Leviton O2C15-IDW Occupancy Sensor with Integrated Photocell, Line Voltage, Dual Relay, PIR, Ceiling Mount, 1500SF, 120-277V, Extended Range Lens installed, Mid-Range included, Provoltª

Leviton

(No reviews yet) Write a Review
SKU:
LEVITON-O2C15-IDW
Weight:
0.00 LBS
Call for price
Leviton O2C15-IDW Occupancy Sensor with Integrated Photocell, Line Voltage, Dual Relay, PIR, Ceiling Mount, 1500SF, 120-277V, Extended Range Lens installed, Mid-Range included, Provoltª

Occupancy Sensor with Integrated Photocell, Line Voltage, Dual Relay, PIR, Ceiling Mount, 1500SF, 120-277V, Extended Range Lens installed, Mid-Range included, Provoltª

Occupancy Sensor with Photocell, Provoltª lighting control, 2 Pole, Line Voltage, 8'-12' Ceiling Mount, Passive Infrared, Daylighting, Auto-Calibration, 1500 sq ft, 120-277V AC/CA 50/60HZ. UL/CE, RoHS & CEC Title 20/24 compliant. Color: White.

The Leviton Provoltª Series combine line voltage occupancy sensors and photocells into a self-contained unit. The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low-cost, efficient energy solution for new construction and retrofits.

Do you have a question about an
occupancy sensor or vacancy sensor?

Contact us to learn more. 



  • Uses industry-exclusive digital (4 element) PIR circuitry for fewer false triggers from unwanted sources such as HVAC systems. A Fresnel lens establishes dozens of detection zones requiring the heat source to move from one zone to another to trigger the sensor.
  • Auto-Adapting: Time delay and sensitivity are continually adjusted to occupancy pattern of use
  • Configurable for Manual ON/Auto OFF or Auto ON/Auto OFF
  • Delayed OFF Timer: The sensor will turn lights OFF if no motion is detected after a specified time
  • Exclusive Walk-through Feature: Provides increased energy savings by not leaving the lights ON for an extended period after only momentary occupancy
  • False Detection Timer: (M/T) The PIR scans for movement and shuts lights off after 31 minutes preventing false triggers from HVAC systems
  • Output short circuit protection
  • Industry-exclusive self-configuring local manual switch input: Momentary or maintained switches are supported
  • Presentation Mode feature for slide or film presentations allows push buttons to turn lights OFF and keep them OFF while the room is occupied
  • Adjustable Time Delay: 30s, 5min, 10min, 20min, 30min
  • Test Mode for simplified commissioning
  • Manual Switch and Emergency Override are Class 1 and Class 2 circuits. Class 2 circuits provided for flexibility
  • Industry-exclusive Òfail-safeÓ circuitry: In the event of product failure, Return-to-Closed feature causes the relay to default ON which eliminates life safety concerns
  • Industry-exclusive H.I.S. (High Inrush Stability) technology designed to handle todayÕs high inrush electronic ballast loads and offer unmatched durability and service
  • Robust and reliable mechanically held 10A latching relay provides dependability and robust performance for all load types and provides energy savings over electronically held relays
  • Lenses are easily replaceable and color-coded blue (high-density) and red (mid-range) for contractors and end-users to easily identify lenses from the ground: Red Visual LED indicator - Blinks when infrared is detecting motion and during photocell manual calibration; solid during device malfunction, Yellow Visual LED indicator - Blinks during test mode; solid with emergency/BMS input, Blue Visual LED indicator - Blinking light indicates photocell override


Product Features
Application: Code Compliance, Auto ON/Auto OFF, Manual ON/Auto OFF, Fan Control, Auto ON/Manual ON, Stairwell Control, Step dimming
Color: White
Feature: PIR Line Voltage Dual Relay
Grade: Commercial
Mounting: Ceiling Mount
Product Line: Provolt
Sensor Technology: Passive Infrared (PIR)
Sensor Type: Occupancy, Photocell
Time Delay: 30s-30m
Title 24 Compliant: Yes

Performance Specifications
Coverage (Sq.Ft.): 1500
Pattern: 360¡

Electrical Specifications
Current Consumption: 60-30mA
Frequency: 50/60Hz
Load Rating: 120V, 50/60Hz: 8A, Electronic Ballast, 800W, Tungsten, 800VA Ballast, 1/4 HP Motor - 230V, 50Hz: 6A/6AX, Electronic Ballast, Magnetic Ballast, Tungsten, 1/3 HP Motor - 277V, 50/60Hz: 5A, Electronic Ballast, 1200VA Ballast, 1/3 HP Motor
Neutral Wire Connection: Required
Voltage: 120/230/277 VAC

Standards and Certifications
Listings: Can be used to comply with ASHRAE 90.1 and California Title 24, Part 6 occupancy/vacancy sensing, automatic shut-off, daylight harvesting and stairwell requirements, UL 773A (Occupancy Standard), UL 924 (Emergency Equipment), cUL listed, CE compliant, NOM certified, RoHS compliant, NY LLC48 compliant

Mechanical Specifications
Mounting Type: Ceiling Mount
Relay Type: Dual Relay
Size: Width 4.81" (122.21mm), Depth 2.39" (60.71mm)

Environmental Specifications
Operating Temperature: 32¡ to 104¡F (0¡ to 40¡C)
Relative Humidity: 0% to 90% non-condensing
Storage Temperature Range: -15¡ to 160¡F (-26¡ to 71¡C)

Type
Product Type: Occupancy Sensor and Photocell

Warranty
Warranty: 5-Year Limited