Fluke 1662 Multifunction Testers
Fluke 1662 Multifunction Installation Tester delivers solid, basic installation testing features
The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
- Measures RCD switching time and tripping level (ramp test)
- Measures trip time and current for RCD type A & AC in one test
- Measures RCD variable current
- Provides automatic RCD test sequence
- Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
- Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
- Includes a phase sequence indicator
- Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead
Key features
A solid, reliable, basic installation tester
- Tests voltage and frequency
- Checks wiring polarity to detect broken N wires
- Measures insulation resistance and loop and line resistance
- Measures motor windings with continuity test
- Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
AC voltage measurement | ||
Range | 500 V | |
Resolution | 0.1 V | |
Accuracy 45 Hz Ð 66 Hz | 0.8% + 3 | |
Input impedance | 360 k½ | |
Overload protection | 660 V rms | |
Continuity testing (RLO) | ||
Range (autoranging) | 20 ½ / 200 ½ / 2000 ½ | |
Resolution | 0.01 ½ / 0.1 ½ / 1 ½ | |
Open Circuit Voltage | >4 V | |
Insulation resistance measurement (RISO) | ||
Accuracy of test voltage (at rated test current) | +10%, -0% | |
Test voltage | 100 V 250 V 500 V 1000 V | |
Insulation resistance range | 20 M½ / 50 M½ 20 M½ / 100 M½ 20 M½ / 200 M½ 20 M½ / 200 M½ / 500 M½ 20 M½ / 200 M½ / 1000 M½ | |
Resolution | 0.01 M½ / 0.1 M½ 0.01 M½ / 0.1 M½ 0.01 M½ / 0.1 M½ 0.01 M½ / 0.1 M½ / 1 M½ 0.01 M½ / 0.1 M½ / 1 M½ | |
Test current | 1 mA @ 50 k½ 1 mA @ 100 k½ 1 mA @ 250 k½ 1 mA @ 500 k½ 1 mA @ 1 M½ | |
Loop and line impedance (ZI) | ||
Range | 10 ½ / 0.001 ½ / High current m½ mode | |
Resolution | 0.01 ½ / 0.1 ½ / 1 ½ | |
Prospective earth fault current, PSC test | ||
Range | 1000 A / 10 kA (50 kA) | |
Resolution | 1 A / 0.1 kA | |
Computation | Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. | |
RCD testing, RCD types tested | ||
RCD Type | A4, AC_, G_, S_ | |
Notes | _Responds to AC _General, no delay _Time delay 4Responds to pulsed signal 5Responds to smooth DC signal | |
Tripping speed test (_T) | ||
Current settings_ | 10-30-100-300-500-1000 mA Ð VAR 10-30-100 mA | |
Multiplier | x _, x 1 x 5 | |
Measurement range | RCD Type G | 310 ms 50 ms |
RCD Type S | 510 ms 160 ms | |
Notes | _1000 mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. | |
RCD/FI-Tripping Current Measurement/Ramp Test (I_N) | ||
Current range | 30% to 110% of RCD rated current_ | |
Step size | 10% of I_N_ | |
Dwell time | Type G | 300 ms/step |
Type S | 500 ms/step | |
Measurement accuracy | ±5% | |
Specified trip current ranges (EN 61008-1) | 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (²10 mA) 50% to 200% for Type B _5% for Type B | |
Notes | _30% to 150% for Type A I_N > 10 mA 30% to 210% for Type A I_N = 10 mA 20% to 210% for Type B | |
Phase Sequence Indication | ||
Icon | Phase Sequence indicator is active. | |
General Specifications | ||
Size (L x W x H) | 10 x 25 x 12.5 cm | |
Weight (incl. batteries) | 1.3 (kg) | |
Battery size, quantity | Type AA, 6 ea. | |
Sealing | IP-40 | |
Safety | Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034 | |
Overvoltage | CAT III / 500V; CAT IV 300V | |
Performance | EN61557-1 to EN61557-7 and EN61557-10 |