Made in Texas The Larson Electronics MGL-480D-30AFT-15KVA-2X208.30A-12X120.20A-20C temporary power distribution system converts three phase 480V AC electrical current into 208Y/120V three phase. This unit provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use: The MGL-480D-30AFT-15KVA-2X208.30A-12X120.20A-20C portable power distribution system gives operators the ability to power their 480 volt, 240 volt and 120 volt equipment from a single system. On the primary side, operators connect three phase 480V using 20` of #6 SOOW cord to one L16-30R receptacle for 480V equipment. On the secondary side, operators connect to two L15-30R receptacles for 240V equipment and to twelve 5-20R GFCI receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 20` #6 SOOW cord brings three-phase 480V power to the first NEMA 3R 30-amp, 480V three phase primary disconnect, which contains three 30-amp time delay fuses protecting one 30-amp, 480V L16-30R receptacle, and passes 480V three phase power to the second disconnect on the primary side. The NEMA 3R 30-amp, 480V three phase second primary disconnect contains three 25-amp time delay fuses and passes 480V three phase to the transformer. The NEMA 3R 15 KVA transformer converts 480V to 208Y/120V three phase and passes the current to the secondary side. The secondary side of the transformer feeds a NEMA 3R 50-amp 208Y/120V three phase main lug only panel. This secondary side contains two 30-amp, 3-pole, 250V breakers protecting two 30-amp, 250V L15-30R receptacles, and twelve 20-amp, 1-pole, 125V breakers protecting twelve 20-amp, 125V 5-20R GFCI receptacles. Protective Construction: The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style frame, resulting in an extremely stable, durable, and mobile power distribution platform. A center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGL-480D-30AFT-15KVA-2X208.30A-12X120.20A-20C -Temporary Power Distribution Ratings Line In: 20` #6 SOOW Cord Max Primary OCP: 55A @ 480V Primary Voltage: 480V AC 3PH Max PDU OCP: 25A @ 480V Primary Disconnects: (1) 30A 480V 3PH N3R Fused @ 30A, (1) 30A 480V 3PH N3R Fused @ 25A Max Secondary Output: 41.6A @ 208V Primary Receptacles: (1) 30A L16-30R [480V] UL 1640 Portable Power-Distribution Equipment Primary Protection: Time Delay Fuses, Disconnects, Weatherproof Cover NEMA 3R Indoor or Outdoor Use Transformer: 15 KVA 480V to 208Y/120V 3PH 60Hz N3R Made in the USA Secondary Voltage: 208Y/120V AC 3PH No Flat Tires Secondary Panel: 50A 208Y/120V 3PH MLO N3R Secondary Breakers: (2) 30A 3P [250V], (12) 20A 1P [125V] Special Orders- Requirements Secondary Outlets: (2) 30A L15-30R [250V], (12) 20A 5-20R GFCI [125V] Contact us for special requirements Secondary Protection: Circuit Breakers, GFCI, Weatherproof Covers Phone: 1-214-616-6180 Form Factor: Powder Coated Steel Dolly Cart Toll Free: 888-325-4448 Dimensions: W-40" X D-40" X H-48" Fax: 1-903-498-3364 Weight: 350 lbs E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase
Larson Electronics 15KVA Temporary Power Distribution - 480V to 208Y/120V 3PH - (1) L16-30R (2) L15-30R (12) 5-20R GFCI
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics 15KVA Temporary Power Distribution - 480V to 208Y/120V 3PH - (1) L16-30R (2) L15-30R (12) 5-20R GFCI
- SKU:
- MGL-480D-30AFT-15KVA-2X208.30A-12X120.20A-20C
- UPC:
- Weight:
- 0.00 LBS
!