Made in Texas The Larson Electronics MGL-25-480.3P-1X480.50A-4X120.20A-2X240.50A temporary power distribution system converts 480 VAC current to single phase 120V AC and 240V AC 60 Hz. This power distribution system provides operators the ability to safely tap into and distribute 480VAC power from a variety of sources including generators and direct grid power. This portable substation is suitable for outdoor applications with a fully potted transformer and NEMA 3R load center. This power distribution system is configured to transform 480V to 240/120V Delta. Operators can connect up to four 20A devices on 120V circuits via 5-20R GFCI duplex receptacles, two 50A 240V devices via the CS8269 receptacles with covers, and one 50A 480V device via the CS8169 receptacle with cover. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* The MGL-25-480.3P-1X480.50A-4X120.20A-2X240.50A temporary power distribution system provides a safe and reliable way for operators in industrial settings to tap into and utilize power sources independently of the work area. This unit provides an effective power distribution system for operators performing plant turnarounds, maintenance, equipment installations and any activities requiring an alternative to native power sources. This portable transformer is designed to operate with 480V, three phase, 60hz which it then steps down to 1ph 120V AC and 1ph 240V AC. The power distribution system on this portable substation makes 120V AC available via (4) 5-20R 20amp, 125V GFCI protected duplex receptacles, 240V AC available via (2) CS8269 50amp, 250V receptacles, and 480V AC via (1) CS8169 50amp receptacle. Description: The MGL-25-480.3P-1X480.50A-4X120.20A-2X240.50A portable power distribution substation converts three phase, 480V AC electrical current to single phase 120V AC and 240V AC via a 25KVA transformer (480V to 120/240V, 1PH, 60Hz). 10 feet of #2 3/4 SOOW line in cable is included to connect the substation to a primary 480V primary power supply. A 125A main breaker panel take 480V primary voltage and provides a single 50amp CS8169 receptacle with waterproof cover protected by a 50A breaker and feeds the 480/120-240V transformer protected by a 60A breaker. Secondary current is wired to a 120/240V, single phase, 100-amp load center with main breaker for circuit protection. 120/240V line out protection is provided by four 20-amp, 125V, single pole breakers and two 50-amp, 250V, 2 pole breakers. Connection for 240/120V AC is through receptacles mounted on the side of the load center. Receptacles include eight 20-amp, 125V, GFCI waterproof duplex receptacles and two 50-amp, 250V receptacles. The load center is rated NEMA 3R, the transformer is potted and the entire system is built and certified to UL 1640 standards. The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style frame resulting in an extremely stable, durable, and mobile power distribution platform. Two run-flat rubber tires and a dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA and can be equipped with skids or trailer mounted. Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGL-25-480.3P-1X480.50A-4X120.20A-2X240.50A -Temporary Power Distribution System Ratings Line In: 10` #2 3/4 SOOW UL 1640 Portable Power-Distribution Equipment Primary Voltage: 480V AC 60 Hz NEMA 3R Indoor or Outdoor Use Primary Panel: 125A MCB N3R Pane Made in the USA Primary Protection: (1) 50A 480V & (1) 60A 480V Breakers Primary Outlets: (1) 50A 480V CS8169 Receptacles Transformer: 25KVA 480-120/240 Delta N3R Secondary Voltage: 240/120V AC 60 HZ Secondary Panel: 100A MCB N3R Pane Secondary Protection: (4) 20A 120V & (2) 50A 240V Breakers Secondary 120V Outlets: (8) 20A, 125V, Weatherproof 5-20R GFCI Protected Receptacles Secondary 240V Outlets: (2) 50A, 250V, CS8269 Receptacles Form Factor: Powder Coated Steel Dolly Cart w/ Run Flat Tires Dimensions: W-40" X D-40" X H-48" Special Orders- Requirements Weight: 600 lbs Contact us for special requirements Features: Toll Free: 888-325-4448 Max Primary OCP: 125 amps @ 480V Max Secondary OCP: 100 amps @ 240V E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase
Larson Electronics 25 KVA Temporary Power Distribution - 480V to 240/120V - (1) 50A 480V, (8) 20A 120V, (2) 50A 240V
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics 25 KVA Temporary Power Distribution - 480V to 240/120V - (1) 50A 480V, (8) 20A 120V, (2) 50A 240V
- SKU:
- MGL-25-480.3P-1X480.50A-4X120.20A-2X240.50A
- UPC:
- Weight:
- 0.00 LBS
!