Image coming soon

Larson Electronics 15KVA Power Distribution - 480V to 208Y/120V 3PH - (1) PHX 1645480 (1) L6-30R (6) L5-20R GFCI

Larson Electronics

(No reviews yet) Write a Review
SKU:
MPD-480.3P.50AFT.TB-15KVA-1X208.2P.30A-6X120.1P.20
Weight:
0.00 LBS
Call for price
Made in Texas The Larson Electronics MPD-480.3P.50AFT.TB-15KVA-1X208.2P.30A-6X120.1P.20A Power Distribution Substation converts 480V AC three phase electrical current into three phase 208Y/120V AC. This unit provides operators the ability to safely tap into and distribute 480V AC power from a variety of sources including generators and direct grid power. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Portable Power Distribution Purpose and Use: The MPD-480.3P.50AFT.TB-15KVA-1X208.2P.30A-6X120.1P.20A portable power distribution system gives operators the ability to power their 480 volt and 240 volt and 120 volt equipment from a single system. On the primary side, operators connect three phase 480V using 20` of #6 Type W cord with a 100-amp 4100P7W cord cap and to one Phoenix 1679427 terminal block 50-amp receptacle, protected by a Phoenix 1645480 housing, for 480V equipment. On the secondary side, operators may access one L6-30R receptacle for 240V equipment and six L5-20R GFCI duplex receptacles for 120V equipment. All receptacles are equipped with weatherproof covers. Operation: A 20` #6 Type W cord with a 100-amp 4100P7W cord cap brings 480V three phase power to the NEMA 3R 60-amp 480V three phase primary disconnect, which contains three 50-amp time delay fuses protecting one Phoenix 1679427 terminal block 50-amp 830V-rated receptacle, protected by a Phoenix 1645480 housing, and passes 480V three phase to the second primary disconnect. The NEMA 3R 30-amp 480V three phase second primary disconnect, which contains three 20-amp time delay fuses, passes 480V three phase power to the transformer. The NEMA 3R 15 KVA transformer converts 480V three phase power to 208Y/120V three phase 60 Hz and passes the current to the secondary side. The secondary side features a 50-amp 208Y/120V three phase main lug only NEMA 3R panel, which contains one 30-amp 2-pole 250V breaker protecting one 30-amp 250V L6-30R receptacle and six 20-amp 1-pole 125V breakers protecting six 20-amp 125V L5-20R GFCI duplex receptacles. Protective Construction: Unlike many portable power distribution boxes made of plastic and utilizing thin gauge, low grade metals in their construction, this unit is designed for serious use and is ruggedly constructed to withstand demanding conditions and heavy duty industrial applications. The transformer and load assembly is mounted on a 3/16" thick carbon steel mounting platform and the load center/distribution assembly is mounted to the standard 2" x 2" x 1/8" square carbon steel tubing frame, resulting in an extremely stable, durable and well protected power distribution platform. This model is equipped with forklift skid pockets, locking casters, and a top located lifting eyelet which allows easy lifting with cable or chain hooks. This can be replaced for an additional cost with stainless steel, hot dip galvanized steel, or aluminum depending on the customer’s needs. Larger units are available upon request and can be equipped with skids or trailer mounted. Certification: Larson Electronics is a UL 1640 panel shop and certified to build portable power distribution systems. All units are built in accordance to NFPA 70 (National Electric Code) and certified to UL 1640. All equipment is NEMA 3R rated for indoor and outdoor use and provide a degree of protection against dirt, water, and ice. NEMA 4 and NEMA 4X equipment can be equipped upon request. Grounding: Transformer is grounded to the frame and we provide a grounding lug on the frame for the earth ground. ~Please check all motor loads for dual rated motors that will work 208 or 240.~ Applications: This power distribution system is ideal for indoor or outdoor use and applications including but not limited to, construction sites, plant maintenance, plant turnarounds, shows, exhibits, and shipyard operations. These power distribution systems are popularly used in applications where external power sources are often necessary. We also offer class rated transformers for use within explosion proof and hazardous location environments. Custom Built Systems Available: Larson Electronics is a manufacturer and we can build portable power distribution systems to your specifications. Although we carry several models of portable power distribution systems in stock, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 888-325-4448 [email protected] to discuss your specific requirements. Specifications / Additional Information MPD-480.3P.50AFT.TB-15KVA-1X208.2P.30A-6X120.1P.20A Power Distribution Ratings Line-In Cord: 20` #6 Type W Cord Max OCP Primary: 70A @ 480V Line-In Cord Cap: 100A 4100P7W [480V] PDU Max OCP: 20A @ 480V Primary Voltage: 480V 3PH UL 1640 Portable Power-Distribution Equipment Primary Disconnects: (1) 60A 480V 3PH Fused @ 50A N3R, (1) 30A 480V 3PH Fused @ 20A N3R NEMA 3R Indoor / Outdoor Use Primary Panel: - Made in the USA Primary Breakers: - Primary Receptacles: (1) 50A Phoenix 1679427 Terminal Block Receptacle, Inside Phoenix 1645480 Housing [830V Rated] Primary Protection: Disconnects, Time Delay Fuses Transformer: 15 KVA 480V to 208Y/120V 3PH, 60 Hz N3R Secondary Voltage: 208Y/120V 3PH Secondary Disconnect: - Secondary Panel: 50A 208Y/120V 3PH MLO N3R Secondary Breakers: (1) 30A 2P [250V], (6) 20A 1P [125V] Secondary Receptacles: (1) 30A L6-30R [250V], (6) 20A L5-20R GFCI Duplex [125V] Special Orders- Requirements Secondary Protection: Breakers, Weatherproof Covers Contact us for special requirements Form Factor: Square tube frame, skid pockets, top pick eye, backplate & 8” locking casters Toll Free: 888-325-4448 Frame Materials: Powder coated steel frame Intl: 1-214-616-6180 Dimensions: 80"L x 44"W x 73"H Fax: 1-903-498-3364 Weight: 2000 pounds E-mail: [email protected] Larson Electronics manufactures a wide variety of custom power distribution systems. The pictures displayed for this unit are a general representation of form factor and may not accurately represent this exact configuration in every detail due to being custom builds. The specifics for this configuration are listed in the specification table and one-line diagram. *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250* Scroll Down to Purchase

Reviews