Made in the USA The Larson Electronics MGS-480FT30A-30KVA-6X120-2X240 heavy duty power transformer substation converts 480V AC three phase electrical current to 208Y/120V three phase. This unit provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The MGS-480FT30A-30KVA-6X120-2X240 portable power distribution system gives operators the ability to power their 480 volt, 250 volt and 120 volt equipment from a single system. On the primary side, operators connect 480 volt line-in power using 20` of #6 Type W cord to one L16-30R receptacle for 480V equipment. On the secondary side, operators connect to two L6-30R receptacles for 250V equipment and to six duplex GFCI receptacles for 120V equipment. A 20` #6 Type W cord brings 480V three phase power to the NEMA 3R 30-amp, 480V three phase primary disconnect, which is fused at 30 amps and contains one 30-amp, 480V, L16-30R receptacle, and passes 480V three phase through to a second disconnect on the primary side. This second 60-amp, 480V primary disconnect, which is fused at 50 amps, passes 480V three phase to the transformer. The NEMA 3R 30 KVA transformer converts 480V three phase power to 208Y/120V three phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 72.2-amp, 240D/120V three phase main lug only panel. This secondary panel contains two 30-amp breakers protecting two 30-amp, 250V, L6-30R receptacles, and six 20-amp breakers protecting six 20-amp, 120V duplex GFCI receptacles. All receptacles are equipped with weatherproof covers. The transformer and distribution assembly is mounted onto a rugged frame constructed of 2" square carbon steel with 3" X 6" X 3/8" tubular carbon steel skid pockets and a top located lifting eyelet to allow easy transport. All terrain 23" tall by 7.5" trailer tires provide easy mobility around the workplace without the need for mechanical lifting devices. The steel skid is mounted to two trailer axles with 16" steel trailer rims. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGS-480FT30A-30KVA-6X120-2X240 Power Substation Ratings Line-In Cord: 20` #6 Type W Cord Max OCP Primary: 60A @ 480V Line-In Cord Cap: Customer Provided Max OCP Secondary: 72.2A @ 240D Primary Voltage: 480V 3PH NEMA 3R Indoor or Outdoor Use Primary Disconnect: 480V 30A Fused @ 30A N3R, 480V 60A Fused @ 50A N3R Made in the USA Primary Panel: - UL 1640 Portable Power-Distribution Equipment Primary Breakers: - Primary Receptacles: (1) L16-30R [480V] Primary Protection: Weatherproof Cover, Disconnects Transformer: 30 KVA 480V to 208Y/120V 3PH N3R Secondary Voltage: 208Y/120V 3PH Secondary Panel: 240D/120V 72.2A MLO N3R Secondary Breakers: (2) 30A, (6) 20A Secondary Receptacles: (2) 30A L6-30R [250V], (6) 20A Duplex GFCI [120V] Secondary Protection: GFCI, Weatherproof Covers Special Orders- Requirements Form Factor: Square tube frame w/ 1/4" thick, 3" tubing, skid pockets, top pick eye & 8 locking casters Contact us for special requirements Frame Materials: Powder coated steel frame Toll Free: 888-325-4448 Dimensions: - Weight: 350 pounds E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase
Larson Electronics 30 kVA Power Distribution Station - 480V to 208Y/120V (1) L16-30R (2) L6-30R (6) Duplex GFCI
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics 30 kVA Power Distribution Station - 480V to 208Y/120V (1) L16-30R (2) L6-30R (6) Duplex GFCI
- SKU:
- MGS-480FT30A-30KVA-6X120-2X240
- UPC:
- Weight:
- 0.00 LBS
!