Larson Electronics 36W Flameproof Fluorescent Emergency Linear Fixture - 220V, 50Hz - (2) 2' T8 Lamps - ATEX/IECEx

Larson Electronics

(No reviews yet) Write a Review
SKU:
ATEX-HALP-EMG-24-2L-T8-2X18W-R1-220V
Weight:
0.00 LBS
Call for price
The Larson Electronics ATEX-HALP-EMG-24-2L-T8-2X18W-R1-220V Flameproof Fluorescent Emergency Linear Fixture is designed for outdoor illumination in ATEX/IECEx rated flammable environments. Equipped with two, 2-foot T8 fluorescent lamps, this emergency 36-watt fixture is compatible with 220V AC, 50 Hz. The IP66-rated unit is constructed of glass fiber reinforced polyester with a polycarbonate lens and features an internal electronic ballast/inverter with an interlocking system for protection. The ATEX-HALP-EMG-24-2L-T8-2X18W-R1-220V is a powerful lighting solution for combustible facilities, industrial sites and outdoor locations. This 36-watt unit operates on 220V AC, 50 Hz and contains two, 2-foot T8 fluorescent lamps (2-pin G13 base). During use, the emergency fixture offers 2,380 lumens of output in a flood beam configuration, with an exceptional CRI rating of 75. Color temperature options include: 5000K, 4100K or 2700K. An electronic, internal ballast ensures reliable lighting performance and features two interlock switches that disconnects all poles to the ballast and inverter, as well as turns the power off when the diffuser is opened. This full-plastic explosion proof fixture is constructed of glass fiber reinforced polyester. The lens consists of UV-resistant polycarbonate and is equipped with a foam gasket. This IP66-rated unit comes with an approximate lifespan of 7,500+ hours and is suitable for ATEX/IECEx rated Zone 1/Zone 2 and Zone 21/Zone 22 flammable environments. Equipped with a T4 temperature rating, the outdoor fixture can be used in locations with ambient temperatures ranging between -25¡C to +40¡C. Battery-powered Emergency Backup: The flameproof light contains a battery backup unit that adds emergency light functionality to the fixture. With an electronic inverter, this fixture will continue to operate one fluorescent lamp for 90 minutes at 1,190 lumens after the main electrical power to the light is severed. Once standard electrical power is restored, the emergency battery pack will be recharged, which takes approximately 24 hours from a drained state. The fixture contains three LED status lights for real-time monitoring in emergency mode: red, yellow and green. Wiring: The ATEX-HALP-EMG-24-2L-T8-2X18W-R1-220V features L1, L2, L, N and two PE terminals for completing electrical connections. Cables are fed through one, 1.5" (M25) hub, located at the side of the fixture. This unit comes with two, 1.5" (M25) molded plastic/polyamide stopping plugs. A central locking system protects the internal components of the unit, which must be unlocked during installation or relamping. Mounting Compatibility: This explosion proof light is compatible with the following mounting configurations (not included): ceiling, pendant, chain hanging, angle bracket, pole clamp oil derrick and pole top. We offer these mounting accessories at an additional cost. Suggested Applications: Paint spray booths, aircraft maintenance, oil drilling rigs, refineries, solvent and cleaning areas, gas processing plants, chemical manufacturing, waste water treatment plants, offshore applications and more. At Larson Electronics, we do more than meet your lighting needs. We also provide replacement, retrofit, and upgrade parts as well as industrial grade power accessories. Our craftsmen can custom build any lighting system and/or accessories to fit the unique demands of your operation. A commitment to honesty, quality, and dependability has made Larson Electronics a leader in the lighting and electronics business since 1973. Contact us today at 800-369-6671 or [email protected] for more information about our custom options tailored to meet your specific industry needs. Specifications / Additional Information ATEX-HALP-EMG-24-2L-T8-2X18W-R1-220V Flameproof Emergency Fluorescent Light Ratings/Approvals Listing: International, European Union ATEX/IECEx Rated Lamp Technology: Fluorescent Zone 1/Zone 2 Dimensions: 28.5" x 8.7" x 5.7" (725mm x 222mm x 145mm) Zone 21/Zone 22 Lamp Quantity: 2 Ex deqmb IIC T4 Gb Weight: 14.99 lbs (6.8 kgs) Ex II 2GD Voltage: 220V AC IP66 Frequency: 50 Hz Emergency Backup Mode Total Watts: 36W (2 x 18W) Total Lumens: 2,380 lms (2 x 1,190 lms) Luminous Efficacy: - Lamp Life: 7,500+ Hours Color Temperature: 5000K, 4100K or 2700K Color Rendering Index: 75 Lamp Type: T8 Lamp Base: 2-pin G13 Replacement Lamp: - Beam Angle: - Lighting Configuration: Flood Pattern Power Efficiency: - Power Factor: >0.98 Ballast Type: Electronic Ballast Position: Internal Inverter Type (Emergency Mode): Electronic Emergency Runtime: 90 Minutes Emergency Start Time: 0.1 Second Emergency Lumens: 1,190 lms (1 Lamp) Battery Recharge Time: 24 Hrs Emergency Status Display: (3) LEDs (Red, Yellow, Green) Amperage: 0.2A @ 220V Ambient Operating Temp Range: -25¡C to +40¡C Operating Temp Rating: T4 Housing Material: Glass Fiber Reinforced Polyester Housing Finish: - Lens Material: Polycarbonate Gasket Material: Foam Special Orders- Requirements Mount: - Contact us for special requirements Terminals: L1, L2, L, N + (2) PE - 0.39" (10mm) Toll Free: 888-325-4448 Hub Quantity: 1 Intl: +01-903-498-3364 Hub Size/Location: (1) 1.5" (M25) @ Side Fax: 1-903-498-3364 Stopping Plugs: (2) 1.5" (M25) Molded Plastic/Polyamide E-mail: [email protected]

Reviews