Fluke T5-600/62MAX+/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit

Fluke

$369.99
(No reviews yet) Write a Review
SKU:
FLUKE-T5-600-62-Max-Plus
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke T5-600/62MAX+/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit

This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.



Key features

Fluke T5 Voltage, Continuity and Current Testers.

  • Automatically measures volts AC and volts DC with precise digital resolution.
  • Displays resistance to 1000 ½.
  • Easy and accurate OpenJaw current measurement.
  • Continuity beeper.
  • Rugged enough to withstand a 10 ft (3 m) drop.
  • 600 V model.
  • Auto off mode to conserve battery life.
  • AC current.
  • Display hold.
  • All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3 m (9.8 ft) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.
  • C115 Deluxe soft carrying case with shoulder strap.


Fluke T5-600 Voltage, Continuity and Current Tester

Specifications
Jaw opening12.9 mm (0.5 in)
Max wire size1/0 THHN cable
Current range AC rms0 to 100.0 A
Accuracy AC current (50/60 Hz)3% ± 3 counts
AC ResponseAveraging
Voltage range AC0 to 600 V
Accuracy AC voltage1.5% ± 2 counts
Voltage range DC0 to 600 V
Accuracy DC voltage1% ± 1 count
Resistance range0 to 1000 ½
Continuity beeper thresholdOn at < 25 ½, off at > 400 ½
Volts indicator LED thresholdGuaranteed on by 30 V AC
Environmental Specifications
Operating temperature-10¡C to 50¡C
Storage temperature-30¡C to 60¡C
Humidity (without condensation)0% to 95% (5¡C to 30¡C); 0% to 75% (30¡C to 40¡C);
0% to 45% (40¡C to 50¡C)
Dust/water resistanceYes
Operating altitude2000 meters max
Temperature coefficient0.1 x (specified accuracy)/¡C (< 18¡C or > 28¡C)
Safety Specifications
Measurement CategoryIEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac
Agency approvalsCSA, TUV
Maximum voltage600 V between any terminal and earth ground
Mechanical and General Specifications
Size30.5 x 51 x 203 mm
Weight300 g
WarrantyTwo-years
Battery life200 hour zinc chloride, 400 hour alkaline
Battery type2 x AA
Low battery indicatorYes
Current sensor opening12.9 mm
Calibration cycle1 year
Test leadsTypeHeavy duty, flexible leads rated for 1000 V use.
Field replaceable leads terminate in male shrouded banana plugs
ProbesOne red, one black.
Detachable Slim-Reach probe tips
StylesTP1 Slim Reach test brobes
Safety Specifications
SafetyCAT IV 600 V, CAT III, 1000 V
Maximum voltage1000 V AC rms from earth to ground, in compliance with EN61010


Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range-30¡C to 650¡C (-22¡F to 1202¡F)
Accuracy±1.0¡C or ±1.0% of reading, whichever is greater
-10¡C to 0¡C: ±2.0
-30¡C to -10¡C: ±3.0
Response time (95%)< 300 ms (95% of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Optical resolution12:1 (calculated at 90% energy)
Display resolution0.1¡C (0.2¡F)
Repeatability of readings±0.5% of reading or < ±0.5¡C (1¡F), whichever is greater
PowerAA battery
Battery life8 hours with laser and backlight on
Physical Specifications
Weight255 g (8.99 oz)
Size175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature0¡C to 50¡C (32¡F to 122¡F)
Storage temperature-20¡C to 60¡C (-4¡F to 140¡F), (without battery)
Operating humidity10% to 90% RH non-condensing at 30¡C (86¡F)
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
IP ratingIP 54 per IEC 60529
Drop test3 meters
Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMCEN 61326-1:2006 EN 61326-2:2006
Standards and agency approvalComplianceEN/IEC 61010-1: 2001
Laser safetyFDA and EN 60825-1 Class II