Larson Electronics 15KVA Power Distribution - 480V to 240D/120V 3PH - (1) AR1031 (1) L15-20R (6) 5-20R GFCI Receptacles

Larson Electronics

(No reviews yet) Write a Review
SKU:
MPD-DC-480.100A-15KVA-1X240.20A-8X120.20A
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics MPD-DC-480.100A-15KVA-1X240.20A-8X120.20A temporary power distribution substation converts three-phase 480VAC electrical current into three phase 240D/120V. This unit provides operators the ability to safely tap into and distribute 480VAC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and UseThe MPD-DC-480.100A-15KVA-1X240.20A-8X120.20A portable power distribution system gives operators the ability to power their 480 volt, 240 volt and 120 volt equipment from a single system. On the primary side, operators bring three-phase 480V line-in power using 10` of #2 Type W cable with a APJ10377 cord cap and are provided access to one AR1031 receptacle for 480V equipment. On the secondary side, operators can access one L15-20R receptacle for 240VAC equipment and six 5-20R GFCI receptacles for 120V equipment. All receptacles are protected with weatherproof covers. Operation: A 10` #2 Type W cable with a 100-amp 600VAC rated APJ10377 cord cap brings 480V three phase power to a NEMA 3R 100-amp, 480V three phase primary disconnect, which contains 100-amp time delay fuses protecting one 100-amp 600VAC rated AR1031 receptacle. On the primary side, 480VAC three-phase is also distributed to a NEMA 3R 30-amp, 480V three phase primary disconnect, which contains 25-amp time delay fuses, and power is passed through to the transformer. The NEMA 3R 15 KVA transformer converts 480V to 240D/120V three phase and passes the current to the secondary panel. The secondary side of the transformer feeds a NEMA 3R 100-amp, 240D/120V three phase main lug only panel. This secondary panel contains one 20-amp, 3-pole, 250V breaker protecting one 20-amp, L15-20R, 250V receptacle, and six 20-amp, 1-pole, 125V breakers protecting six 20-amp, 5-20R, 125V GFCI receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. 1/8" metal sides prevent children and unwanted personel from accessing the load center. This model is equipped with forklift skid pockets, locking polyurethane casters, and a top located lifting eyelet which allows easy lifting with cable or chain hooks. This can be replaced for an additional cost with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs. Larger units are available upon request and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4x equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Larson Electronics is a manufacturer and as such can build portable transformer systems to your specifications. Although we carry several models of power distribution transformers, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MPD-DC-480.100A-15KVA-1X240.20A-8X120.20A -Temporary Power Distribution System Ratings Line In: 10` #2 Type W Cable UL 1640 Portable Power-Distribution Equipment Line In Cord Cap: 100A APJ10377 [600VAC Rated] NEMA 3R Indoor or Outdoor Use Primary Voltage: 480VAC 3PH Made in the USA Primary Disconnects: 480V 3PH 100A N3R Fused @ 100A, 480V 3PH 30A N3R Fused @ 25A Primary Receptacles: (1) 100A AR1031 [600VAC Rated] Primary Protection: Time Delay Fuses, Weatherproof Covers Transformer: 15KVA 480V to 240D/120V 3PH 60Hz N3R Secondary Voltage: 240D/120VAC 3PH Secondary Panel: 240D/120V 3PH 100A MLO N3R Secondary Breakers: (1) 20A 3P [250V], (6) 20A 1P [125V] Secondary Receptacles: (1) 20A L15-20R [250V], (6) 20A 5-20R GFCI [125V] Secondary Protection: GFCI, Weatherproof Covers Form Factor: Cube style with skid pockets, 8-inch locking casters, top pick eye, 1/8" cube wall Dimensions: 48” X 48” X 55” Weight: 700 lbs Special Orders- Requirements Max Primary OCP: 125A @ 480V Contact us for special requirements Max Rcpt. OCP: 100A @ 480V Toll Free: 888-325-4448 Max PDU OCP: 25A @ 480V Intl: 1-214-616-6180 Max Secondary Output: 36.1A @ 240V E-mail: [email protected] Larson Electronics manufacture a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews