Fluke 190 Series III ScopeMeter¨ Test Tools

Fluke

$3,965.99
(No reviews yet) Write a Review
SKU:
FLUKE-190-Series-Iii
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke 190 Series III ScopeMeter¨ Test Tools

Fluke Premium Care eligible

When you invest in Fluke 190 Series III ScopeMeter¨_ Test Tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the 190 Series III original product warranty, so you donÕt need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

High performance portable oscilloscopes engineered for harsh environments

Fluke 190 Series III ScopeMeter¨ Test Tools are engineered to go where you go, and tackle just about any troubleshooting job along the way. These CAT III 1000 V/CAT IV 600V rated test tools combine rugged portability with the high performance of bench oscilloscopes to help you take on the challenges of installing, commissioning and maintaining industrial machinery, automation and process controls, and power conversion electronics with easeÑfrom DC to 500 MHz.

Choose from two or four channel models with a wide range of bandwidth options. Fast sampling rates up to 5.0 GS/s, 200 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and display of waveform details, noise, and other disturbances. Perform timing or amplitude related measurements on three phases or three-axis control systems, or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot Paperless Recorder, ScopeRecord Mode, Connect-and-View Triggering and a unique 100-screen Replay function help you quickly diagnose issues to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, induced noise, intermittent events and signal fluctuations or drift.

  • Up to four independent floating isolated inputs, up to 1000 V
  • Up to 5 GS/s real time sampling (depending on model and channels used)
  • Deep memory: 10,000 points per trace waveform capture (scope mode)
  • CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments
  • Up to seven hours of battery operation using BP291
  • Large, bright color display is easy to view in nearly any environment
  • Easy to store and view historical data and transfer to a PC via USB or Wifi
  • Convenient battery access door for quick battery swaps in the field
  • IP51 rating, dust and drip-proof
  • Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals
  • Frequency spectrum using FFT-analysis
  • Automatic capture and REPLAY of 100 screens
  • ScopeRecord mode gives 30,000 points per input channel for low frequency signal analysis
  • TrendPlot Paperless Recorder mode with deep memory for long- term automatic measurements
  • 5,000 count DMM included in the 2-channel models

Measure from mV to kV safely

Independently isolated inputs allow you to make measurements in mixed circuits having different ground references reducing the risk of accidental short circuits. Conventional bench oscilloscopes without special differential probes and isolation transformers can only reference measurements to line power earth ground. ScopeMeter 190 Series III test tools are engineered to cover a wide application range from mV to kV, so youÕre ready for anything from microelectronics to heavy-duty higher voltage electrical applications. 190 Series III 60MHz and 100MHz configurations include VPS421 100:1 probes for higher voltage applications, while the 200MHz and 500MHz configurations include VPS410-II 10:1 probes suitable for both microelectronics and higher voltage applications.

IP-51 rated for harsh environments

Rugged and shock-proof, ScopeMeter Test Tools are built for dirty, hazardous environments. With its sealed case, it can endure dust, drips, humidity and airborne pollutants. Every time you reach for ScopeMeter Test Tool you can be confident it will work reliably wherever your work takes you.

USB and Wi-Fi connectivity

The Fluke 190 Series III offers two USB ports, electrically isolated from measurement input circuits allowing you to quickly and easily transfer data to a PC, archive and share waveforms with OEMs, colleagues and support staff, or store waveforms, screen captures and instrument setups onto USB memory devices for later use. Easily transfer saved files via USB stick, direct connection via the USB interface or optional Wi-Fi connectivity. These files can be used for further data handling or in FlukeView-2 Software to study waveforms in greater detail.

Connect-and-View triggering

Connect-and-View triggering provides an instant, stable display without the need for adjusting set- tings. If youÕve used other scopes, you know how tricky triggering can be. If settings are incorrect, results can be unstable or incorrect. Connect-and-View automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable and repeatable display of virtually any signal including motor drive and control signals. ItÕs especially fast and convenient when youÕre measuring a number of test points in rapid succession.

Connect and View captures even the most complex signals without requiring additional setup
The built-in multimeter provides convenient precision measurements

Built-in digital multimeter

Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter on two channel 190 Series III models. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors.

ScopeRecord mode for high resolution waveform recording

ScopeRecord memory stores up to 30,000 or more data points per channel, capturing fast intermittent events and glitches as short as 8 ns. (Two sets of multiple channel recordings can be stored to internal memory for later analysis.)

  • Records events like UPS, power supply or motor start-up cycles
  • With the Stop on Trigger mode, the ScopeMeter Test Tool automatically recognizes a power failure and stores the waveform data preceding it
Capture high-resolution waveform details over extended period using ScopeRecord mode
Trend multiple measurements capturing signal intermittent events, signal drift or fluctuations

TrendPlot paperless recorderÑ records up to 11 days to help you find intermittent faults

The toughest faults to find are those that happen only once in a while. These intermittent events can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, dips, swells and interruptions, or the starting and stopping of a motor can also cause a machine to stop. You may not be around when it happens, but the Fluke 190 Series III ScopeMeter Test Tool will be.

  • Plot minimum and maximum peak values and average over time
  • Plot any combination of up to four readings including voltages, amps, temperature, frequency and phase for all inputs, all with time and date stamp to pinpoint faults

FlukeView 2 ScopeMeter software for documenting, archiving and analysis

Get more out of your ScopeMeter Test Tool with FlukeView 2 ScopeMeter Software for Windows.

  • DocumentationÑtransfer waveforms, screens and data to your PC for printing or importing data into a report
  • Add text to ScopeMeter Test Tool settingsÑgive operators guidance when recalling settings
  • ArchiveÑcreate a library of waveforms for easy reference, or waveform comparison
  • AnalysisÑuse cursors or export data to another analysis program
FlukeView-2 ScopeMeter software


Key features

  • Rated for industrial environments CAT III 1000 V/CAT IV 600 V
  • Automatically capture, view and analyze complex waveforms
  • Large, bright color display for easy in-the-field viewing
  • USB and Wi-Fi download for analyzing data with FlukeView¨ software
  • Up to four independent floating isolated inputs, up to 1000 V


Oscilloscope Models
 190-062190-102190-202190-502190-104190-204190-504
Vertical deflection
Number of channels2222444
Bandwidth60 MHz100 MHz200 MHz500 MHz100 MHz200 MHz500 MHz
Rise time5.8 ns3.5 ns1.7 ns0.7 ns3.5 ns1.7 ns0.7 ns
Number of scope inputs2 input channels plus external trigger4 input channels
Channel architectureAll inputs fully insulated from each other and from ground. Inputs may be activated in any combination.
Input couplingAC or DC, with ground level indicator
Input sensitivityWith 10:1  probe, 20 mV  to 1000 V/div
With 100:1  probe, 200 mV to 10 kV/div
Direct (1:1),  2 mV  to 100 V/div
Bandwidth limiter20 MHz and 10  kHz
PolarityNormal,  Inverted, Variable
Input voltageCAT III 1000 V/CAT IV 600 V rated, see General specifications for further details
Vertical resolution8 bit
Accuracy at 4 s to 10 _s/div5 mV/div to 100 V/div, ±(1.5 % + 6 counts)
2 mV/div, ±(1.5  % + 10 counts)
Input impedance1 M½ (± 1 %) //  15  pF (± 2.25  pF)
Horizontal
Maximum real- time sample rate (sampled simultaneously)625 MS/s
(each channel)
1.25 GS/s (each channel)2.5 GS/s (each channel)5 GS/s (single channel) or
2.5 GS/s (dual channel)
1.25 GS/s (each channel)2.5 GS/s (2ch)
1.25 GS/s (4ch)
5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch)
Record lengthUp to 10,000 samples per  channel
Time base range10 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord Roll mode (see ÔRecorder modeÕ)
Maximum record length10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord Roll mode (see ÔRecorder modeÕ)
Timing accuracy± (0.01 % of reading + 1  pixel)
Glitch capture8 ns (10  µs/div to 2 min/div)
Display and acquisition
Display133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD
Display modesAny combination of channels; average on/off; replay.
Visible screen width12  divisions horizontally in scope mode
Digital persistence modesOff, short, medium, long, infinite and envelope mode
Waveform mathematicsOne (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT
Acquisition modesNormal, Averaged, Auto, Single Shot, ScopeRecord roll, glitch capture, waveform compare with automatic ÒPass/Fail testingÓ; Replay
Trigger and delay
SourceInput A, B or External (via meter input)Input A, B, C or  D
ModesAutomatic, Edge, Pulse Width, N-Cycle, External (190-xx2)
Connect-and- ViewAdvanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts  triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Pulse width triggering (on channel A)Pulse width qualified by time
Allows for triggering <t, >t, =t, ­ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggeringTriggers on both rising and falling edges alike
N-cycle triggeringTriggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screensÑno specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in Òbaby-sitÓ mode capturing 100 specified events.
ReplayManual or continuous replay. Displays the captured 100 screens as a ÒliveÓ animation, or under manual control. Each screen has date and time-stamp.
Replay storageTen sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFTÑfrequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
WindowAutomatic, Hamming, Hanning or None
Automatic windowDigitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant.
Vertical scaleLinear/Logarithmic (in volts or amps)
Frequency axisFrequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform compareProvides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope.
Pass/Fail testingIn waveform compare mode, the oscilloscope can be set up to store only matching (ÒPassÓ) or only non-matching (ÒFailÓ) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA  reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature ¡C, temperature ¡F (not for Japan), dBV, dBm into 50 ½ and 600 ½, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio;
Advanced power and motor drive functionsV/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters
Cursor measurements
SourceOn any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal linesVoltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical linesTime between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors.
Single vertical lineMin-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
Advanced functionsmA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors)
ZOOMRanges from full record overview to zoom in up to sample level, at any record length.
 
Meter modes
 190-062190-102190-202190-502190-104190-204190-504
Meter inputsVia 4 mm banana inputs, fully isolated from scope inputs and scope groundVia BNC scope inputs
Number of readingsOne at a time via DMM inputUp to 4 automatic scope measurements simultaneously
Maximum resolution5,000 counts± 999 counts
(frequency: 9999 counts)
Input impedance1 M½ (± 1 %) // 14 pF (± 1.5 pF)1 M½ (± 1 %) // 15 pF (± 2.25 pF)
Advanced meter functionsAuto/manual ranging, relative measurements (Zero reference), TrendPlot recording
 The specified accuracy is valid over the temperature range 18 ¡C to 28 ¡C Add 10 % of specified accuracy for each degree C below 18 ¡C or above 28 ¡C
Voltage
V dc accuracy± (0.5 % + 6 counts)± (1.5 % + 6 counts)
V ac true rms accuracy
15 Hz to 60 Hz± (1 % + 10 counts)± (1.5 % + 10 counts)
60 Hz to 1 kHz± (2.5 % + 15 counts)Ñ
60 Hz to 20 kHzѱ (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz± (1 % + 10 counts)± (1.5 % + 10 counts)
60 Hz to 1 kHz± (2.5% + 15 counts)Ñ
60 Hz to 20 kHzѱ (2.5 % + 15 counts)
Voltmeter ranges500 mV, 5 V, 50 V, 500 V, 1,100 V 
Resistance
Ranges500 ½, 5 k½, 50 k½, 500 k½, 5 M½, 30 M½Ñ
Accuracy± (0.6 % + 6 counts)Ñ
Other meter functions
ContinuityBeeper on < 50 ½ (± 30 ½)Ñ
Diode testUp to 2.8 VÑ
Current (A)A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
TemperatureWith optional accessories. Scale factors 1mV/¡C or 1mV/¡F
 
Recorder mode
 190-062190-102190-202190-502190-104190-204190-504
ScopeRecord Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and displayInput A, Input B,  Dual
All channels sampled simultaneously
Any combination of inputs, up to 4 channels.
All channels sampled simultaneously
Memory depth30,000 data points per channel, each holding min/max pair of information
Min/max valuesMin/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches.
Recording modesSingle sweep, continuous roll; Start-on-Trigger (through external); Stop-on-Trigger (through external)Single sweep, continuous roll; Start-on-Trigger (through any channel); Stop-on-Trigger (through any channel)
Stop-on-triggerScopeRecord mode can be stopped by an individual trigger event, or by an interruption
of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scaleTime from start, time of  day
ZoomRanges from full record overview to zoom in up to sample level
MemoryTwo multiple input ScopeRecord waveforms can be saved internally for later recall and analysis.
ScopeRecord Roll mode sample rate and recording timespan
Time base range4 ms/div to 2 min/div
Recorded timespan4.8 sec to 40 hr
Time/division in Ôview allÕ mode0.4 s/div to 4 h/div
Glitch capture8 ns
Sample rate125 MS/s
Resolution160 _sec ~ 4.8 sec
Trendplot Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and displayAny combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp.
RangesNormal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time spanUp to 22 days, with a resolution of 102 seconds; up to 5.5 days for 4 readings.
Recording mode