Larson Electronics *RENTAL* 25KVA Temporary Power Distribution Panel - 480V to 120/240V 1PH - (2) L6-30R (6) 5-20R GFCI

Larson Electronics

(No reviews yet) Write a Review
SKU:
RNT-MGL25-8C-480-120V-GFI-100
Weight:
0.00 LBS
Call for price
This unit is for rentals. The Larson Electronics RNT-MGL25-8C-480-120V-GFI-100 Temporary Power Distribution System converts 480VAC electrical current into single-phase 120/240VAC. This unit provides operators the ability to safely tap into and distribute 480V power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and UseThe RNT-MGL25-8C-480-120V-GFI-100 temporary power distribution system gives operators the ability to power their 240 volt and 120 volt equipment from a single system. On the primary side, operators connect 480 volt line-in power using 100` of #8 Type W cord with an ACP-6034BC pin/sleeve cord cap. On the secondary side, operators are provided access to two, L6-30R receptacles for 240V equipment and six, 5-20R GFCI duplex receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 100` #8 Type W line-in cord with a 60-amp 600V-rated ACP-6034BC pin/sleeve cord cap brings 480V power into the NEMA 3R 60-amp 480V three phase primary disconnect, which contains two 60-amp time delay fuses, and passes 480V single-phase power to the transformer. The NEMA 3R 25 KVA transformer converts 480V to 120/240V single phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 120/240V 125-amp MLO single phase circuit breaker panel. This secondary panel contains two, 30-amp 250V 2-pole breakers protecting two, 30-amp 250V L6-30R receptacles and six, 20-amp 125V 1-pole breakers protecting six, 20-amp 125V GFCI duplex receptacles. Click Photo to Enlarge Click Photo to Enlarge Click Photo to Enlarge Protective Construction: The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style frame, resulting in an extremely stable, durable, and mobile power distribution platform. Two run-flat rubber tires and a dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA, and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics` Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information RNT-MGL25-8C-480-120V-GFI-100 Temporary Power Distribution Ratings Line In: 100` #8 Type W Cord Max Primary OCP: 60A @ 480V Cord Cap: 60A ACP-6034BC Pin/Sleeve [600V-rated] Max Secondary Output: 104.2A @ 240V Primary Voltage: 480V UL 1640 Portable Power-Distribution Equipment Primary Disconnect: 480V 60A 3PH N3R Fused @ 60A NEMA 3R Indoor or Outdoor Use Primary Protection: 60A Time Delay Fuses Made in the USA Transformer: 25 KVA 480V to 120/240V 1PH N3R Secondary Voltage: 120/240VAC 1PH Secondary Panel: 120/240V 125A MLO 1PH Panel N3R Secondary Breakers: (2) 2P [250V], (6) 1P [125V] Secondary Receptacles: (2) 30A L6-30R [250V], (6) 20A 5-20R GFCI Duplex [125V] Secondary Protection: Weatherproof Covers, GFCI Special Orders- Requirements Form Factor: Powder Coated Steel Dolly Cart w/ Run Flat Tires Contact us for special requirements Dimensions: W-40" X D-40" X H-48" Toll Free: 888-325-4448 Weight: 650 lbs Intl: 1-214-616-6180 *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* E-mail: [email protected] Scroll Down to Purchase

Reviews