Fluke 725Ex provides an intrinsically safe, simple and powerful multifunction calibration solution
The 725Ex is an intrinsically safe multifunction process calibrator for use in explosion endangered areas. It is powerful, yet easy to use. Combine the 725EX with any of the eight Fluke 750PEx Pressure Modules (sold separately), and youÕll be able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present.
The 725EX sources and measures almost all process parameters including mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Its split display lets you view input and output values simultaneously to calibrate transmitters. For valve and I/P tests, you can source mA while measuring pressure. The 725Ex has auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast linearity tests.
From the moment you pick it up, the Fluke 725Ex is ready to perform. Its simple controls, without menus, make operation easy. Its memory functions make set up fast. And its rugged design lets it work as hard as you do.
Other useful features:
- Pressure switch test function to capture set, reset, and deadband values
- Small, streamlined shape, and rugged, reliable design that stands up to field use
- Simple, push-button user interface for easy operation
- Provides two-channel simultaneous source and measure capability to calibrate transmitters
- Powers transmitters during test using loop supply
- Stores frequently-used test setups for later use
- Measures pressure to 3,000 psi/200 bar using any of the eight intrinsically safe Fluke 700PEx Pressure Modules to calibrate pressure transmitters and I/P devices
Key features
- Intrinsically safe multifunction process calibrator
- Meets I.S. Class I, Division 1 Groups B-D, 171¡C compliance standards
- Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
- Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms
Measurement Accuracy | ||
Voltage DC | 30.000 V | 0.02% + 2 counts (upper display) |
10.000 V | 0.02% + 2 counts (lower display) | |
90.00 mV | 0.02% + 2 counts | |
-10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
Current DC | 24.000 mA | 0.02% + 2 counts |
Resistance | 0.0 to 400.0 ½ | 0.1 ½ (4-wire), 0.15 ½ (2- and 3-wire) |
401 to 1500 ½ | 0.5 ½ (4-wire), 1 ½ (2- and 3-wire) | |
1500 to 3200 ½ | 1 ½ (4-wire), 1.5 ½ (2- and 3-wire) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% + 1 count |
1.0 to 1100.0 Hz | 0.05% + 1 count | |
1.00 to 10.00 kHz | 0.05% + 1 count | |
Sensitivity | 1 V peak-to-peak-minimum | |
Pressure | Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. | |
Source Accuracy | ||
Voltage DC | 100.00 mV | 0.02% + 2 counts |
10.000 V | 0.02% + 2 counts | |
-10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
Current DC | 24.000 mA (source) | 0.02% + 2 counts |
24.000 mA (simulate) | 0.02% + 2 counts | |
Resistance | 15.0 to 400.0 ½ | 0.15 ½ (exc. current 0.15 to 0.5 mA), 0.1 ½ (exc. current 0.5 to 2 mA) |
401 to 1500 ½ | 0.5 ½ (excitation current 0.05 to 0.8 mA) | |
1500 to 3200 ½ | 1 ½ (excitation current 0.05 to 0.4 mA) | |
Frequency | 2.0 to 1000.0 CPM | 0.05% |
1.0 to 1100.0 Hz | 0.05% | |
1.00 to 10.00 kHz | 0.25% | |
Waveform | 5 V p-p squarewave, -0.1 V offset | |
RTDs and Thermocouples | ||
Measure accuracy | NI-120 | 0.2¡C |
PT-100 (385) | 0.33¡C | |
PT-100 (393) | 0.3¡C | |
PT-100 (JIS) | 0.3¡C | |
PT-200 (385) | 0.2¡C | |
PT-500 (385) | 0.3¡C | |
PT-1000 (385) | 0.2¡C | |
Resolution | 0.1¡C | |
J | 0.7¡C | |
K | 0.8¡C | |
T | 0.8¡C | |
E | 0.7¡C | |
R | 1.8¡C | |
S | 1.5¡C | |
B | 1.4¡C | |
L | 0.7¡C | |
U | 0.75¡C | |
N | 0.9¡C | |
Resolution | J, K, T, E, L, N, U: 0.1¡C, 0.1¡F B, R, S: 1¡C, 1¡F | |
XK | 0.6¡C | |
BP | 1.2¡C | |
Source accuracy | NI-120 | 0.2¡C |
PT-100 (385) | 0.33¡C | |
PT-100 (393) | 0.3¡C | |
PT-100 (JIS) | 0.3¡C | |
PT-200 (385) | 0.2¡C | |
PT-500 (385) | 0.3¡C | |
PT-1000 (385) | 0.2¡C | |
Resolution | 0.1¡C | |
Accuracy stated for 4-wire measurement. | ||
J | 0.7¡C | |
K | 0.8¡C | |
T | 0.8¡C | |
E | 0.7¡C | |
R | 1.4¡C | |
S | 1.5¡C | |
B | 1.4¡C | |
L | 0.7¡C | |
U | 0.75¡C | |
N | 0.9¡C | |
Resolution | J, K, T, E, L, N, U: 0.1¡C, B, R, S: 1¡C | |
XK | 0.6¡C | |
BP | 1.2¡C | |
Specifications | ||
Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
Ramps | Slow ramp, Fast ramp, 25% step-ramp | |
Loop power function | Voltage | 12 V |
Accuracy | 10% | |
Maximum current | 22 mA, short circuit protected | |
Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
Steps | 25% of range, 100% of range | |
Safety specifications | ||
Agency approvals | I.S. Class I, Division 1 Groups B-D | |
Mechanical and General Specifications | ||
Size | 130 x 236 x 61 mm (5.188 x 9.291 x 2.402 in) | |
Weight | 0.85 kg (1.874 lbs.) | |
Batteries | 4 AA alkaline batteries | |
Warranty | Three year | |
Battery replacement | Separate battery compartment, accessible without breaking calibration seal | |
Side port connections | Pressure module connector |