unit is Made In USA - Manufactured in Texas The Larson Electronics RNT-IND-UC.360-24-8L-UVC-AT-25CÊis an Industrial UV Portable Sanitation Light which can disinfect 99% of viruses, bacteria, mold, and spores in large facilities. This unit offers UV-C output at a range of 200nm - 280nm (254nm) and comes equipped with eight UVC fluorescent lamps. Four caster wheels on the bottom of the light allow for easy movement and positioning around the operating area. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. Click here to learn more about UVC and the coronavirus* The RNT-IND-UC.360-24-8L-UVC-AT-25CÊis a powerful sanitation solution for industrial sites and commercial facilities. Equipped with eight UVC fluorescent lamps, this system offers 72.8 watts of total UV output, within the 200nm - 280nm UV-C range (254 nm). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. This UV system caters to 1,000 square feet of space with 360 degrees of coverage. Operators may move the light around after exposure time to disinfect several sections. With a recommended 20-25 minute exposure time for viruses, multiple units can be purchased to cover larger areas quicker. The UV light kills 99% of viruses, bacteria, mold, and spores. At start up, there is a built-in 1-minute and 30-second delay to allow individuals to safely leave the room after deploying the device. An accessible digital timer enables operators to set exposure times. The lights will automatically turn off when the set time is complete. Operators may adjust settings via a controller at the bottom of the unit. Two warning signs and a pair of safety glasses are included with the device. Distance from Cart** Irradiance/Second Exposure Time Required* Coverage Area*** 6 inch 5418.00 uW/cm2 2.54 seconds 2.5 ft x 2.5 ft 12 inch 2721.60 uW/cm2 5.08 seconds 3.5 ft x 3.5 ft 18 inch 1512.00 uW/cm2 9.12 seconds 4.5 ft x 4.5 ft 2 foot 978.60 uW/cm2 14.10 seconds 5.5 ft x 5.5 ft 3 foot 512.40 uW/cm2 26.94 seconds 7.5 ft x 7.5 ft 4 foot 258.30 uW/cm2 53.42 seconds 9.5 ft x 9.5 ft 5 foot 165.31 uW/cm2 1.39 minutes 11.5 ft x 11.5 ft 6 foot 114.8 uW/cm2 2 minutes 13.5 ft x 13.5 ft 7 foot 84.35 uW/cm2 2.72 minutes 15.5 ft x 15.5 ft 8 foot 64.58 uW/cm2 3.56 minutes 17.5 ft x 17.5 ft 9 foot 51.02 uW/cm2 4.50 minutes 19.5 ft x 19.5 ft 10 foot 41.33 uW/cm2 5.56 minutes 21.5 ft x 21.5 ft 12 foot 28.70 uW/cm2 8.02 minutes 25.5 ft x 25.5 ft 15 foot 18.37 uW/cm2 12.52 minutes 31.5 ft x 31.5 ft 18 foot 12.76 uW/cm2 18.04 minutes 37.5 ft x 37.5 ft 20 foot 10.33 uW/cm2 22.26 minutes 41.5 ft x 41.5 ft 22.5 foot 8.16 uW/cm2 28.18 minutes 46.5 ft x 46.5 ft 25 foot 6.61 uW/cm2 34.78 minutes 51.5 ft x 51.5 ft 28 foot 5.27 uW/cm2 43.64 minutes 57.5 ft x 57.5 ft 30 foot 4.59 uW/cm2 50.08 minutes 61.5 ft x 61.5 ft 32.5 foot 3.92 uW/cm2/span> 58.78 minutes 66.5 ft x 66.5 ft 35 foot 3.38 uW/cm2 68.18 minutes 71.5 ft x 71.5 ft 40 foot 2.59 uW/cm2 89.04 minutes 81.5 ft x 81.5 ft 45 foot 2.04 uW/cm2 112.70 minutes 91.5 ft x 91.5 ft 50 foot 1.66 uW/cm2 139.14 minutes 101.5 ft x 101.5 ft *Exposure time is based off of total irradiance. The above calculations are based on 12mJ total exposure. This level of exposure deactivates most organisms. **Distance from cart is surface distance from each side. ***Coverage area is calculated based on the cart being in the center of this area. This coverage area factors in the size of the cart. Please see "Distance from Cart" column for distance from one side of the cart. Voltage: The RNT-IND-UC.360-24-8L-UVC-AT-25CÊoperates on 120 V AC. 5-15 Straight Blade Plug 15 Amp / 125V Rated L5-15 Twist Lock Plug 15 Amp / 125V Rated Flying Leads / Pigtail Wires Wiring/Plug: This unit is equipped with 25 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with ground or NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug. Cart: Operators can easily move the UV lighting system around facilities via four wheels at the bottom. A center rail enables seamless guidance and positioning of the unit. For best results, the light should be setup in the middle of the area. Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Suggested Applications: Sanitation, disinfection, retail spaces, lobbies, commercial locations, industrial parks, schools, public transportation hubs, airports, office buildings, medical centers, and more; kills 99% of viruses, bacteria, mold, and spores. Call 888-325-4448 to place your Larson Electronics order online today!
Larson Electronics IND-UC.360-24-8L-UVC-AT-25C Portable Industrial UV Sanitation Light 1,000 sq.ft. Area - (8) UVC Lamps - Digital Timer - 25' SOOW Cord
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics IND-UC.360-24-8L-UVC-AT-25C Portable Industrial UV Sanitation Light 1,000 sq.ft. Area - (8) UVC Lamps - Digital Timer - 25' SOOW Cord
- SKU:
- IND-UC.360-24-8L-UVC-AT-25C
- UPC:
- Weight:
- 0.00 LBS
!