Image coming soon

Larson Electronics 72 Watt Class 1 Division 2 Emergency LED Light for Corrosion Resistant Requirements (Saltwater)

Larson Electronics

(No reviews yet) Write a Review
SKU:
HALP-EMG-48-3L-LED
Weight:
0.00 LBS
Call for price
Made in the USAThe HALP-EMG-48-3L-LED Hazardous Area LED Light Fixture from Larson Electronics is U.S./Canada UL Listed Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperature rating, and is specifically designed to handle the rigors of wet and corrosive marine environments.The HALP-EMG-48-3L-LED hazardous area LED light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing, and an impact resistant acrylic diffuser. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion.This fixture is UL 844 rated and Class 1 Division 2, Groups A, B, C, D approved. The HALP-EMG-48-3L-LED also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. We have eliminated the ballast box normally associated with fluorescent fixtures which reduces overall weight and creates a slimmer unit profile. There is no ballast in this unit and the included LEDT-24W LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard T8 bulbs.NOTE ON LAMPS: All hazardous location lights are shipped with bulbs. Three 24 watt LED tube bulbs with color temperature of 5600K and a 50,000 hour life span come equipped with this fixture.Standard Flange Brackets: Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 36 9/16 inches on center apart along the top of this hazardous location light. The mounting holes are 7 inches on center across the top of the light. Pendant Mounting: This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with eihter two 1/2" or 3/4" NPT hubs on either side of the fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture.Suggested Applications: The HALP-EMG-48-3L-LED is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks. Made in USA QualitySuperior LED Benefits1. Each unit dialectrically tested.2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. 3. Fixture housing constructed of glass fiber reinforced polyester. 4. No ballast box. No ballast to replace. We simply run the black wire to one end of the bulb and white wire to the other. 5. Relamping done via 6 stainless steel snap locking latches which enables the operator to remove the door and access the lamps. 6. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection. . 7. 1/2" or 3/4", threaded access hole for wiring conduit. 1. 50,000 hour lifespan.2. Can SAVE 50% or more on energy.3. Qualifies retrofit projects for financial incentives, including utility rebates, tax credits and energy loan programs.4. Reduces energy use and prolongs life-spans of peripheral cooling units (A/C, refrigeration)5. 100% recyclable.6. No toxins-lead, mercury.7. No UV light, infrared radiation or CO2 emissions.8. Qualifies buildings for LEED and other sustainable business certifications.9. Bright, even light maintains consistent color over time.10. Instant on/off – No flickering, delays or buzzing. 11. Very good color rendering.12. Vibration/impact resistant.13. Significantly cooler operation.14. Less frequent outages, higher output improves workplace safety.Specifications / Additional Information HALP-EMG-24-3L-LED Hazardous AreaU.L. RatingsUL Listing: United States - CanadaClass I Division 2, Groups A, B, C, DLamp Type: LED Class II, Division 2, Groups F, G Dimensions: W-8.25 " L-52 " H-7"UL 844 Weight: 8 Lbs UL 924 - Failsafe battery backup Voltage:120-277VACUL 1598A Marine Type (Salt water)Low Voltage Optional: 9-32VDCMeets USCG SpecsTotal Watts: 72 wattsT4A Temperature RatedTotal Lumens: 6,480cUL Listed for Canada Luminous Efficacy: 90 Lm/WLamp Life Expectancy: 50,000 HoursColor Temp: 5600K- CRI-75Beam Angle: 150 degrees Efficiency: 98 Lumens per WattAmbient Operating Temp Range: -30¡ C to +85¡ COperating Temp Range: T4A RatedBattery Backup: 90 Minute Runtime Surface Mounting: (2) Flange Type Aluminum BracketsPendant Mounting: (2) 3/4" Threaded NPT Hubs on Either Side Special Orders- RequirementsWiring Hub:1/2" or 3/4" Threaded HubsContact us for special requirements Toll Free: 888-325-4448U.L Approval: U.S Certificate Canada CertificateIntl: 1-903-270-1187Meets US Coast Guard specifications.E-mail: [email protected]

Reviews