/DC | 0 to 600 V AC/DC | 0 to 1000 V AC |
Operating frequency | Energized: 6.25 kHz De-Energized: 32.768 kHz | Energized: 6.25 kHz De-Energized: 32.768 kHz | Wire tracing: 32.768 kHz AC current measurement: 45 Hz to 400 Hz |
Hazardous voltage detection | See NCV detection | > 30 V AC/DC | N/A |
Signal indications | Numeric, bar graph display and audible beep | LEDs and audible beep | N/A |
Response time | Tip Sensor (energized/de-energized): 500 MS NCV: 500 MS Battery voltage monitoring: 5 sec | Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec | Instantaneous |
Current output of signal (typical) | N/A | Energized circuit: HI mode: 60 mA RMS LO mode: 30 mA RMS De-energized circuit: HI mode: 130 mA RMS LO mode: 40 mA RMS Loop mode: 160 mA RMS | 1 mA/A for AC current measurement with multimeter |
Signal voltage output (nominal) | N/A | De-energized circuit: LOW: 29 V RMS, 120 Vp-p HIGH: 33V RMS, 140 Vp-p With CT-400: loop model: 31 V RMS, 120 Vp-p | De-energized circuit: 2.4 V RMS, 24 Vp-p |
Range detection (open air) | Tip sensor (Energized): Max distance via air: up to 20 ft (6.1 m) Pinpointing: approx. 1.97 in (5 cm) Tip sensor (De-energized): Max distance via air: up to 14.7 ft (4.5 m) Pinpointing: approx. 1.97 in (5 cm) NCV detection (40 to 400 Hz): Max. sensitivity: 90 V up to 6.56 ft (2 m) Min. sensitivity: 600 V up to 0.39 in (1 cm) | N/A | N/A |