Fluke Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads

Fluke

$774.99
(No reviews yet) Write a Review
SKU:
FLUKE-Solar-Tools-393
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke Solar Tools Kit with 393 FC Clamp Meter and Solar Test Leads

The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. The inline capabilities of the MC4 PVLEAD3 leads allow the system to remain online and generating power while testing without needing to pierce the line.

Key functions of the solar clamp meter and MC4 test leads:

  • View voltage and current simultaneously with the meter's dual display
  • IP54 rated meter, ideal for work outdoors including PV panel testing
  • DC power measurement, showing readings in kVA
  • Logging and reporting of test results via Fluke Connect software
  • MC4 leads comply to IEC / EN 61010-031


Key features

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Sturdy IP54 rated for outdoor use and solar arrays
  • Work efficiently with dc power measurement, audio polarity and visual continuity
  • MC4 test lead sets are designed for use with solar clamp meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V



Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

GeneralÊÊÊ
Maximum voltage between any Terminal and Earth GroundÊÊ
AC1000 VÊÊ
DC1500 VÊÊ
Batteries2 AA IEC LR6 alkalineÊÊ
DisplayDual display with backlightÊÊ
Automatic Power Off20 minutesÊÊ
ElectricalÊÊÊ
AccuracyÊÊÊ
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 ¡C to 28 ¡C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature CoefficientsAdd 0.1 x specified accuracy for each ¡C > 28 ¡C or < 18 ¡C
AC Current: JawÊÊÊ
Range999.9 AÊÊ
Resolution0.1 AÊÊ
Accuracy2 % + 5 digits (10 Hz to 100 Hz)Ê
Ê2.5 % + 5 digits (100 Hz to 500 Hz)Ê
Crest Factor (50/60 Hz)2.5 @600.0 AÊÊ
Ê3.0 @500.0 AÊÊ
Ê1.42 @999.9 AÊÊ
ÊAdd 2 % for C.F. >2ÊÊ
AC Current: Flexible Current ProbeÊÊÊ
Range999.9 AÊÊ
Ê2500 AÊÊ
Resolution0.1 A (²999.9 A)ÊÊ
Ê1 A (²2500 A)ÊÊ
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz)Ê
Crest Factor (50/60Hz)2.5 @1400 AÊÊ
Ê3.0 @1100 AÊÊ
Ê1.42@2500 AÊÊ
ÊAdd 2 % for C.F. >2ÊÊ
Position SensitivityÊÊÊ
NEC symbol
Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
ÊÊÊÊ
DC CurrentÊÊÊ
Range999.9 AÊÊ
Resolution0.1 AÊÊ
Accuracy2 % RD + 5 digits[1]ÊÊ
Ê[1] When using the ZERO (B) function to compensate for offsets.
AC VoltageÊÊÊ
Range600.0 VÊÊ
Ê1000 VÊÊ
Resolution0.1 V (²600.0 V)ÊÊ
Ê1 V (²1000 V)ÊÊ
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz)Ê
DC VoltageÊÊÊ
Range600.0 VÊÊ
Ê1500 VÊÊ
Resolution0.1 V (²600.0 V)ÊÊ
Ê1 V (²1500 V)ÊÊ
Accuracy1 % RD + 5 digitsÊÊ
mV dcÊÊÊ
Range500.0 mVÊÊ
Resolution0.1 mVÊÊ
Accuracy1 % RD + 5 digitsÊÊ
Amps Frequency: JawÊÊÊ
Range5.0 Hz to 500.0 HzÊÊ
Resolution0.1 HzÊÊ
Accuracy0.5 % RD + 5 digitsÊÊ
Trigger Level5 Hz to 10 Hz, ³10 AÊÊ
Ê10 Hz to 100 Hz, ³5 AÊÊ
Ê100 Hz to 500 Hz, ³10 AÊÊ
Amps Frequency: Flexible Current ProbeÊÊÊ
Range5.0 Hz to 500.0 HzÊÊ
Resolution0.1 HzÊÊ
Accuracy0.5 % RD + 5 digitsÊÊ
Trigger Level5 Hz to 20 Hz, ³25 AÊÊ
Ê20 Hz to 100 Hz, ³20 AÊÊ
Ê100 Hz to 500 Hz, ³25 AÊÊ
Voltage FrequencyÊÊÊ
Range5.0 Hz to 500.0 HzÊÊ
Resolution0.1 HzÊÊ
Accuracy0.5 % RD + 5 digitsÊÊ
Trigger Level5 Hz to 20 Hz, ³5 VÊÊ
Ê20 Hz to 100 Hz, ³5 VÊÊ
Ê100 Hz to 500 Hz, ³10 VÊÊ
DC PowerÊÊÊ
Range600.0 kVA (600.0 V dc range)ÊÊ
Ê1500 kVA (1500 V dc range)ÊÊ
Resolution0.1 kVAÊÊ
Ê1 kVAÊÊ
Accuracy2 % RD + 2.0 kVAÊÊ
Ê2 % RD + 20 kVAÊÊ
ResistanceÊÊÊ
Range600.0 ½ÊÊ
Ê6000 ½ÊÊ
Ê60.00 k½ÊÊ
Resolution0.1 ½ (²600.0 ½)ÊÊ
Ê1 ½ (²6000 ½)ÊÊ
Ê0.01 k½ (²60.00 k½)ÊÊ
Accuracy1 % RD + 5 digitsÊÊ
CapacitanceÊÊÊ
Range100.0 _FÊÊ
Ê1000 _FÊÊ
Resolution0.1 _F (²100.0 _F)ÊÊ
Ê1 _F (²1000 _F)ÊÊ
Accuracy1 % RD + 5 digitsÊÊ
Inrush Trigger Level5 AÊÊ
MechanicalÊÊÊ
Size (L x W x H)281 mm x 84 mm x 49 mmÊÊ
Weight (with batteries)520 gÊÊ
Jaw Opening34 mmÊÊ
Flexible Current Probe Diameter7.5 mmÊÊ
Flexible Current Probe Cable LengthÊÊÊ
(head to electronics connector)1.8 mÊÊ
EnvironmentalÊÊÊ
Operating Temperature-10 ¡C to 50 ¡CÊÊ
Storage Temperature-40 ¡C to 60 ¡CÊÊ
Operating HumidityNon condensing (<10¡C)ÊÊ
ʲ90 % RH (at 10 ¡C to 30 ¡C)ÊÊ
ʲ75 % RH (at 30 ¡C to 40 ¡C)ÊÊ
ʲ45 % RH (at 40 ¡C to 50 ¡C)ÊÊ
Operating Altitude2000 mÊÊ
Storage Altitude12 000 mÊÊ
Ingress Protection (IP) RatingIEC 60529: IP54 non-operatingÊÊ
Electromagnetic Compatibility (EMC)ÊÊÊ
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
ÊGroup 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
ÊClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
SafetyÊÊÊ
GeneralIEC 61010-1, Pollution Degree 2Ê
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 VÊ
ÊIEC 61010-2-033: CAT III 1500 V / CAT IV 600 VÊ
Wireless RadioÊÊÊ
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLEÊ
Wireless Radio Frequency Range2400 MHz to 2483.5 MHzÊÊ
Output Power<100 mWÊÊ
SIMPLIFIED EU DECLARATION OF CONFORMITYÊÊ
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:ÊÊ
www.fluke.com/en-us/declaration-of-conformityÊÊÊ



Specifications: Pomona PVLEAD1 and PVLEAD3 MC4 Solar Clamp Test Lead Set

ÊPVLEAD1PVLEAD3
MC4 to 4mm Test Lead SetMC4 Solar Clamp Meter Test Lead Set
ContactBrass, Nickel PlatedBrass, Nickel Plated
Length60Ó36Ó, 12Ó
VoltageCAT III 1000V,CAT III 1000V,
CAT IV 600VCAT IV 600V
Current20 amp20 amp
StandardsIEC 61010-031IEC 61010-031

Reviews