Made in Texas The Larson Electronics MGL-60AFT.600-15KVA-8X120.20A-2X240.30A temporary power distribution system converts 600V AC electrical current into 120/240V single phase. This unit provides operators the ability to safely tap into and distribute 600V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use: The MGL-60AFT.600-15KVA-8X120.20A-2X240.30A portable power distribution system gives operators the ability to power their 600 volt, 240 volt and 120 volt equipment from a single system. On the primary side, operators connect three-phase 600V AC using a 25` #8 Type W cord and to one 460R5W receptacle for 600V equipment. On the secondary side, operators connect to two L6-30R receptacles for 240V equipment and to eight 5-20R GFCI quad receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 25` #8 Type W cord brings three-phase 600V power to the NEMA 3R 60-amp 600V three phase primary disconnect in a feed-through configuration, which contains three 60-amp time delay fuses protecting one 60-amp 600V 460R5W receptacle, and passes three-phase 600V power through to the second primary disconnect. The second disconnect on the primary side is a NEMA 3R 30-amp 600V three-phase unit, which contains two 30-amp time delay fuses, and passes single-phase 600V to the transformer. The NEMA 3R 15 KVA transformer converts 600V to 120/240V single phase and passes the current to the secondary side. The secondary side of the transformer feeds a NEMA 3R 100-amp single phase 120/240V main lug only panel. This secondary side contain two 30-amp 2-pole 250V breakers protecting two 30-amp 250V L6-30R receptacles and eight 20-amp 1-pole 125V breakers protecting eight 20-amp 125V 5-20R GFCI quad receptacles. Protective Construction: The transformer and load center/distribution assembly is mounted to a powder coated steel, dolly cart style frame resulting in an extremely stable, durable, and mobile power distribution platform. Equipped with a backplate, a dolly cart style mounting platform provides easier substation mobility; and a center point lift point allows easy lifting with cable or chain hooks. This temporary power distribution solution can be modified to meet the needs of job-site receptacle requirements. Units are available up to 150 KVA and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is NEMA 3R rated and ideal for indoor/outdoor use and applications including but not limited to; construction sites, plant maintenance, plant turnarounds, shows, exhibits and shipyard operations. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MGL-60AFT.600-15KVA-8X120.20A-2X240.30A -Temporary Power Distribution Ratings Line In: 25` #8 Type W Cord Max Primary OCP: 30A @ 600V Primary Voltage: 600V AC, 3PH Max Secondary Output: 62.5A @ 240V Primary Disconnects: (1) 60A 600V 3PH N3R Fused @ 60A FT, (1) 30A 600V 3PH N3R Fused @ 30A UL 1640 Portable Power-Distribution Equipment Primary Receptacles: (1) 60A 460R5W [600V] NEMA 3R Indoor or Outdoor Use Primary Protection: Disconnects, Time Delay Fuses, Weatherproof Cover Made in the USA Transformer: 15KVA 600V to 120/240V 1PH N3R Secondary Voltage: 120/240V AC, 1PH Secondary Panel: 100A 120/240V 1PH MLO N3R Secondary Breakers: (2) 30A 2P [250V], (8) 20A 1P [125V] Special Orders- Requirements Secondary Outlets: (2) 30A L6-30R [250V], (8) 20A 5-20R GFCI Quad [125V] Contact us for special requirements Secondary Protection: Circuit Breakers, Weatherproof Covers, GFCI Phone: 1-214-616-6180 Form Factor: Powder Coated Steel Dolly Cart w/ Backplate, No Flat Tires Toll Free: 888-325-4448 Dimensions: 24" x 24" Fax: 1-903-498-3364 Weight: 350 lbs E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase
Larson Electronics 15KVA Power Distribution - 600V to 120/240V 1PH - (11) Receptacles - 25' Type W Cord - No Flat Tires
Larson Electronics
(No reviews yet)
Write a Review
Write a Review
Larson Electronics
Larson Electronics 15KVA Power Distribution - 600V to 120/240V 1PH - (11) Receptacles - 25' Type W Cord - No Flat Tires
- SKU:
- MGL-60AFT.600-15KVA-8X120.20A-2X240.30A
- UPC:
- Weight:
- 0.00 LBS
!