Larson Electronics 50 Watt Class 1 Division 2 LED Fixture for Hazardous Location Lighting - 6 Foot Low Profile Light

Larson Electronics

(No reviews yet) Write a Review
SKU:
HAL-72-50W-LED
Weight:
0.00 LBS
Call for price
Buy American Compliant The Larson Electronics HAL-72-50W-LED is a low voltage hazardous location lighting solution approved for Class I Division 2 environments and UL 1598 listed for use in wet locations. This powerful 72" long LED strip light produces 3624 lumens, operates from 12 or 24V DC, and is suitable for a variety of applications. The HAL-72-50W-LED is designed to provide a high output and ruggedly durable lighting solution for applications where Class I Division 2 compliance is required. This low voltage explosion proof light can be operated with either 12 or 24 volt DC current and includes 6 feet of connecting lead with standard two wire configuration. This light is constructed of powder coated extruded aluminum for excellent strength and durability and is rated IP54 for protection against exposure to splashing water and limited dust ingress. These units are configured in a 72" long strip or "bar" profile for installation in locations where wide dispersal and a low profile is preferred. The high output, cool running operation, and good color rendering properties of this light make it an ideal replacement for older, bulkier, and less reliable HID and halogen light fixtures. LED Benefits: Unlike gas burning and arc type lamps that have glass bulbs, LEDs have no filaments or fragile housings to break during operation and/or transportation. Instead of heating a small filament or using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current is applied, providing instant illumination with no warm up or cool down time before re-striking. Because there is no warm up period, this light can be cycled on and off with no reduction in lamp life. LED lights run at significantly cooler temperatures than traditional metal halide and high pressure sodium lights and contain no harmful gases, vapors, or mercury, making them both safer and more energy efficient. No extra energy is wasted in cooling enclosed work areas due to external heat emissions from bulb type lights, and the operator risks associated with traditional lighting methods, such as accidental burns and exposure to hazardous substances contained in the glass bulbs, are eliminated. In addition, LEDs are also safer for the environment as they are 100% recyclable, which eliminates the need for costly special disposal services required with traditional gas burning and arc type lamps. Durability/Mounting: The HAL-72-50W-LED hazardous area LED light is constructed of extruded aluminum with a tough powder coat finish for high strength and durability. The housing is IP54 rated, providing limited ingress protection against dusts, and basic protection against splashing water such as rain. This design is weather resistant, suitable for indoor or outdoor applications, and ideal for areas where wetness or dusty conditions are commonly encountered. The LEDs in this linear light are Cree X-Lamp XR-E units that have been chosen for their high lumen per watt ratio and extreme long life. These Cree LEDs provide over 90 lumens per watt output and have a 70% lumen retention at 50,000 hours, giving them better efficiency and operational life than comparable LEDs. Mounting for this unit is provided by two standard adjustable end brackets that allow operators to mount the light to flat surfaces and then adjust the light 170¡ vertically for the best placement. The entire assembly weighs 4.2 lbs and measures 71.76 inches in length, 2.68 inches wide and 1.69 inches deep, making it ideal for mounting in areas where space is limited and a low profile fixture is more readily installed. All mounting hardware is stainless steel. Wiring/Power: These hazardous location LED lights are equipped with 6 feet of cord containing a standard two wire (White+ Black-) connecting configuration. These lights operate from 12 or 24 volt DC current at 50.4 watts 4.16 amps on 12V DC and 2.08 amps on 24V DC. Versatility: The HAL-72-50W-LED is ETL approved for Class I Division 2 groups A, B, C and D locations. This unit carries an IP54 water resistant rating ensuring protection against limited ingress from dusts, dirt, and basic protection against light water spray landing directly on the fixture. This light is ideal for indoor or outdoor applications and industrial operations with hazardous location classification where dusty or wet conditions are commonly encountered. At Larson Electronics, we do more than meet your lighting needs. We also provide replacement, retrofit, and upgrade parts as well as industrial grade power accessories. Our craftsmen can custom build any lighting system and/or accessories to fit the unique demands of your operation. A commitment to honesty, quality, and dependability has made Larson Electronics a leader in the lighting and electronics business since 1973. Contact us today at 800-369-6671 or [email protected] for more information about our custom options tailored to meet your specific industry needs. Specifications / Additional Information HAL-72-50W-LED Hazardous Location LED Lighting Ratings/Approvals Lamp Type: LED United States & Canada Dimensions: Lamp 71.76"-L 2.68" -W 1.69"- D Class I Division 2 Groups A, B, C ? D Weight: 4.2 lb | 1.8 kg CSA 22.2 No. 250.0 Watts: 50 UL 1598 Voltage: 12-24V DC IP54 Ingress Protection Lumens: 3624 T3 Temperature Rating Lamp Life Expectancy: 100,000 Hours Stainless Steel Hardware CRI: 75 Amps: 4.16 A @ 12V DC | 2.08 A @ 24V DC Light Color: 6500K Special Orders- Requirements Beam Type: 100¡ Flood Contact us for special requirements Mounting: Standard Triangle End Brackets Toll Free: 888-325-4448 Temp Range: -40¡C - +85¡C Wiring: 6Ft Lead | White: + Black: - E-mail: [email protected] 3 year warranty replacement on this LED light. After 30 days, the customer ships the failed LED light and/or LED bulb to Larson Electronics at their expense. If the failure is a manufacturer defect, we will ship a new replacement to the customer. If failure occurs within 30 days of receipt, Larson Electronics will provide a return label via email to the customer. When the failed light is returned, Larson Electronics will ship a new replacement. Scroll Down to Purchase-

Reviews