HPS Titan™ Series encapsulated transformers offer an innovative design with technological improvements for industrial and hazardous applications. The transformer core and coil is completely encapsulated in epoxy and silica, providing excellent protection from airborne contaminants and prevents the ingress of moisture. The three phase design has a removable hinged door and factory installed grounding lugs, reducing installation time and money.
HPS Titan Series is available in two lines:
HPS Titan N:
cULus Listed – approved for applications requiring UL and/or CSA certifications
HPS Titan X:
IECEx, ATEX, UKEx Certified – approved for applications requiring IEC conformity
HPS Titan™ N
- ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, T3 Hazardous Locations) - T3C/T3A Temperature Classification
HPS Titan™ X
- IEC 60079-0, IEC 60079-7,5.1 – Hazardous Locations Class I, Zone 2, Group IIC, T3
- 10kV BIL
- Copper with an electrostatic shield on all units
- 60 Hz (50/60Hz available)
- Ratings from 2 to 150 kVA three phase
- Temperature Rise 115°C, 95°C, 80°C at 180°C insulation class
- cULus Listed
- OSHPD Certified
- ABS type approval for Marine Duty
- Suitable for 50°C ambient while maintaining T3C/T3A Temperature Classification
- 10kV BIL
- Copper with an electrostatic shield on all units
- 60 Hz and/or 50/60 Hz
- Ratings from 6 to 75kVA three phase
- Temperature Rise 115°C, 80°C at 180°C insulation class
- IECEx, ATEX & UKEx Certified
- OSHPD Certified
- ABS type approval for Marine Duty
- Rated ambient temperature range (°C) -25°C to +40°C
- Standard Glass Filled Naylon Condensate Valve
HPS Titan™ N
- ANSI/ISA 12.12.10 - File No. E258346 (Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, T3 Hazardous Locations) - T3C/T3A Temperature Classification
- 10kV BIL
- Copper with an electrostatic shield on all units
- 60 Hz (50/60Hz available)
- Ratings from 2 to 150 kVA three phase
- Temperature Rise 115°C, 95°C, 80°C at 180°C insulation class
- cULus Listed
- OSHPD Certified
- ABS type approval for Marine Duty
- Suitable for 50°C ambient while maintaining T3C/T3A Temperature Classification
HPS Titan™ X
- IEC 60079-0, IEC 60079-7,5.1 – Hazardous Locations Class I, Zone 2, Group IIC, T3
- 10kV BIL
- Copper with an electrostatic shield on all units
- 60 Hz and/or 50/60 Hz
- Ratings from 6 to 75kVA three phase
- Temperature Rise 115°C, 80°C at 180°C insulation class
- IECEx, ATEX & UKEx Certified
- OSHPD Certified
- ABS type approval for Marine Duty
- Rated ambient temperature range (°C) -25°C to +40°C
- Standard Glass Filled Naylon Condensate Valve
Advantages of IECEx Certification*
(Available with HPS Titan X) - IECEx Certificates (iecex-certs.com)
There is an increasing need for installation efficiency and safety in industrial automation and hazardous locations. Electrical equipment and their use in these areas are covered by a wide range of IEC Standards and are generally highly regulated.
The use of the IECEx Conformity Assessment System and its Schemes offer some key advantages:
Safety
Equipment, installations and systems are manufactured, operated and maintained in compliance with IEC International Standards.
Simple Online Verification
All issued IECEx Certificates are available for verification on www.iecex.com or on the IECEx app.
UN endorsement
The United Nations, via UNECE, has endorsed IECEx as the internationally-recognized certification system for promoting the improved safety of equipment, services and personnel associated with devices, systems and installations used in Ex areas.
Cost reductions
IECEx certification reduces the need for additional testing and certification which can lower costs and streamline processes.