Made in the USA The Larson Electronics MDP-4803-75K-250AB-12X20-2X208Y heavy duty power transformer substation converts 480VAC electrical current to 208Y/120VAC three phase. This unit provides operators the ability to safely tap into and distribute 120VAC and 208VAC power from a variety of sources including generators and direct grid power. This model is designed to support both linear (motor) and non-linear loads (lighting, computers, etc.). For that reason, we deliver 120V and 208V WYE on the secondary and provide a neutral. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The Larson Electronics MDP-4803-75K-250AB-12X20-2X208Y transformer provides a safe and effective way for operators in industrial settings to tap into and utilize power sources independently of the work area. This unit provides an effective power source for operators performing plant turnarounds, maintenance and cleaning in hazardous areas, equipment installations and repairs and any activities requiring an alternative to native power sources. Operation: 20` of #4/4 Type W cable terminated in a 4100P7W plug brings 480V three phase power to the 100-amp 480V 3-phase fused disconnect, which contains three 100-amp time delay fuses protecting the 75KVA transformer. The NEMA 3R transformer converts 480V to 208Y/120V three phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 225-amp main lug panel. This secondary panel contains twelve 125V 20-amp 1-pole breakers protecting twelve 20-amp 125V 520R-GFCI duplex receptacles and two 250V 30-amp 3-pole breakers protecting two 30-amp 208Y120V L21-30R twist lock receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. This model is equipped with forklift skid pockets, locking polyurethane casters, and a top located lifting eyelet allows easy lifting with cable or chain hooks. This can be replaced with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs for an additional cost. Larger units are available upon request, and can be equipped with skids or trailer mounted. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MDP-4803-75K-250AB-12X20-2X208Y Power Distribution System Ratings Line-In: 4100P7W with 20` #4-3c4w Type W Max Primary OCP: 100A @ 480V Primary Voltage: 480VAC 3PH Max PDU OCP: 100A @ 480V Primary Disconnect: 480V 3PH 100A N3R Fused @ 100A Max Secondary Output: 208.2A @ 240V Primary Protection: Time Delay Fuses UL 1640 Portable Power-Distribution Equipment Transformer KVA: 75KVA 480V to 208Y/120VAC 3PH N3R NEMA 3R Indoor or Outdoor Use Secondary Voltage: 208Y/120VAC 3PH Made in the USA Secondary Panel: 208Y/120V 3PH 225A MLO N3R Secondary Breakers: (12) 125V 1P 20A; (2) 250V 3P 30A Special Orders- Requirements Secondary Receptacles: (12) 520R-GCFI Duplex (125V), (2) L21-30R (208Y/125V) - All w/ Weatherproof covers Contact us for special requirements Secondary Protection: Breakers, GFCIs, Weatherproof Covers Toll Free: 888-325-4448 Form Factor: Square tube frame w/ skid pockets, top pick eye & locking 8” casters Dimensions: 34”-L X 40”-W X 58”-H E-mail: [email protected] Weight: 600 lbs *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase-

Reviews