Larson Electronics 7.5KVA Portable Power Distribution - 480V to 120/240V 1PH - (4) 5-20R GFCI Receptacles - 25' Cord

Larson Electronics

(No reviews yet) Write a Review
SKU:
MGL-7.5-480-100AMB-4X120
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics MGL-7.5-480-100AMB-4X120 power distribution substation converts 480VAC electrical current into single phase 120/240VAC. This unit provides operators the ability to safely tap into and distribute 480VAC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The MGL-7.5-480-100AMB-4X120 portable power distribution system gives operators the ability to power their single phase 120 volt equipment from a single system. On the primary side, operators connect three phase 480 volt line-in power using a 25` #10 SOOW cord with a NPJ6484 cord cap. On the secondary side, the panel contains four 5-20R GFCI receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 25` #10 SOOW cord with a 60-amp 600V rated NPJ6484 cord cap brings 480V three phase power to the NEMA 3R 30-amp 480V three phase primary disconnect, which contains two 20-amp time delay fuses, and passes 480V single phase through to the transformer. The NEMA 3R 7.5KVA transformer converts 480V single phase power to 120/240V single phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 100-amp 120/240V single phase main circuit breaker panel. This secondary main circuit breaker panel contains four 20-amp 1-pole 125V breakers protecting four 20-amp 125V 5-20R GFCI receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style frame, resulting in an extremely stable, durable, and mobile power distribution platform. A dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks. This can be replaced for an additional cost with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs. Larger units are available upon request and can be equipped with skids or trailer mounted. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGL-7.5-480-100AMB-4X120 Power Transformer Ratings Line-In: 25` #10 SOOW Cord Max OCP Primary: 20A @ 480V Line-In Cord Cap: 60A NPJ6484 [600V Rated] Max Secondary OCP: 100A @ 240V Primary Voltage: 480VAC, 3PH Max Secondary Output: 31.3A @ 240V Primary Disconnect: 30A 480V 3PH Fused @ 20A N3R UL 1640 Portable Power-Distribution Equipment Primary Panel: - NEMA 3R Indoor / Outdoor Use Primary Breakers: - Made in the USA Primary Receptacles: - Primary Protection: Disconnect Switch, Time Delay Fuses Transformer: 7.5KVA 480V to 120/240V 1PH 60Hz N3R Secondary Voltage: 120/240VAC, 1PH Secondary Disconnect: - Secondary Panel: 100A 120/240V 1PH MCB N3R Secondary Breakers: (4) 20A 1P [125V] Secondary Receptacles: (4) 5-20R GFCI [125V] Special Orders- Requirements Secondary Protection: GFCI, Circuit Breakers, Weatherproof Covers Contact us for special requirements Form Factor: Square tube frame, skid pockets, top pick eye, no flat tires Phone: 1-214-616-6180 Frame Materials: Powder coated steel frame Toll Free: 888-325-4448 Dimensions: W-40" X D-40" X H-48" Fax: 1-903-498-3364 Weight: 600 pounds E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews