4-in-1 Surge Protective Isolated Ground Quadruplex Receptacle Outlet, Heavy-Duty Industrial Specification Grade, 15 Amp, 125 Volt, Side Wire, NEMA 5-15R, 2-Pole, 3-Wire - Orange
LevitonÕs Surge Protection Devices can be used individually or as part of a coordinated application strategy, to protect sensitive electronic equipment, in industrial, commercial and residential locations, from the stress and degradation inflicted by voltage transients. Leviton Surge Protection Devices are compliant with UL 1449 Standards. LevitonÕs outstanding Surge Protection Devices divert damaging voltage transients, or surges, away from electronic equipment. Transients are diverted away from sensitive micro circuitry, providing protection against catastrophic failure, costly downtime and data disruptions.
Current Limiting: Full Rated Current
Dielectric Voltage: Withstands 2000V per UL498
Grounding: Isolated Ground
Pole: 2
Temperature Rise: Max 30C after 250 cycles OL at 200 percent rated current
Voltage: 125 VAC
Wire: 3
Operating Temperature: -40¡C to 60¡C
Clamp Nuts: Zinc-Plated Steel
Face Material: Nylon
Ground Clips: Brass-Plated Steel
Grounding Screw: Brass-Plated Steel
Line Contacts: Brass Triple-Wipe
Shutter Mechanism: Delrin¨ Acetal
Terminal Screws: Brass-Plated Steel
Yoke: Zinc-Plated Steel
Terminal Accom.: 14-10 AWG
Terminal ID: Brass-Hot, Green-Ground, Silver-Neutral
Termination: Back or Side Wire
Torque Range: 14-16 inch pounds
MCOV: 150V rms
Maximum Surge Current, Per Mode (Per Phase): 27kA (L-N:18kA, L-G:9kA)
Noise Rejection: -30dB at 500kHz-300MHz
Nominal Discharge Current Rating: 3kA
Short Circuit Current Rating: 5kA
UL1449 Impulse 6kV/500A L-N: 330V
VPR: L-N:500V, L-G:600V, N-G:500V
Brand: 4-in-1
Color: Orange
Device Type: Quadruplex Receptacle
Function: Surge Protective Isolated Ground
Grade: Commercial Specification Grade
NEMA: 5-15R
Noise Rejection: -30dB at 500kHz-300MHz
Termination: Back or Side Wire
UL1449 Impulse 6kV/500A L-N: 330V
Agency Certifications: UL 498, UL 1449 3rd Edition Listed and CSA C22.2 Certified Type 3
NEMA: WD-6
NOM: 057
UL Fed Spec WC-596: File E13399
Current Limiting: Full Rated Current
Dielectric Voltage: Withstands 2000V per UL498
Grounding: Isolated Ground
Pole: 2
Temperature Rise: Max 30C after 250 cycles OL at 200 percent rated current
Voltage: 125 VAC
Wire: 3
Operating Temperature: -40¡C to 60¡C
Clamp Nuts: Zinc-Plated Steel
Face Material: Nylon
Ground Clips: Brass-Plated Steel
Grounding Screw: Brass-Plated Steel
Line Contacts: Brass Triple-Wipe
Shutter Mechanism: Delrin¨ Acetal
Terminal Screws: Brass-Plated Steel
Yoke: Zinc-Plated Steel
Terminal Accom.: 14-10 AWG
Terminal ID: Brass-Hot, Green-Ground, Silver-Neutral
Termination: Back or Side Wire
Torque Range: 14-16 inch pounds
MCOV: 150V rms
Maximum Surge Current, Per Mode (Per Phase): 27kA (L-N:18kA, L-G:9kA)
Noise Rejection: -30dB at 500kHz-300MHz
Nominal Discharge Current Rating: 3kA
Short Circuit Current Rating: 5kA
UL1449 Impulse 6kV/500A L-N: 330V
VPR: L-N:500V, L-G:600V, N-G:500V
Brand: 4-in-1
Color: Orange
Device Type: Quadruplex Receptacle
Function: Surge Protective Isolated Ground
Grade: Commercial Specification Grade
NEMA: 5-15R
Noise Rejection: -30dB at 500kHz-300MHz
Termination: Back or Side Wire
UL1449 Impulse 6kV/500A L-N: 330V
Agency Certifications: UL 498, UL 1449 3rd Edition Listed and CSA C22.2 Certified Type 3
NEMA: WD-6
NOM: 057
UL Fed Spec WC-596: File E13399