Made in the USAThe Larson Electronics HALP-EMG-24-2L Hazardous Area Fluorescent Light Fixture is U.S./Canada UL Listed Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperature rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime.The HALP-EMG-24-2L hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-24-2L also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications.This fluorescent light works, mounts and is wired like our HALP-24-2L explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. NOTE ON LAMPS: This fixture comes equipped with F17-T8 lamps producing 1,325 lumens per bulb, a 4100 Kelvin color and a 20,000 hour rated service life. Surface Mounting: Flange type aluminum mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 14.91" inches on center apart along the top of this hazardous location light. The mounting holes are 9.5" inches on center across the top of the light.Pendant Mounting:This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4" NPT hubs on either side of the fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture.Suggested Applications: HALP-EMG-24-2L is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.Made in USA QualityLamp Options1. Each unit dialectically tested.2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface.3. Fixture housing constructed of glass fiber reinforced polyester.4. Relamping done via 6 stainless steel snap locking latches, which enable the operator to remove the door and access the lamps.5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection.6. 1/2" or 3/4", threaded access hole for wiring conduit.F17-T8 1325 lumens per bulb (2560) lumens total), 24,000 hours life, 4100 Kelvin color Specifications / Additional Information HALP-EMG-24-2LU.L. RatingsUL Listing: United States - CanadaClass I Division 2, Groups A, B, C and D Lamp Type: Fluorescent Class II, Division 2, Groups F, G Dimensions: W-8.25 " L-52" H-7"UL 1598A Marine TypeWeight: 8 Lbs UL 844Voltage: Universal 120-277VAC 50/60 hzUL 924Total Watts: 34 watts UL 8750Total Lumens F17-T8 Bulbs: 2,650IP66 RatedLuminous Efficacy F17-T8 Bulbs: 92 Lm/WNEMA 4XLED Lamp Life Expectancy: 100,000+ HoursCSA 22.2 No. 137-M81Color Temp: 4100KcUL Listed for CanadaBeam Angle: 150¡Meets USCG SpecsAmbient Operating Temp Range:-40¡C to +65¡CT4 Temperature RatingOperating Temp Range: T4C ratedSwitch Leg for Powering Light On/OffMounting: Surface Standard - Pendant OptionalSpecial Orders- RequirementsWiring Hub: (2) 1/2" or 3/4`" threaded NPT hubsContact us for special requirements Battery Backup: 90 minute runtime at 900 lumensToll Free: 1-800-369-6671 U.L Approval: U.S Certificate Canada CertificateE-mail:[email protected]
Larson Electronics Class I, Div. II Fluorescent Fixture w/ Emergency Ballast - 2 Foot, 2 Bulb
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics Class I, Div. II Fluorescent Fixture w/ Emergency Ballast - 2 Foot, 2 Bulb
- SKU:
- HALP-EMG-24-2L
- UPC:
- Weight:
- 0.00 LBS
!