Made in Texas The Larson Electronics MPD-480D-30AFT-45KVA-2X208.30A-12X120.20A-20C power distribution substation converts 480V AC three phase electrical current into three phase 208Y/120V AC. This unit provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use: The MPD-480D-30AFT-45KVA-2X208.30A-12X120.20A-20C portable power distribution system gives operators the ability to power their 480V, 240V and 120V equipment from a single system. On the primary side, operators connect 480 volt using 20` of Type W Cord and to one L16-30R receptacle for 480V equipment. On the secondary side, operators connect to two L15-30R receptacles for 240V equipment and to twelve 5-20R GFCI receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 20` Type W cord brings 480V three phase power to the NEMA 3R 30-amp, 480V three phase primary disconnect, which contains three 30-amp time delay fuses protecting one 30-amp, 480V, L16-30R receptacle, and passes 480V three phase through to the second primary disconnect. The NEMA 3R 60-amp, 480V three phase second primary disconnect contains three 60-amp time delay fuses and passes 480V three phase power to the transformer. The NEMA 3R 45 KVA transformer converts 480V three phase to 208Y/120V AC three phase and passes the current to the secondary side. The secondary side of the transformer feeds a NEMA 3R 125-amp, 208Y/120V AC three phase main lug only panel. This secondary panel contains two 30-amp, 3-pole, 250V breakers protecting two 30-amp, 250V, L15-30R receptacles, and twelve 20-amp, 1-pole, 125V breakers protecting twelve 20-amp, 125V, 5-20R GFCI receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. This model is equipped with forklift skid pockets, locking casters, and a top located lifting eyelet which allows easy lifting with cable or chain hooks. This can be replaced for an additional cost with stainless steel, hot dip galvanized steel, or aluminum depending on the customers needs. Larger units are available upon request and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MPD-480D-30AFT-45KVA-2X208.30A-12X120.20A-20C Power Distribution Ratings Line-In Cord: 20` Type W Cord Max Primary OCP : 90A @ 480V Line-In Cord Cap: Customer Provided Max PDU OCP : 60A @ 480V Primary Voltage: 480V 3PH Max Secondary Output: 125A @ 208V Primary Disconnect: (1) 30A 480V 3PH Fused @ 30A N3R, (1) 60A 480V 3PH Fused @ 60A N3R UL 1640 Portable Power-Distribution Equipment Primary Panel: - NEMA 3R Indoor / Outdoor Use Primary Breakers: - Made in the USA Primary Receptacles: (1) 30A L16-30R [480V] Primary Protection: Time Delay Fuses, Disconnect Switch Transformer: 45KVA 480V to 208Y/120V 3PH 60 Hz N3R Secondary Voltage: 208Y/120V AC 3PH Secondary Disconnect: - Secondary Panel: 125A 208Y/120V 3PH MLO N3R Secondary Breakers: (2) 30A 3P [250V], (12) 20A 1P [125V] Secondary Receptacles: (2) 30A L15-30R [250V], (12) 20A 5-20R GFCI [125V] Special Orders- Requirements Secondary Protection: Breakers, GFCI, Weatherproof Covers Contact us for special requirements Form Factor: Square tube frame, skid pockets, top pick eye & locking 8 locking casters Phone: 1-214-616-6180 Frame Materials: Powder coated steel frame Toll Free: 888-325-4448 Dimensions: 34 X 44 X 58 Fax: 1-903-498-3364 Weight: 600 pounds E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase
Larson Electronics 45 KVA Power Distribution Panel - 480V to 208Y/120V 3PH - (1) L16-30R, (2) L15-30R, (12) 5-20R GFCI
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics 45 KVA Power Distribution Panel - 480V to 208Y/120V 3PH - (1) L16-30R, (2) L15-30R, (12) 5-20R GFCI
- SKU:
- MPD-480D-30AFT-45KVA-2X208.30A-12X120.20A-20C
- UPC:
- Weight:
- 0.00 LBS
!