Studies show that half of Industrial Ethernet problems are caused by cabling. The DSX CableAnalyzer validates cable performance to TIA 1005-A and ISO 11801:3 standards, allowing industrial companies and machine builders to ensure compliance, start up faster, and reduce production down time.

The DSX CableAnalyzer works on cables running EtherNet/IP, Profnet, ModBus TCP, EtherCAT, plus other protocols. It offers touchscreen project management, TIA Level IIIe accuracy, and advanced troubleshooting, all with integrated Wi-Fi and 8-hour battery life.

The kit includes the Versiv mainframe and remote units, a reference module, adapters, commonly used accessories, and a statement of calibration.Ê



Key features

  • Certifies copper cable for TIA category 5 through 6A
  • Shows Pass/Fail in 10 seconds, with full measurement details
  • Supports RJ45, M12D, and M12X connectors
  • Documents results with LinkWare PC


Cable types
Shielded and unshielded pair LAN cablingTIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 ½
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 ½ and 120 ½
Standard link interface adapters
Permanent link adaptersPlug type: shielded RJ45
Optional Plug type: Tera
Channel AdaptersJack type: shielded RJ45
Optional Jack type: Tera, GG45
Test standards
TIACategory 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IECClass C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequencyDSX-5000: 1000 MHz
General specifications
Speed of AutotestDSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL)
Input protectionProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display5.7 in LCD display with a projected capacitance touchscreen
CaseHigh impact plastic with shock absorbing overmold
DimensionsMain Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
WeightMain Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote:Lithium ion battery pack, 7.2 V
Typical battery life:8 hours
Charge time*Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supportedEnglish, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
CalibrationService center calibration period is 1 year
Integrated Wi-FiMeets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental specifications
Operating temperature32¡F to 113¡F (0¡C to 45¡C)
Storage temperature-14¡F to +140¡F (-10¡C to +60¡C)
Operating relative humidity0 % to 90 %, 32¡F to 95 ¡F (0¡C to 35¡C)
0 % to 70 %, 95¡F to 113 ¡F (35¡C to 45¡C)
VibrationRandom, 2 g, 5 Hz-500 Hz
Shock1 m drop test with and without module and adapter
SafetyCSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMCEN 61326-1
Performance specifications **
DSX-5000Category 6A/Class EA test modes (or lower link categories)Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modesExceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of twisted pair cabling1
ÊWithout remoteWith remote
Range800 m (2600 ft)150 m (490 ft)
Resolution0.1 m or 1 ft0.1 m or 1 ft
Accuracy± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)
Propagation delay
ÊWithout RemoteWith Remote
Range4000 ns750 ns
Resolution1 ns1 ns
Accuracy± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)
Delay skew
Range0 ns to 100 ns
Resolution1 ns
Accuracy± 10 ns
DC loop resistance test
Range0 ½ to 540 ½
Resolution0.1 ½
Accuracy± (1 ½ + 1 %)
Overload recovery timeLess than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

*Available in certain geographies currently

**Applies to accessories in the original product purchase