Made in the USAThe Larson Electronics EPL-EMG-24-2L-BX Explosion Proof Fluorescent Four Bi-Axial Bulb Light Fixture is NRTL Listed for United States and Canada Class 1 Division 1, Class 2 Division 1 and 2, carries a T6 temperature rating and ideal for hazardous locations where flammable chemical/petrochemical vapors exist or have the potential to exist.The EPL-EMG-24-2L Emergency Light Fixture is a 2 foot long, 2 lamp, Class 1 Division 1 and Class II Division 1&2 explosion proof fluorescent light and an ideal choice for use in applications where space is at a premium. This T6 temperature rated fixture comes standard with two Bi-Axial 40 watt compact fluorescent bulbs which produce a combined 80 watts of illumination. The lamps are protected by heat and impact resistant Pyrex tubes and the fixture is constructed of copper free aluminum alloy. The lamp reflectors are corrosion resistant heavy gauge aluminum and coated with a high gloss reflective finish. This fixture is multi-voltage capable and is for use in paint spray booths.The EPL-EMG-24-2L-BX provides operators in hazardous locations with a compact, reliable and affordable lighting solution that provides the best explosion proof protection available without sacrificing light quality or fixture durability.Click Photo to EnlargeClick Photo to EnlargeClick Photo to EnlargeThis Biaxial light works, mounts and is wired like our EPL-48-2L explosion proof fluorescent light fixtures. The main difference is that we attach an extra Bodine ballast box to the unit that adds the emergency light functionality to the fixture. This explosion proof emergency light will run the standard 90 minutes after power is lost. The light recharges the battery once standard electrical power is restored and maintains the battery until needed again. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. For an additional charge, a second ballast can be added to run a second lamp for 1800 total lumens output for 90 minutes. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode.This Biaxial Lamp fixture is multi-voltage capable and can operate on voltages ranging through 100/120 Volts 60 HZ, 220 Volt 50 HZ, 240 Volt 60 HZ, and 277 Volts 60 HZ with 347 Volt and 480 Volt versions available upon request.Additional mounting options: Unless otherwise specified, our standard, most popular configuration is the bracket end mounting shown in the photos above. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit).Standard Bracket Mounts: Each bracket is cinched to the bracket mounting peg on each side of the light. The angle of the bracket is set by tightening two cap screws on either side of the bracket. The cap screws act as a set screw. The bracket itself is mounted via a single bolt hole at the top the bracket. There are two brackets, one on each end of the light. Once the brackets are mounted to a surface (ceiling, floor or wall), the light fixture can be removed from the brackets by loosening the cap screws that hold the bracket to the mounting peg. The first picture shown above illustrates the ballast side bracket and also shows the access caps for changing the bulbs. The second picture shows the bracket at the opposite end of the fluorescent light.Made in USA Quality Lamp Options1. Each unit dialectically tested.2. Fixture arrives assembled and lamped to reduce installation time and cost. Adjustable mounting brackets enable the operator to choose any mounting angle for the fixture, where other models may only offer one or three choices.3. Fixture constructed of extruded corrosion resistant copper free aluminum alloy.4. Over-sized, finned ballast housing for 800 mA fixtures provides more heat dissipation and extends ballast life. Larger ballast box accommodates High Output lamp ballasts. Ballast housing easily accessible and externally mounted. Top and bottom covers secured with nuts and bolts, instead of threaded through holes, which can be damaged with dirt.5. Heavy gauge extruded aluminum reflectors with high gloss reflective finish. Resists dents and corrosion.6. A wrench is used to unscrew the end caps for relamping the fixture, while other models require the tap and knock off method to loosen the end cap.7. Explosion proof, impact and heat resistant Pyrex tubes provide lamp protection.40 Watt Bi-Axial Compact Fluorescent Lamp - 4100K Color Temp, 3000 Lumens per LampClick here to see the LED version.Specifications / Additional Information EPL-EMG-24-2L-BX Explosion Proof RatingsNRTL Listed for United States & Canada Class 1 Division 1, Groups C and DLamp Type: Fluorescent Class 1 Division 2, Group A,B,C,DDimensions: W-11.25" L-27.5" H-8.5" Class II Division 1- 2, Groups E,F,GWeight: 25 Lbs NRTL Certified to UL 1598 Marine TypeVoltage: Multi- 120V-60hz 220V-50hz 240V-60hz 277V-60hz NRTL Certified to UL 844, 924Total Watts: 80 watts NRTL Certified to UL 595 Outdoor Marine Type (Saltwater)Total Lumens: 6000 Listed for Paint Spray Booths*Luminous Efficacy: 75 Lm/W California Title 24 CompliantLamp Life Expectancy: 20,000+ Hours Switch Leg for Powering Light On/OffColor Temp: 4100K Color Rendering Index: >75 CRI Beam Angle: N/A Power Efficiency: >95% Power Factor: 0.992 Ambient Operating Temp Range:-30¡ C to +70¡ C Operating Temp Rating: T6 Rated Special Orders- RequirementsMounting: Bracket Standard - Pendant Optional Contact us for special requirementsWiring Hub: 1/2 inch threaded Toll Free: 888-325-4448Minimum Operating Temp: -30¡ C Fax: 1-903-498-3364Maximum Case Temp: 90¡ C E-mail: [email protected]?
Larson Electronics Explosion Proof Fluorescent Emergency Light with Battery Backup - 2' 2 Lamp Fixture - Bi-Axial Bulb
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics Explosion Proof Fluorescent Emergency Light with Battery Backup - 2' 2 Lamp Fixture - Bi-Axial Bulb
- SKU:
- EPL-EMG-24-2L-BX
- UPC:
- Weight:
- 0.00 LBS
!