Made in the USAThe HALP-EMG-24-2L-2XH-T8 Hazardous Area Fluorescent Light Fixture from Larson Electronics is U.S./Canada UL Listed Class I Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperature rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime and either two 1/2" or 3/4" NPT threaded wiring hubs on both ends for a total of four.The HALP-EMG-24-2L-2XH-T8 hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class I Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class I Division 2, Groups A, B, C, D approved. The HALP-EMG-24-2L-2XH-T8 also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This fluorescent light works, mounts and is wired like our HALP-24-2L explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode. Click here to see the LED version of this lightNOTE ON LAMPS: This fixture comes equipped with F32-T8/841 - 17 Watt lamps producing 1,325 lumens per bulb, a 4100 Kelvin color and a 24,000 hour rated service life. Surface Mounting:Flange type aluminum mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 14.91" inches on center apart along the top of this hazardous location light. The mounting holes are 9.5" inches on center across the top of the light. Pendant Mounting: This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4" NPT hubs on either side of the fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture.Suggested Applications: The HALP-EMG-24-2L-2XH-T8 is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.Made in USA QualityLamp Options1. Each unit dialectically tested.2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface.3. Fixture housing constructed of glass fiber reinforced polyester.4. Relamping done via 6 stainless steel snap locking latches, which enable the operator to remove the door and access the lamps.5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection.6. 3/4" NPT threaded access holes for wiring conduit (Two per side). F32-T8/841 - 17 watt, 1325 lumens per bulb, 24,000 hours life, 4100 Kelvin color (Suffix -T8)Specifications / Additional Information HALP-EMG-24-2L-2XH-T8 Hazardous AreaU.L. RatingsUL Listing: United States - CanadaClass I Division 2, Groups A, B, C & D Lamp Type: FluorescentClass II Division 2 Groups F & GDimensions: W-8.25" L-52" H-7"Class III Weight: 8 Lbs IP65Voltage: Universal Voltage 120-277V AC 50/60 HzWet Area SuitableLow Voltage (Optional): 12-24V DCUL 1598Total Watts: 34 watts*UL 844 Total Lumens: STD-T8 Bulbs 2,650California Title 24 CompliantLuminous Efficacy STD-T8 Bulbs: 82.81 Lm/WSwitch Leg for Powering Light On/OffLamp Life Expectancy: STD-T8 Bulbs 24,000 HoursColor Temp: 4100K- T5HO Bulbs Beam Angle: 150¡Ambient Operating Temp Range:-40¡C to +65¡COperating Temp Range: T4C RatedSpecial Orders- RequirementsMounting: Surface (2) Flange Type Aluminum BracketsContact us for special requirements Wiring Hub: (4) 1/2" or 3/4" Thick Threaded NPT Hubs on Either SidesToll Free: 1-800-369-6671 U.L Approval: U.S Certificate Canada Certificate E-mail:[email protected]
Larson Electronics Class I Divsion 2 Emergency Fluorescent Light - 2' 2 Lamp - (4) NPT Threaded Wiring Hubs
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics Class I Divsion 2 Emergency Fluorescent Light - 2' 2 Lamp - (4) NPT Threaded Wiring Hubs
- SKU:
- HALP-EMG-24-2L-2XH-T8
- UPC:
- Weight:
- 0.00 LBS
Larson Electronics
Larson Electronics Class I Divsion 2 Emergency Fluorescent Light - 2' 2 Lamp
Larson Electronics
Larson Electronics Class I Division 2 Emergency Light 2' 2 Lamp
Larson Electronics
Larson Electronics Class I Division 2 Emergency LED Light - 2' 2 Lamp
!