Image coming soon

Larson Electronics 15KVA Temporary Power Distribution - 480V to 208Y/120V 3PH - (10) Receptacles - N3R MGL-480.3P.25A-15KVA-1X208.2P.30A-9X120.1P.20A-M1

Larson Electronics

(No reviews yet) Write a Review
Weight:
0.00 LBS
Call for price

This unit is Made In USA - Manufactured in Texas

The Larson Electronics MGL-480.3P.25A-15KVA-1X208.2P.30A-9X120.1P.20A-M1 temporary power distribution system converts three-phase 480V AC electrical current into three-phase 208Y/120V AC. This unit provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources including generators and direct grid power.

*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS*

The MGL-480.3P.25A-15KVA-1X208.2P.30A-9X120.1P.20A-M1 temporary power distribution system gives operators the ability to power their 208 volt and 120 volt equipment from a single system. On the primary side, operators connect 480 volt line-in power via 6` of #10 SOOW cord. On the secondary side, operators connect to one L6-30R receptacle for 208V equipment, six 5-20R duplex GFCI receptacles for 120V equipment and three 5-20R duplex red receptacles for 120V equipment. All receptacles are equipped with weatherproof covers.

Operation: A 6` #10 SOOW line-in cord brings three-phase 480V AC power to the NEMA 3R 30-amp, three-phase 480V primary disconnect, which contains three 25-amp time delay fuses, and passes power through to the transformer. The NEMA 3R 15 KVA transformer converts 480V to three-phase 208Y/120V 60Hz and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 50-amp, three-phase 208Y/120V main lug only panel. This secondary panel contains one 30-amp 2-pole 250V breaker protecting one 30-amp 250V L6-30R receptacle and nine 20-amp 1-pole 125V breakers protecting six 20-amp 125V 5-20R duplex GFCI receptacles and three 20-amp 125V 5-20R duplex receptacles.


Click Photo to Enlarge
Click Photo to Enlarge
Click Photo to Enlarge
Click Photo to Enlarge
Click Photo to Enlarge

Protective Construction: The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style, frame resulting in an extremely stable, durable, and mobile power distribution platform. Two run-flat rubber tires and a dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks.

This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150KVA, and can be equipped with skids or trailer mounted.

Certification: All units are built in accordance to NFPA 70 (National Electric Code). All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request.

Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground.
~Please check all motor loads for dual rated motors that will work 208 or 240.~


Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations.

Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or [email protected] to discuss your specific requirements.

Reviews