Designed for PV professionals, the SMFT-1000 solar tools kit provides a complete solution for PV installation, commissioning, inspection, and maintenance testing that conforms to IEC 62446-1 standards. Through FlukeÕs TruTest Software, measurement data from solar site installation and commissioning testing can be easily imported, organized and analyzed for effortless reporting without having to bring a laptop on-site.
Category 1 Ð IEC 62446-1 full sequence safety testingÊ
- Protective resistance earth (Rpe)Ê
- Voltage on open circuit (Voc)Ê
- Short circuit current (Isc)Ê
- Insulation resistance (Rins)
- Polarity
Category 2 Ð IEC 62446-1 system performance testingÊ
While taking an I-V curve reading in the field, the SMFT-1000 will display the curve as it loads in the test data, against the module specifications as defined by the manufacturer. This makes it easy to immediately confirm measurements without the use of a laptop or tablet. Run the I-V curve test on new installations to confirm they are working according to the site specifications, or to test if existing modules or strings are working to their expected performance levels.
- I-V Curve tracing and software analysis with TruTest
- Irradiance, temperature, tilt, cardinal direction
Wireless Irradiance Meter
To perform precise I-V curve measurements, real time irradiance and temperature data is needed. The SMFT-1000 Solar Tools Kit includes the IRR2-BT irradiance meter wirelessly connects to the SMFT-1000 to communicate data in real time, providing the most accurate I-V curve measurements possible. If the wireless connection is interrupted for any reason, the IRR2-BT will continue recording data for up to 17 hours that can later be matched to tests taken with the SMFT-1000.Ê
TruTest Advanced Solar Software: Spend less time processing test results and compiling reports
Cover all your certification and documentation needs through the fast and reliable TruTest software. TruTest integrates solar asset management, data storage and reporting on a single platform. Whether you are analyzing panel efficiency through I-V curves, or safety testing the system through the Category 1 test regime in conformance to IEC 62446-1, proper data management is critical for producing easy-to-understand reports for clients. TruTest Software allows you to quickly and easily import measurement results directly from your solar multifunction tester to your computer, organize and analyze the data, compare individual asset data against previous measurements imported and provide a comprehensive and visual client report.
- Easily manage measurement data from solar site installation and commissioning testingÊ
- Quickly create inspections and reports compliant with IEC 62446-1 and other directives
- I-V curve analysis with easy pass/fail visuals; see changes in I-V curve over multiple site visits
- Compare site data to previous site data to see changes over time
Key features
- All-in-one solar PV system testing solution meeting IEC 62446-1 standards for Category 1 and Category 2 tests
- Kit includes TruTest Advanced Software for solar asset management and MC4 Solar Clamp Test Lead Set
- Compare on-location I-V curve results with manufacturer I-V curve dataÊ
- Irradiance meter connection for precise real-time irradiance and temperature measurements
Fluke SMFT-1000 Multifunction PV Analyzer
Ê | Ê | Ê | Ê |
Protective conductor resistance (RLo) | |||
Display range | Measuring range | Resolution | Accuracy |
0.00 ½ - 19.99 ½ | 0.20 ½ - 19.99 ½ | 0.01 ½ | ± (2 % + 2 Digit) |
20.0 ½- 199.9 ½ | 20.0 ½ - 199.9 ½ | 0.1 ½ | ± (2 % + 2 Digit) |
200 ½ - 2000 ½ | 200 ½ - 2000 ½ | 1 ½ | ± (5 % + 2 Digit) |
Ê | Ê | Ê | Ê |
Test current | ³ 200 mA (² 2½ + Rcomp) | Ê | Ê |
Test voltage | 4 V DC É 10 V DC | Ê | Ê |
Polarity reversing | Yes | Ê | Ê |
Test lead zero (Rcomp) | Up to 3 ½ | Ê | Ê |
Ê | Ê | Ê | Ê |
PV module/PV string, open-circuit voltage (Voc) | |||
Display range | Measuring range | Resolution | Accuracy |
0.0 V - 99.9 V | 5.0 V - 99.9 V | 0.1 V | ± (0.5 % + 2 Digit) |
100 V - 1000 V | 100 V - 1000 V | 1 V | ± (0.5 % + 2 Digit) |
Ê | Ê | Ê | Ê |
Polarity test | Yes | Ê | Ê |
Ê | Ê | Ê | Ê |
PV module/PV string, short-circuit current (Is/c) | |||
Display range | Measuring range | Resolution | Accuracy |
0.0 A - 20.0 A | 0.2 A - 20.0 A | 0.1 A | ± (1 % + 2 Digit) |
Ê | Ê | Ê | Ê |
Insulation resistance (RINS) | |||
Display range | Measuring range | Resolution | Accuracy |
0.00 M½ - 99.99 M½ | 0.20 M½ - 99.99 M½ | 0.01 M½ | ± (5 % + 5 Digit) |
100.0 M½ - 199.9 M½ | 100.0 M½ - 199.9 M½ | 0.1 M½ | ± (10 % + 5 Digit) |
200 M½ - 999 M½ | 200 M½ - 999 M½ | 1 M½ | ± (20 % + 5 Digit) |
Ê | Ê | Ê | Ê |
Ê | Measuring range | Resolution | Accuracy |
Test voltage @ no load | 50 V / 100 V / 250 V up to 199.9 M½ 500 V / 1000 V up to 999 M½ | 1 V | 0 % to + 20 %Ê |
Test voltage @ ³ 1 mA | 250 V @ 250 k½ 500 V @ 500 k½ 1000 V @ 1 M½ | 1 V | 0 % to + 10 % |
Testing current | Min. 1 mA (@ 250 k½ / 500 k½ / 1 M½) Max. 1.5 mA (short circuit) | Ê | Ê |
Ê | Ê | Ê | Ê |
Blocking diode checking (Vbd) | |||
Display range | Measuring range | Resolution | Accuracy |
0.00 V DC - 6.00 V DC | 0.50 V DC - 6.00 V DC | 0.01 V DC | ± (5 % + 10 Digit) |
Ê | Ê | Ê | Ê |
Surge protection device (SPD) | |||
Display range | Measuring range | Resolution | Accuracy |
0 V DC - 1000 V DC | 50 V DC - 1000 V DC | 1 V DC | ± (10 % + 5 Digit) |
Ê | Ê | Ê | Ê |
Ê | Ê | Ê | Ê |
AC/DC voltage measurement via 4 mm test sockets | |||
Display range | Measuring range | Resolution | Accuracy |
0.0 V AC - 99.9 V AC | 5.0 V AC - 99.9 V AC | 0.1 V | ± (2.5 % + 2 Digit) |
100 V AC - 700 V AC | 100 V AC - 700 V AC | 1 V | ± (2.5 % + 2 Digit) |
0.0 V DC - 99.9 V DC | 5.0 V DC - 99.9 V DC | 0.1 V | ± (2.5 % + 2 Digit) |
100 V DC - 1000 V DC | 100 V DC - 1000 V DC | 1 V | ± (2.5 % + 2 Digit) |
Ê | Ê | Ê | Ê |
Detection AC/DC | Yes (Automatic) | Ê | Ê |
+ / - polarity check | Yes | Ê | Ê |
Ê | Ê | Ê | Ê |
AC/DC current with i100 clamp | |||
Display range | Measuring range | Resolution | Accuracy (DC, AC 50 Hz/60 Hz) |
0.0 A DC Ð 100 A DC | 1.0 A DC Ð 100 A DC | 0.1 A | ± (5 % + 2 Digit) * |
0.0 A AC Ð 100 A AC TRMS | 1.0 A AC Ð 100 A AC TRMS | 0.1 A | ± (5 % + 2 Digit) * |
* i100 clamp tolerances not inclusive | Ê | Ê | Ê |
Ê | Ê | Ê | Ê |
i100 Clamp Tolerances | |||
Display range | Measuring range | Output signal | Accuracy (DC, AC 50 Hz/60 Hz) |
N/A | 1 A - 100 A DC or AC < 1 kHz | 10 mV/A AC/DC | ± (1.5 % + 0.1 A)Ê |
Ê | Ê | Ê | Ê |
Ê | Ê | Ê | Ê |
AC/DC Power measurement (with i100 clamp) | |||
Display range | Measuring range | Resolution | Accuracy (DC, AC 50 Hz/60 Hz) |
0.0 V AC - 700 V AC 0.0 V DC - 1000 V DC | 5.0 V AC - 700 V AC 5.0 V DC - 1000 V DC | 0.1 V | ± (2.5 % + 2 Digit) |
0 A AC/DC - 100 A AC/DC | 1 A AC/DC- 100 A AC/DC | 0.1 A | ± (6.5 % + 3 Digit) |
0 kW/kVA Ð 100 kW/kVA | 5 kW/kVA Ð 100 kW/kVA | 1 kW/kVA | ± (10 % + 4 Digit) |
Ê | Ê | Ê | Ê |
Ê | Ê | Ê | Ê |
Ê | Ê | Ê | Ê |
General Specifications | Ê | Ê | |
SMFT-1000 size | 10 cm x 25.0 cm x 12.5 cm (3.8 in x 9.8 in x 4.9 in) | Ê | Ê |
SMFT-1000 weight | 1.4 kg (3.09 lb) | Ê | Ê |
Battery | 6 AA IEC LR6 | Ê | Ê |
Operating temperature | 0 ¡C to 50 ¡C (32 ¡F to 122 ¡F) | Ê | Ê |
Storage temperature | -30 ¡C to 60 ¡C (-22 ¡F to 140 ¡F) batteries removed | Ê | Ê |
Operating altitude | up to 2000 m | Ê | Ê |
Storage altitude | up to 2000 m | Ê | Ê |
Safety | Ê | Ê | |
SMFT-1000 PV Analyzer | IEC 61010-1 Pollution Degree 2 IEC 61010-2-034 CAT III 1000 V dc, CAT III 700 V AC | Ê | Ê |
i100 Current Clamp | IEC 61010-2-032, Type D (for insulated conductors), 1000 V | Ê | Ê |
Accessories | IEC 61010-031 | Ê | Ê |
TL1000-MC4 | CAT III 1500 V, 20 A | Ê | Ê |
TP1000 Remote Probe (with cap) | CAT IV 600 V, CAT III 1000 V, 10 A | Ê | Ê |
TP1000 Remote Probe (without cap) | CAT II 1000 V, 10 A | Ê | Ê |
TL1000 Test Leads | CAT III 1000 V, 10 A | Ê | Ê |
TL1000/30M Test Leads | CAT III 1000 V, CAT IV 600 V, 5 A (on reel) 10 A (fully extended) | Ê | Ê |
TP74 Test Probes (with cap) | CAT III 1000 V, 10 A | Ê | Ê |
TP74 Test Probes (without cap) | CAT II 1000 V, 10 A | Ê | Ê |
AC285 Alligator Clip | CAT III 1000 V, 10 A | Ê | Ê |
Performance | IEC 61557-1, IEC 61557-2, IEC 61557-4, IEC 61557-10 | Ê | Ê |
Electromagnetic Compatibility (EMC) | Ê | Ê | |
International | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | Ê | Ê |
Wireless Radio Module | Ê | Ê | |
Frequency Range | 2.402 GHz to 2.480 GHz | Ê | Ê |
Output Power | 8 dBm | Ê | Ê |