Fluke 750P Series Pressure Modules

Fluke

$2,348.99
(No reviews yet) Write a Review
SKU:
FLUKE-750P
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke 750P Series Pressure Modules

Fluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator into a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.

Measuring pressure with Fluke 750P Series Pressure modules is as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. And, with Òno tools requiredÓ connectors you donÕt even need to reach for a wrench to make connections.

When used with the 750 Series Documenting Process Calibrators pressure readings can even be date/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.

A complete family of pressure modules

With over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.

Choose from:

  • Differential modules
  • Gage modules
  • High pressure modules
  • Absolute modules
  • Vacuum modules
  • Dual range modules
  • Reference modules
  • Intrinsically safe modules

With more than 50 pressure modules to choose from, some of the more popular modules include:

  • Fluke 750P00
  • Fluke 750P02
  • Fluke 750PD2
  • Fluke 750P03
  • Fluke 750P05
  • Fluke 750P06
  • Fluke 750P29

Click the Models tab above for a full list of pressure modules.

Designed to go where you work

Pressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, thereÕs no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 ¡C to +50 ¡C.



Key features

  • A complete family of precision pressure modules
  • Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
  • 8 intrinsically safe models for use with Fluke 718EX or 725EX
  • Reduce errors by digitally sending measurements to calibrators
  • Precision measurements with reference uncertainties up to 0.01%


Differential ModuleÊSpecifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750P000 to 1 inH2O (0 to 2.5 mBar)30XDry airDry air
750P3IN0 to 3 Inch H2O (0 to 7.5 mbar)10XDry airDry air
750P5IN0 to 5 Inch H2O (0 to 12.5 mbar)6XDry airDry air
750P0170 to 10 inH2O (0 to 25 mBar)3XDry airDry air
750P020 to 1 psi (0 to 70 mBar)3XDry airDry air
750P220 to 1 psi (0 to 70 mBar)3X316 SSDry air
750P030 to 5 psi (0 to 350 mBar)3XDry airDry air
750P230 to 5 psi (0 to 350 mBar)4X316 SSDry air
750P040 to 15 psi (0 to 1 bar)3XDry airDry air
750P2470 to 15 psi (0 to 1 bar)4X316 SSDry air
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750P00±0.15%±0.3%±0.35%±0.25%±0.30%
750P3IN±0.15%±0.3%±0.35%±0.25%±0.30%
750P5IN±0.15%±0.3%±0.35%±0.25%±0.30%
750P017±0.1%±0.2%±0.3%±0.15%±0.25%
750P02±0.050%±0.1%±0.15%±0.075%±0.125%
750P22±0.050%±0.1%±0.15%±0.075%±0.125%
750P03±0.02%±0.04%±0.05%±0.035%±0.04%
750P23±0.02%±0.04%±0.05%±0.035%±0.04%
750P04±0.0175%±0.035%±0.045%±0.03%±0.04%
750P247±0.0175%±0.035%±0.045%±0.03%±0.04%
Gage ModuleÊSpecifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750P0570 to 30 psi (0 to 2 bar)4X316 SSN/A
750P0670 to 100 psi (0 to 7 bar)4X316 SSN/A
750P2770 to 300 psi (0 to 20 bar)4X316 SSN/A
750P070 to 500 psi (0 to 35 bar)4X316 SSN/A
750P080 to 1000 psi (0 to 70 bar)3X316 SSN/A
750P0970 to 1500 psi (0 to 100 bar)3X316 SSN/A
750P20000 to 2000 psi (0 to 140 bar)3X316 SSN/A
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750P057±0.0175%±0.035%±0.045%±0.03%±0.04%
750P067±0.0175%±0.035%±0.045%±0.03%±0.04%
750P277±0.0175%±0.035%±0.045%±0.03%±0.04%
750P07±0.0175%±0.035%±0.045%±0.03%±0.04%
750P08±0.0175%±0.035%±0.045%±0.03%±0.04%
750P097±0.0175%±0.035%± 0.045%±0.03%±0.04%
750P2000±0.0175%±0.035%± 0.045%±0.03%±0.04%
High Pressure ModuleÊSpecifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750P290 to 3000 psi (0 to 200 bar)3X316 SSN/A
750P300 to 5000 psi (0 to 340 bar)3X316 SSN/A
750P310 to 10000 psi (0 to 700 bar)2X316 SSN/A
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750P29±0.0175%±0.035%±0.045%±0.03%±0.04%
750P30±0.0175%±0.035%±0.045%±0.03%±0.04%
750P31±0.0175%±0.035%±0.045%±0.03%±0.04%
Absolute ModuleÊSpecifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750PA30 to 5 psia (0 to 350 mBar)4X316 SSN/A
750PA470 to 15 psia (0 to 1 bar)4X316 SSN/A
750PA50 to 30 psia (0 to 2 bar)4X316 SSN/A
750PA60 to 100 psia (0 to 7 bar)4X316 SSN/A
750PA270 to 300 psia (0 to 20 bar)4X316 SSN/A
750PA70 to 500 psia (0 to 35 bar)4X316 SSN/A
750PA80 to 1000 psia (0 to 70 bar)3X316 SSN/A
750PA90 to 1500 psia (0 to 100 bar)3X316 SSN/A
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750PA3±0.03%±0.06%±0.07%±0.05%±0.06%
750PA47±0.03%±0.06%±0.07%±0.05%±0.06%
750PA5±0.03%±0.06%±0.07%±0.05%±0.06%
750PA6±0.03%±0.06%±0.07%±0.05%±0.06%
750PA27±0.03%±0.06%±0.07%±0.05%±0.06%
750PA7±0.03%±0.06%±0.07%±0.05%±0.06%
750PA8±0.03%±0.06%±0.07%±0.05%±0.06%
750PA9±0.03%±0.06%±0.07%±0.05%±0.06%
Vacuum ModuleÊSpecifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750PV3-5 psi (-350 mBar)4X316 SSDry air
750PV4-15 psi (-1 bar)4X316 SSDry air
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750PV3±0.03%±0.06%±0.07%±0.05%±0.06%
750PV4±0.03%±0.06%±0.07%±0.05%±0.06%
Dual Range Specifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750PD2-1 to 1 psi (-70 to 70 mBar)4X316 SSDry air
750PD3-5 to 5 psi (-350 to 350 mBar)4X316 SSDry air
750PD10-10 to 10 psi (-700 to 700 mBar)4X316 SSDry air
750PD4-15 to 15 psi (-1 to 1 bar)4X316 SSDry air
750PD5-15 to 30 psi (-1 to 2 bar)4X316 SSÑ
750PD50-15 to 50 psi (-1 to 3.5 bar)4X316 SSÑ
750PD6-15 to 100 psi (-1 to 7 bar)4X316 SSÑ
750PD7-15 to 200 psi (-1 to 14 bar)4X316 SSÑ
750PD27-15 to 300 psi (-1 to 20 bar)4X316 SSÑ
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750PD2±0.05%±0.1%±0.15%±0.075%±0.125%
750PD3±0.03%±0.06%±0.07%±0.05%±0.06%
750PD10±0.025%±0.05%±0.07%±0.04%±0.06%
750PD4±0.0175%±0.035%±0.045%±0.03%± 0.04%
750PD5± 0.0175%± 0.035%± 0.045%±0.03%± 0.04%
750PD50± 0.0175%± 0.035%± 0.045%±0.03%± 0.04%
750PD6± 0.0175%± 0.035%± 0.045%±0.03%± 0.04%
750PD7± 0.0175%± 0.035%± 0.045%±0.03%± 0.04%
750PD27± 0.0175%± 0.035%± 0.045%±0.03%± 0.04%
Reference ModuleÊSpecifications
ModelParameter / rangeBurst rating6Hi side media2Lo side media2
750R0450 to 15 psi (0 to 1 bar)3XDry airDry air
750R0650 to 100 psi (0 to 7 bar)4X316 SSÑ
750R270 to 300 psi (0 to 20 bar)4X316 SSÑ
750R070 to 500 psi (0 to 35 bar)4X316 SSÑ
750R0850 to 1000 psi (0 to 70 bar)3X316 SSÑ
750R290 to 3000 psi (0 to 200 bar)3X316 SSÑ
750R300 to 5000 psi (0 to 340 bar)3X316 SSÑ
750R3150 to 10000 psi (0 to 700 bar)2X316 SSÑ
750RD5-15 to 30 psi (-1 to 2 bar)4XDry airÑ
750RD65-12 to 100 psi (-0.8 to 7 bar)4X316 SSÑ
750RD27-12 to 300 psi (-0.8 to 20 bar)4X316 SSÑ
ModelReference uncertainty4Total uncertainty
1-year
(15-35¡C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35¡C)
Total uncertainty
6-month1
750R045±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R065±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R27±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R07±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R085±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R29±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R30±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750R315±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750RD5±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750RD65±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
750RD27±0.01% of FS±0.02% of FS±0.04% of FS±0.015% of FS±0.035% of FS
1. Total uncertainty, % of full span for temperature range 0¡C to +50¡C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10¡C to 0¡C, one year interval. No 6 month specification available for range -10¡C to 0¡C.Ê
2. ÒNon-corrosive gassesÓ indicates Dry air or non-corrosive gas as compatible media. ÒStainless Steel 316-SSÓ indicates media compatible with Type 316 Stainless Steel.Ê
3. Specifications % of Full Span unless otherwise noted.Ê
4. Reference Uncertainty is the specification for as left data for 24 hours.Ê
5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification.Ê
6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure.Ê
7. Intrinsically Safe pressure module available in this pressure range.

Reviews