Image coming soon

Larson Electronics *RENTAL* Explosion Proof Light -50 Watt - Class 1 Division 1 - 50' Inline transformer 120/240V-12V

Larson Electronics

(No reviews yet) Write a Review
SKU:
RNT-EPL-50W-120x12-50
Weight:
0.00 LBS
Call for price
Made in the USA This unit is for rentals The Larson Electronics RNT-EPL-50W-120x12-50 Hazardous Area Incandescent Work light is approved for Class 1 Division1 Groups C and D, meets federal specification JC-580A, and is idea for commercial and industrial work and inspection activities within hazardous locations requiring explosion proof protection. This 50 watt explosion proof incandescent work light from Larson Electronics meets federal specification JC-580A and comes complete 50 foot of 16/3 SOOW cord and an inline transformer that steps down high voltage 120/240 volts to 12 Volts. This hazardous location hand lamp is designed with an explosion proof slip-ring housing and is Class 1 Division 1 Groups C and D hazardous location environment approved. 40` Container Dark Illuminated by RNT-EPL-50W-120x12-50 Picture provided so that user may see the beam in action at first 40` from source. This 50 watt fluorescent light is suitable for use in areas where petrochemical vapors and various flammable chemicals are present and projects a strong light beam with good peripheral illumination and a well defined central spot beam. This light is designed to produce a far reaching spot beam which makes it ideal for use in larger hazardous locations where a strong beam is needed to reach hard to access areas for inspections. This handlamp has the transformer mounted inline with the 50 foot of SOOW cord for convenient and simple setup. Transformer & Voltage: This unit is equipped with encapsulated step down transformer that automatically monitor and adjust input current to maintain the correct voltage levels regardless of input levels across a specific range. These explosion proof drop lights can operate on current ranging from 90 to 305V AC or 127 to 431V DC without any modifications necessary as a result. This ability to sense and adjust input current also provides protection against voltage spikes and drops that can occur in electrical systems. Click Photos to Enlarge 5-15 Straight Blade Plug15 Amp / 125V Rated L5-15 Twist Lock Plug15 Amp / 125V Rated L6-15 Twist Lock Plug15 Amp / 250V Rated UK BS1363 Straight Blade Plug13 Amp / 250V Rated / Internal Fuse Intl Schuko 2-Pin Plug16 Amp / 250V Rated / Grounded Flying Leads / Pigtail Wires Wiring and Plug: This explosion proof drop light is equipped with 50` of 16/3 chemical and abrasion resistant SOOW cord, and inline step-down transformer, and 5` of SOOW cable that is fitted with an industrial grade cord cap for easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with ground, standard 6-15 15 amp straight blade plug for 220-240V outlets with ground, NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets, NEMA L6-15 15 amp twist lock plug for 240V twist lock outlets, British BS1363 13 amp fused 3-blade plug for United Kingdom outlets, or a two pin 16 amp rated Schuko plug with ground contact and socket for European outlets up to 250V. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug. Cross for Chambers Power Products HEP305S-50. Specifications / Additional Information RNT-EPL-50W-120x12-50 Work Light Ratings/Approvals Listing: United States Class 1, Division 1 for Groups C, D Lamp Type: Incandescent JC-580A Compliant Voltage: 100-277 Volts AC, 50/60Hz or 127-431V DC Total Watts: 50 watts View the Explosion Proof Light Design Description Lux: At Lens: 200,000 Lux: At 1 Meter: 55,000 Mounting: Non Sparking Alloy Hook Special Orders- Requirements Wiring: 50` 16/3 SOOW, inline transformer, 5` 16/3 SOOW Contact us for special requirements Cord Cap: 5-15, 6-15, L5-15, L6-15, BS1363, Schuko, or Pigtail Toll Free: 888-325-4448 Rental Type: Monthly, Weekly, Daily Warranty: Yes - 3 Years E-mail: [email protected] Rentals: In an effort to cut back on contracts and various other paper work, Larson Electronics processes rentals like purchases until the product is returned. (Rent to Own Rates) This means, we will charge the customer for the product total and credit back the difference once the fixture is returned. Weekly and Monthly terms are available. Customer must pay shipping to and from the destination. Please contact us at (903) 498-3363 for further information if required. Rental Prices for the RNT-EPL-50W-120x12-50;;Monthly...$236.69 USDWeekly...$189.35 USD Subtract rental cost from total cost for the amount that will be credited back to customer upon return of product. Customer can choose to convert their rental to a purchase at any time during the rental period. When returned, deductions will also be made for shipping, repairs, and excessive cleaning, if needed. Scroll Down to Purchase- Same Day Shipping Available on This Light!

Reviews