Larson Electronics Class I Division 2 Power Distribution - 9KVA - (1) 240V 30A IEC 60309 Explosion Proof Receptacle

Larson Electronics

(No reviews yet) Write a Review
SKU:
EP-MGL-600-9K-240.120-1X30A-100
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics EP-MGL-600-9K-240.120-1X30A-100 hazardous location power distribution system is designed for operators to power their three phase 240 volt tools and equipment within Class I, Division 2/Class I, Zone 1 rated areas. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION SYSTEMS OR SUBSTATIONS* This system is mounted on a square aluminum tube dolly cart with wheels, providing the portability required to position the unit near a 600V power source. Operators can use a 100-foot 10/4 SOOW line-in cable with a three phase, four wire 63-amp IEC 60309 Class I, Division 2/Class I, Zone 1 rated cord cap to connect to grid or generator power. The line-in cable is terminated in a 600V Class I, Division 2/Class I, Zone 1 three phase, three pole non-fused disconnect. The disconnect protects a 9KVA Class I, Division 1 600V-240V/120 transformer. The transformer feeds a Class I, Division 1 transformer box, containing a 30-amp breaker. The breaker protects a single Class I, Division 2/Class I, Zone 1 240V 30-amp IEC 60309 receptacle. This power distribution system is designed for indoor and outdoor use in hazardous location areas for shipyard, plant maintenance and construction applications. Larson Electronics is a manufacturer of power distribution systems and can custom build power distribution systems to your requirements. If this unit does not meet your needs please contact 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information EP-MGL-600-9K-240.120-1X30A-100 Explosion Proof Power Distribution Ratings Line In: 100` 10/4 SOOW cord Made in the USA Cord Cap: 63A IEC 60309 C1D2 Class I Division 2, Groups C & D Primary Disconnect: 600V, 3-Phase, 3-Pole Non-fused Disconnect C1D2 Class I, Zone 1 & 2, AEx de IIC Transformer: 9KVA 600V-240V/120 C1D1 Conforms to UL 1640 Transformer Box: C1D1 Transformer Box Breakers: (1) 30A 240V Transformer Box Receptacles: (1) 240V 30A IEC 60309 C1D2 Form Factor: Powder coated, aluminum tubing dolly cart with run-flat wheels Special Orders- Requirements Dimensions: 40”W X 40”D X 48”H Contact us for special requirements Weight: 725 pounds Toll Free: 888-325-4448 Max Primary OCP: 63A @ 600V Max Secondary OCP: 30A @ 240V E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews