Made in Texas The Larson Electronics MGS-4803P.400A-CL-4XPS-45KVA-208.1203P.150A-11XMG Power Distribution Substation converts 480V AC three phase electrical current to three phase 208Y/120V AC. This galvanized unit provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use The MGS-4803P.400A-CL-4XPS-45KVA-208.1203P.150A-11XMG portable power distribution system gives operators the ability to power their 480 volt, 240 volt and 120 volt equipment from a single system. On the primary side, operators connect 480 volt line-in power via two sets of 400-amp 600V rated camlocks (brown, orange, yellow, green) and to one 100-amp 4100R7W pin/sleeve, one 60-amp 460R7W pin/sleeve and two 30-amp 430R7W pin/sleeve receptacles for 480V equipment. All receptacles on the primary side are protected by weatherproof covers. On the secondary side, operators connect to six HBL63CM69 receptacles for 240V equipment and to five HBL53CM62 receptacles for 120V equipment. All receptacles on the secondary are equipped with in-use waterproof covers and all breakers on the secondary side feature GFCI protection. Operation: Two sets of 400-amp 600V rated camlocks (brown, orange, yellow, green) bring 480V three phase power to the NEMA 3R 400-amp 480V three phase I-line panel on the primary side, which contains two 200-amp interlock main breakers that are individually connected to a set of camlocks for backfeed to utilize as an autotransfer switch. The primary panel contains one 100-amp 3-pole 480V breaker protecting one 100-amp 4100R7W pin/sleeve receptacle, one 60-amp 3-pole 480V breaker protecting one 60-amp 460R7W pin/sleeve receptacle two 30-amp 3-pole 480V breakers protecting two 30-amp 430R7W pin/sleeve receptacles, as well as one 70-amp 3-pole 480V breaker protecting the transformer. The NEMA 3R 45 KVA transformer converts three phase 480V AC to three phase 208Y/120V AC 60Hz and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 150-amp three phase 208Y/120V AC main circuit breaker panel. This secondary panel contains six 50-amp 2-pole 250V GFCI breakers protecting six 50-amp 125/250V HBL63CM69 receptacles and five 20-amp 1-pole 125V GFCI breakers protecting five 20-amp 125V HBL53CM62 receptacles. Cam Locks Cam Locks Disconnect Cam Lock Fuse Click Images to Enlarge Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this galvanized unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. This model is equipped with forklift skid pockets, locking casters, and a top located lifting eyelet which allows easy lifting with cable or chain hooks. This can be replaced for an additional cost with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs. Larger units are available upon request and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGS-4803P.400A-CL-4XPS-45KVA-208.1203P.150A-11XMG Power Transformer Ratings Line-In: (2 Sets) 400A Camlocks [600V Rated - Brown, Orange, Yellow, Green] Max OCP Primary: 400A @ 480V Line-In Cord Cap: - Max OCP Secondary: 150A @ 208V Primary Voltage: 480V 3PH NEMA 3R Indoor or Outdoor Use Primary Disconnect: - Made in the USA Primary Panel: (1) 400A 480V 3PH I-line Panel N3R w/ (2) 200A 480V 3PH Interlock MBs UL 1640 Portable Power-Distribution Equipment Primary Breakers: (1) 100A 3P [480V], (1) 70A 3P [480V], (1) 60A 3P [480V], (2) 30A 3P [480V] Primary Receptacles: (1) 100A 4100R7W Pin/sleeve [480V], (1) 60A 460R7W Pin/sleeve [480V], (2) 30A 430R7W Pin/sleeve [480V] Primary Protection: Circuit Breaker, Weatherproof Covers Transformer: 45KVA 480V to 208Y/120V 3PH 60Hz N3R Secondary Voltage: 208Y/120V AC 3PH Secondary Panel: 150A 208Y/120V 3PH MCB N3R Secondary Breakers: (6) 50A 2P GFCI [250V], (5) 20A 1P GFCI [125V] Secondary Receptacles: (6) 50A HBL63CM69 [125/250V], (5) 20A HBL53CM62 [125V] Special Orders- Requirements Secondary Protection: GFCI Breakers, In-use Waterproof Receptacle Covers Contact us for special requirements Form Factor: Square tube frame w/ 1/8" tubing, skid pockets, top pick eye & 8” locking casters Toll Free: 888-325-4448 Frame Materials: Galvanized steel frame Intl: 1-214-616-6180 Dimensions: 48” X 48” X 80” Fax: 1-903-498-3364 Weight: 850 pounds E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews