Fluke 700G Pressure Gauge Calibrator

Designed for field pressure calibration, the Fluke 700G Series Pressure Gauge Calibrators give you the performance and durability that you have come to expect in Fluke pressure calibration products while being simple and easy-to-use. Whether youÕre looking to connect to either a hydraulic or pneumatic test pump this series are designed to be a complete calibration solution with:

  • 23 pressure gauges from ±10 inH2O/20 mbar to 10,000 psi/690 bar

With a standard accuracy of 0.05% of full scale and reference class gauges with accuracies of 0.04% youÕre sure to find a gauge thatÕs the perfect fit for your application.

Pressure gauge data logging

The Fluke 700G series gauges and pump kits are designed for the pressure testing professional working on process pressure instrumentation. The pressure ranges of the 700G series gauges cover the ranges needed for process pressure calibration needs including Gage pressures +/- 10 inH20 (+/- 25 mbar) to 10,000 psi (0-690 bar), absolute pressures from 0 to 15 psia (0-1 bar) to 0-300 psi (0-20 bar) and reference class gauges from 0 to 30 PSI (0-2 bar) to 10,000 psi (0-690 bar).

  • Standard accuracy to 0.05% of full scale
  • Reference class gauges deliver 0.04% of reading measurement accuracy
  • Pressure gauge data logging for more than 8,493 pressure measurements to memory and uploads to a PC (with 700G/TRACK software)

Rugged design with intrinsically safe certification

  • Rugged sealed IP-67 enclosure with included protective holster
  • Allows you to work safely in classified areas known to include explosive gasses:
    • CSA: Class 1, Div2, Groups A-D rating
    • ATEX: II 3 G Ex ic IIB T6 Gc
  • Standard 3-year warranty

Easy to use pressure solution

Pressure gauge calibrators are the easiest to use of all pressure calibration tools. Power them up, connect to the pressure device you want to measure and see your measurement, itÕs that easy. When used with a Fluke-700PTPK pneumatic or 700HTPK hydraulic pump kit the 700G becomes a complete pressure sourcing and measurement solution. The 700PTPK2 and 700HTPK2 premium pump kits offer easy connectivity to the gauge and device under test providing Òno tools requiredÓ connections.

  • Complete pressure calibration solution when gauges are paired with special pump kits
    • Calibrate to 600 psi (20 bar) with the 700PTPK or 700PTPK2 pneumatic pump kit.
    • Calibrate to 10,000 psi (690 bar) with the 700HTPK or 700HTPK2 hydraulic pump kit.


Key features

  • Precision pressure gauge calibrators designed for fast, accurate test results
  • Make precise pressure measurements from ±10 inH2O/20 mbar to 10,000 psi/690 bar
  • Highly accurate; 0.05% measurement uncertainty for 1 year
  • Easily view in most environments with bright backlit display
  • Take your gauge anywhere with a rugged protective holster


700R Ranges: Temperature Compensation 0 e ¡C to 50 ¡C (32 ¡F to 122 ¡F) to rated accuracy.
For temperatures from -10 ¡C to 0 ¡C and 50 ¡C to 55 ¡C, add .005% FS/ ¡C
ModelRangeResolutionAccuracyBurst Pressure
Fluke-700G01-10 to +10 inH2O
-20 mbar to 20 mbar
0.001 inH2O,
0.001 mbar
Positive pressure ±0.1% of range,
Vacuum ±0.1% of range
3 psi,
210 mbar
Fluke-700G02-1 to +1 psi,
-70 mbar to 70 mbar
0.0001 psi,
0.001 mbar
Positive pressure ±0.1% of range,
Vacuum ±0.1% of range
5 psi,
350 mbar
Fluke-700G04-14 to 15 psi,
-0.97 to 1 bar
0.001 psi,
0.0001 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
60 psi,
4 bar
Fluke-700G05-14 to 30 psi,
-0.97 to 2 bar
0.001 psi,
0.0001 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
120 psi,
8 bar
Fluke-700G06-12 to 100 psi,
-0.83 to 6.9 bar
0.01 psi,
0.0001 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
400 psi,
26 bar
Fluke-700G27-12 to 300 psi,
-0.83 to 20 bar
0.01 psi,
0.001 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
1200 psi,
80 bar
Fluke-700G07-12 to 500 psi,
-0.83 to 34 bar
0.01 psi,
0.001 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
2000 psi,
138 bar
Fluke-700G08-14 to 1000 psi,
-0.97 to 69 bar
0.1 psi,
0.001 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
4000 psi,
266 bar
Fluke-700G10-14 to 2000 psi,
-.97 bar to 140 bar
0.1 psi,
0.01 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
8000 psi,
550 bar
Fluke-700G29-14 to 3000 psi,
-0.97 to 200 bar
0.1 psi,
0.01 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
10000 psi,
690 bar
Fluke-700G30-14 to 5000 psi,
-0.97 to 340 bar
0.1 psi,
0.01 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
10000 psi,
690 bar
Fluke-700G31-14 to 10000 psi,
-0.97 to 690 bar
1 psi,
0.01 bar
Positive pressure ±0.05% FS
Vacuum ±0.1% FS
20000 psi,
1035 bar
Fluke-700GA40 to 15 psia,
0 to 1 bar absolute
0.001 psi,
0.0001 bar
±0.05% of range60 psi,
4 bar
Fluke-700GA50 to 30 psia
0 to 2 bar absolute
0.001 psi,
0.0001 bar
±0.05% of range120 psi,
8 bar
Fluke-700GA60 to 100 psia,
0 to 6.9 bar absolute
0.01 psi,
0.0001 bar
±0.05% of range400 psi,
27 bar
Fluke-700GA270 to 300 psia,
0 to 20 bar absolute
0.01 psi,
0.001 bar
±0.05% of range1200 psi,
80 bar
Fluke-700RG05-14 to +30 psi,
-0.97 to +2 bar
0.001 psi,
0.0001 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.05% of range
90 psi,
6 bar
Fluke-700RG06-12 to 100 psi,
-0.83 to 6.9 bar
0.01 psi,
0.0001 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.1% of range
400 psi,
27 bar
Fluke-700RG07-12 to 500 psi,
-0.83 to 34
0.01 psi,
0.001 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.1% of range
2000 psi,
138 bar
Fluke-700RG08-14 to 1000 psi,
-0.97 to 69 bar
0.1 psi,
0.001 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.1% of range
4000 psi,
275 bar
Fluke-700RG29-14 to 3000 psi,
-0.97 to 200 bar
0.1 psi,
0.01 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.1% of range
10000 psi,
690 bar
Fluke-700RG30-14 to 5000 psi,
-0.97 to 340 bar
0.1 psi,
0.01 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.1% of range
15000 psi,
1035 bar
Fluke-700RG31-14 to 10000 psi,
-0.97 to 690 bar
1 psi,
0.01 bar
Positive pressure,
±0.04% of reading +.01% of range,
Vacuum ±0.1% of range
20000 psi,
1380 bar
Media compatibility
  • 10 inH2O, 1, 15, 30 psi: any clean dry non-corrosive gas
  • 100, 300, 500, 1000 psi: any liquids or gases compatible with 316 stainless steel and above 1000 psi: any non-flammable, non-toxic, non-explosive, non-oxidizing liquid or gas compatible with 316 stainless steel.
Mechanical Specifications
Dimensions (H x W x D)12.7 x 11.4 x 3.7 cm (5 x 4.5 x 1.5 in)
Pressure connection_ in NPT Male
Housing/WeightCast ZNAL 0.56 kg (1.22 lb) with holster
Display5-1/2 digits, 16.53 mm (0.65 in) high 20-segment bar graph, 0 to 100%
PowerThree (3) AA alkaline batteries
Battery life1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate

Reviews