Three Stage "Smart" Chargers
Phase Three "Smart" battery charging technology is now available in a wide range of power levels, allowing you to select the right size, features and flexibility you require for virtually any application from small recreational craft to large live-aboards, workboats and other commercial vessels. These chargers interact with batteries to put them through the optimum three stage charge process which provides for fastest recovery and ideal conditioning, maximizing battery performance and extending battery life.
A selector switch adjusts output voltage to adapt for gel-cell/flooded lead-acid/AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries' ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.
Features
-
"Smart" circuitry provides three stage charging bulk, absorption, float.
-
Wide model range covers battery system ratings from 14-950 amp-hours
-
Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages.
-
Multiple isolated output banks; ammeter indicates total output current. (except PT-7)
-
Optional sensor adjusts output voltage based on battery temperature. (except PT-7)
-
Current limiting-prevents damage from overloading.
-
Charger status clearly displayed with L.E.D. and/or audible indicators or optional remote panel.
-
Use as a power supply; can power loads without a battery in line.
-
Built to last rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry.
-
Numerous Safety and EMC CompliancesTwo year parts and labor warranty
Models
12 Volt | 24 Volt | 32 Volt |
PT-7 | PT-24-8W | PT-32-25W |
PT-14W | PT-24-13W | |
PT-25W | PT-24-20U | |
PT-40U | PT-24-45U | |
PT-80 | PT-24-60W | |
PT-24-95U | ||
Detailed specifications below. |
Specifications
12 Volt Models | PT-7 | PT-14W | PT-25W | PT-40W | PT-80 |
Input VAC (50-60 Hz.) | 88-132 or | 85-264 | 90-132 or | 85-135 or | 90-264 |
Input Amps @ Full Load | |||||
@ 115 VAC | 2 | 2.8 | 6.5 | 8.5 | 12 |
@ 230 VAC | 1 | 1.4 | 4 | 4.3 | 7 |
P.F. Rating | >.65 | .93@230V | .7 | .7 | .95@230V |
Max Output Amps | 7 | 14 | 25 | 40 | 80 |
Output Banks | 2 | 3 | 3 | 3 | 3 |
Battery Capacity (Amp-Hours) | 14-70 | 28-140 | 50-250 | 80-400 | 160-800 |
Operating Temp. | T-1 | T-2 | T-4 | T-5 | T-7 |
Case Size Ref. | A-1 | A-2 | A-2 | A-3 | A-5 |
Weight; Lbs./Kg. | 3.2/1.5 | 8/4 | 8.2/4 | 12/6 | 15.2/7 |
Optional Temp.Sensor Model | N/A | TCS-12/24 | TCS-12/24 | TCS-12/24 | TCS-12/24 |
Remote Panel Model | N/A | RP | RP | RP | RP |
Equalize Option | No | Yes | Yes | Yes | Yes |
Output Indicator Ref. | M-1 | M-3 | M-3 | M-3 | M-3 |
Compliance Ref. | CG, CE | CG, CE | CG | CG, CE | CE |
24 Volt Models | PT-24-8W | PT-24-13W | PT-24-20U | PT-24-45U | PT-24-60W | PT-24-95U |
Input VAC (50-60 Hz.) | 85-264 | 90-132 or | 85-135 or | 90-264 | 207-253 | 90-264 |
Input Amps @ Full Load | ||||||
@ 115 VAC | 2.8 | 6.5 | 8.5 | 12 | NA | 26 |
@ 230 VAC | 1.4 | 4 | 4.3 | 7 | 13 | 14 |
P.F. Rating | .93@230V | .7 | .7 | .95@230V | .7 | .95@230V |
Max Output Amps | 8 | 13 | 20 | 45 | 60 | 95 |
Output Banks | 3 | 3 | 3 | 3 | 3 | 3 |
Battery Capacity (Amp-Hours) | 16-80 | 26-130 | 40-200 | 90-450 | 120-600 | 180-950 |
Operating Temp. | T-2 | T-3 | T-5 | T-8 | T-6 | T-8 |
Case Size Ref. | A-2 | A-2 | A-3 | A-5 | A-6 | A-6 |
Weight; Lbs./Kg. | 8/4 | 8.2/4 | 12/6 | 12.2/6 | 24.1/11 | 24.5/11 |
Optional Temp.Sensor Model | TCS-12/24 | TCS-12/24 | TCS-12/24 | TCS-12/24 | TP | TCS-12/24 |
Remote Panel Model | RP | RP | RP | RP | N/A | RP |
Equalize Option | Yes | Yes | Yes | Yes | No | Yes |
Output Indicator Ref. | M-3 | M-3 | M-3 | M-3 | M-2 | M-3 |
Compliance Ref. | CG, CE | CG | CG, CE | EN, CE | EN, CE | EN, CE |
32 Volt Model | PT-32-25W |
Input VAC (50-60 Hz.) | 104-126 |
Input Amps @ Full Load | |
@ 115 VAC | 15 |
@ 230 VAC | N/A |
P.F. Rating | .7 |
Max Output Amps | 25 |
Output Banks | 3 |
Battery Capacity (Amp-Hours) | 50-250 |
Operating Temp. | T-6 |
Case Size Ref. | A-4 |
Weight; Lbs./Kg. | 12.2/6 |
Optional Temp.Sensor Model | TP |
Remote Panel Model | N/A |
Equalize Option | No |
Output Indicator Ref. | M-2 |
Compliance Ref. | EN, CE |
Case Size
Inches | Centimeters | |||||
Ref | H | W | D | H | W | D |
A-1 | 10.5 | 5.0 | 2.8 | 26.7 | 12.7 | 7.1 |
A-2 | 12.5 | 7.7 | 4.3 | 31.8 | 19.6 | 10.9 |
A-3 | 13.85* | 9.5 | 4.8* | 35.2* | 24.1 | 12.2* |
A-4 | 13.8A | 9.8 | 5A | 35A | 24.9 | 12.7A |
A-5 | 14.8B | 9.6 | 5.6B | 37.6B | 24.4 | 14.2B |
A-6 | 17.5C | 12 | 7.2C | 44.5C | 30.5 | 18.3C |
* Add .75" (1.9 cm) to height and 1.35" (3.4 cm) to depth |
Temperature Rating References:
T-1 | -10°C to +45°C; Derate linearly from 100% @ 0°C to 80% @ -10°C |
T-2 | -10°C to +60°C; Derate linearly from 100% @ 40°C to 60% @ 60°C |
T-3 | -10°C to +60°C; Derate linearly from 100% @ 50°C to 60% @ 60°C |
T-4 | -10°C to +60°C; Derate linearly from 100% @ 40°C to 60% @ 60°C |
T-5 | -40°C to +60°C; Derate linearly from 100% @ 50°C to 75% @ 60°C |
T-6 | -20°C to +50°C; Full output |
T-7 | -20°C to +70°C; Derate linearly from 100% @ 45°C to 50% @ 70°C |
T-8 | -20°C to +70°C; Derate linearly from 100% @ 50°C to 50% @ 70°C |
Output Indicator References
M-1 | Total output ammeter |
M-2 | Charge/Float L.E.D. |
M-3 | Total output ammeter and charger status L.E.D.'s/Alarms |
Compliance References*
See matrix for applicable models
CG USCG CFR 183.410 (Ignition protected)
EN EN 60335-1, EN 60335-2-29
CE Carries the CE Mark
* Numerous other Safety and EMC compliances may also apply. Contact factory if further compliance
information is required.
Nominal Output Voltages at Gel/Flooded Switch Settings
(Without Temperature Compensation option installed or at 22.2˚C (72˚F) with Temperature
Compensation option installed.)
| 12 Volt Models | 24 Volt Models | 32 Volt Model | |||
Charge | Float | Charge | Float | Charge | Float | |
Setting | @ 50% load | @ .5 amp load | @ 50% load | @ .5 amp load | @ 50% load | @ .5 amp load |
Gel-Cell | 14.0 VDC | 13.6 VDC | 28.0 VDC | 27.2 VDC | 37.3 VDC | 36.2 VDC |
Flooded/AGM | 14.2 VDC | 13.4 VDC | 28.4 VDC | 26.8 VDC | 37.8 VDC | 35.7 VDC |