Larson Electronics Hazardous Location 15 KVA C1D2 Power Distribution - 480V to 120V - (8) 20A 120V GFCI

Larson Electronics

(No reviews yet) Write a Review
SKU:
EPMGL-480-15KVA-120-8X120.20A
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics EPMGL-480-15KVA-120-8X120.20A hazardous location temporary power distribution system converts 480V AC 3-phase current to single phase 120V AC 60 Hz. This HAZLOC power distribution system provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources within classified environments. This portable substation is suitable for Class I, Division 2 applications, with a fully encapsulated C1D2 transformer and load center. This power distribution system is configured to transform 480V to 120V. Operators can connect up to eight 120V devices on 120V circuits via eight 5-20R GFCI protected receptactles with waterproof covers. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The EPMGL-480-15KVA-120-8X120.20A hazardous location temporary power distribution system provides a safe and reliable way for operators in classified locations to safely tap into and utilize power sources independently of the work area. This unit provides an effective HAZLOC power distribution system for operators performing plant turnarounds, maintenance, equipment installations and any activities requiring an alternative to native power sources. This portable transformer is designed to operate with 480V, three phase, 60 Hz which it then steps down to 120V AC 60 Hz. The power distribution system on this portable substation makes 120V AC available via eight explosion proof 5-20R 20-amp, 125V GFCI protected receptacles. Description: The EPMGL-480-15KVA-120-8X120.20A portable power distribution substation converts three phase, 480V AC electrical current to single phase 240V and 120V AC via an encapsulated Class I, Division 2 15KVA transformer (480V-3P to 120/240V-1P 60Hz). 20` of 10/4 SOOW line-in cable is included to connect the substation to a primary 480V primary power supply. A Class I, Division 2 30-amp disconnect switch provides primary line-in protection and supplies primary power to the 15 KVA transformer. Secondary current is wired to a 120/240V, 40-amp GFCI breaker for circuit protection. Connection for 120V AC is through eight 5-15R/5-20R 20-amp, 125V, explosion proof receptacles with spring loaded covers. The transformer is potted and the entire system is built and certified to UL 1640 and UL 1203 standards. The transformer and load center/distribution assembly is mounted to a powder coated aluminum, dolly cart style, frame resulting in an extremely stable, durable, and mobile power distribution platform. Two run-flat rubber tires and a dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA, and can be equipped with skids or trailer mounted. Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information EPMGL-480-15KVA-120-8X120.20A -Temporary Power Distribution System Ratings/Approvals Line In: 20’ 10/3 SOOW Max Primary OCP: 30 amps @ 480V Primary Voltage: 480V AC 60 Hz 3P Max Secondary OCP: 40 amps @ 208Y Disconnect: 30A 480V, 3PH NEMA 3R Transformer: 15KVA 480-120/240V Encapsulated UL 1640 Secondary Voltage: 120V AC 60 Hz Made in the USA Secondary Protection: 40A GFCI Secondary Outlets: (8) 20A, 125V, 5-15R/5-20R Receptacles Special Orders- Requirements Form Factor: Powder Coated Aluminum Dolly Cart w/ Run Flat Tires Contact us for special requirements Dimensions: W-40" X D-40" X H-48" Toll Free: 888-325-4448 Weight: 600 lbs E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram.*All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews