Made in Texas The Larson Electronics MGL-208.3P-15KVA-240.3P-MOD1 temporary power distribution system converts three-phase 208V AC electrical current into three-phase 240V AC. This unit provides operators the ability to safely tap into and distribute 208V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use: The MGL-208.3P-15KVA-240.3P-MOD1 portable power distribution system gives operators the ability to power their 240 volt equipment from a single system. On the primary side, operators connect 208V using a customer-provided cord. On the secondary side, operators can connect equipment to a fused disconnect. Operation: A customer-provided cord brings three-phase 208V power to the NEMA 3R 60-amp 208V three phase primary disconnect, which contains three 60-amp time delay fuses, and passes 208V three phase power through to the transformer. The NEMA 3R 15 KVA transformer converts 208V to 240V three phase and passes the current to the secondary side. The secondary side of the transformer feeds a NEMA 3R 60-amp 240V three phase secondary disconnect, which contains three 40-amp time delay fuses. Protective Construction: The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style, frame resulting in an extremely stable, durable, and mobile power distribution platform. A dolly cart style mounting platform provides easier substation mobility, and a center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA, and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics` Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGL-208.3P-15KVA-240.3P-MOD1 -Temporary Power Distribution Ratings Line In: Customer-provided Cord Max Primary OCP: 60A @ 208V Primary Voltage: 208V AC 3PH Max Secondary Output: 40A @ 240V Primary Disconnect: 60A 208V 3PH N3R Fused @ 60A Max Secondary Output: 36.1A @ 240V Primary Protection: Disconnect, Time Delay Fuses UL 1640 Portable Power-Distribution Equipment Transformer: 15KVA 208V to 240V 3PH 60 Hz N3R NEMA 3R Indoor or Outdoor Use Secondary Voltage: 240V AC 3PH Made in the USA Secondary Disconnect: 60A 240V 3PH N3R Fused @ 40A Secondary Breakers: - Special Orders- Requirements Secondary Outlets: - Contact us for special requirements Secondary Protection: Disconnect, Time Delay Fuses Phone: 1-214-616-6180 Form Factor: Powder Coated Steel Dolly Cart Toll Free: 888-325-4448 Dimensions: W-40" X D-40" X H-48" Fax: 1-903-498-3364 Weight: 350 lbs E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250*Scroll Down to Purchase
Larson Electronics 15KVA Temporary Power Distribution - 208V to 240V 3PH - Dolly Cart w/o Tires - NEMA 3R
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics 15KVA Temporary Power Distribution - 208V to 240V 3PH - Dolly Cart w/o Tires - NEMA 3R
- SKU:
- MGL-208.3P-15KVA-240.3P-MOD1
- UPC:
- Weight:
- 0.00 LBS
!