Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

Fluke

$1,409.99
(No reviews yet) Write a Review
SKU:
FLUKE-1587-Mdt-Fc-Kit
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:

  • Pl/DAR timed ratio tests with TrendIt graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect¨ Assets

The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

Fluke 9040 Phase Rotation Indicator is effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.



Key features

Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator

  • With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
  • Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit
  • Check the rotation of three-phase motors easily and safely with the Fluke 9040

The Fluke 1587 FC 2-in-1 Insulation DMM

  • Pl/DAR measurements with TrendIt graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test voltages 500 V, 1000 V
  • Insulation test: 0.01 M½ to 2.0 G½
  • Insulation test: 0.1 M½ to 600 M½
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency / Capacitance / Diode test / Temperature
  • Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
  • Resistance (0.1 ½ to 50 M½) / Continuity / Auto power off
  • Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case

Fluke i400 AC Current Clamp

  • Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
  • 1 mA/Amp output guarantees easy reading
  • CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
  • Specially designed to offer maximum utility in a very compact shape
  • Maximum conductor: ¯ 32 mm
  • 1 year warranty

Fluke 9040 Phase Rotation Indicator

  • Large display to easily determine field rotation and phase sequence
  • Indication for all three phases
  • CAT III 600 V overvoltage rating
  • 2 year warranty


Fluke 1587 FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mVResolution0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
6.000 VResolution0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
60.00 VResolution0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
600.0 VResolution0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)_
1000 VResolution1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)_
_ 1 kHz bandwidth
Low-Pass Filter VoltageÊ
Range
600.0 mVResolution0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
6.000 VResolution0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
60.00 VResolution0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
600.0 VResolution0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
1000 VResolution1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
DC Voltage Measurement
RangeResolutionAccuracy ±(% of Rdg + Counts)
6.000 V dc0.001 V±(0.09% + 2)
60.00 V dc0.01 V±(0.09% + 2)
600.0 V dc0.1 V±(0.09% + 2)
1000 V dc1 V±(0.09% + 2)
Input impedanceÊ10 M½ (nominal), <100 pF
Normal mode rejection ratioÊ>60 dB @ 50 Hz or 60 Hz
Common mode rejection ratioÊ>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
RangeResolutionAccuracy ±(% of Rdg + Counts)
600.0 mVdc0.1 mV±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range400 mA
Resolution0.1 mA
Accuracy ±(% of Rdg+Counts)±(1.5% + 2)_
Burden voltage (Typical)2 mV/mA
Range60 mAÊ
Resolution0.01 mAÊ
Accuracy ±(% of Rdg+Counts)±(1.5% + 2)_
Burden voltage (Typical)2 mV/mA
DC
Range400 mA
Resolution0.1 mA
Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
Burden voltage (Typical)2 mV/mA
Range60 mA
Resolution0.01 mA
Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
Burden voltage (Typical)2 mV/mA
Overload600 mA for 2 minutes maximum
Fuse protection for mA input0.44 mA, 1000 V, IR 10 kA
AC conversionInputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ²1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
_ 1 kHz bandwidth
Ohms Measurement
RangeResolutionAccuracy +(% of Rdg+Counts)_
600.0 ½0.1 ½±(0.9% + 2)
6.000 k½0.001 k½±(0.9% + 2)
60.00 k½0.01 k½±(0.9% + 2)
600.0 k½0.1 K½±(0.9% + 2)
6.000 M½0.001 M½±(0.9% + 2)
50.0 M½ _0.01 M½±(1.5% + 3)
Overload protectionÊ1000 V rms or dc
Open circuit test voltageÊ<8.0 V dc
Short circuit currentÊ<1.1 mA
_ Accuracies apply from 0% to 100% of range
_ Up to 80% relative humidity
Diode Test
Diode test indicationDisplay voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy±(2% + 3)
Continuity Test
Continuity indicationContinuous audible tone for testresistance below 25 ½ and off above 100 ½. Maximum Reading; 1000 ½
Open circuit voltage<8.0 V
Short circuit current1.0 mA typical
Overload protection1000 V rms
Response time>1 m sec
Frequency Measurement
RangeResolutionAccuracy ±(% of Rdg+Counts)
99.99 HzÊ0.01 Hzʱ(0.1% + 1)
999.9 HzÊ0.1 Hzʱ(0.1% + 1)
9.999 kHzÊ0.001 kHzʱ(0.1% + 1)
99.99 kHzÊ0.01 kHzʱ(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV acÊV ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ100.0 mVÊ
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz150.0 mVÊ
DC Trigger Levels_ to 20 kHz_NA
6.0 VÊV ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ1.0 VÊ
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz1.5 VÊ
DC Trigger Levels_ to 20 kHz_-400.0 mV and 2.5 V
60.0 VÊV ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ10.0 VÊ
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz36.0 VÊ
DC Trigger Levels_ to 20 kHz_1.2 V and 4.0 V
600.0 VÊV ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ100.0 VÊ
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz-
DC Trigger Levels_ to 20 kHz_12.0 V and 40.0 V
1000.0 VÊV ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ300.0 VÊ
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz-
DC Trigger Levels_ to 20 kHz_12.0 V and 40.0 V
_ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
_ Usable to 100 kHz with full scale input
Capacitance
RangeÊResolutionÊAccuracy ±(% of Rdg+Counts)
1000 nFÊ1 nF±(1.2% + 2)
10.00 _FÊ0.01 _F±(1.2% + 2)
100.0 _FÊ0.1 _F±(1.2% ±90 counts)
9999 _FÊ1 _F±(1.2% ±90 counts)
Temperature Measurement
RangeÊResolutionÊAccuracy ±(% of Rdg+Counts)_
-40 ¡ C to 537 ¡ CÊ0.1 ¡Cʱ(1% + 10 counts)
-40 ¡ F to 998 ¡ FÊ0.1 ¡Fʱ(1% + 18 counts)
_ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Measurement range0.01 M½ to 2 G½
Test voltages50, 100, 250, 500, 1000 V
Test voltage accuracy+20%, -0%
Short-circuit test current1 mA nominal
Auto dischargeDischarge time <0.5 second for C = 1 _F or less
Live circuit detectionInhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive loadOperable with up to 1 _F load
Output Voltage
50 V (0% to +20%)Display range0.01 to 6.00 M½
Resolution0.01 M½
Test current1 mA @ 50 k½
Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
Display range6.0 to 50.0 M½
Resolution0.1 M½
Test current1 mA @ 50 k½
Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
100 V (0% to +20%)Display range0.01 to 6.00 M½
Resolution0.01 M½
Test current1 mA @ 100 k½
Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
Display range6.0 to 60.0 M½
Resolution0.1 M½
Test current1 mA @ 100 k½
Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
Display range60 to 100 M½Ê
Resolution1 M½
Test current1 mA @ 100 k½
Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
250 V (0% to +20%)Display range0.1 to 60.0 M½Ê
Resolution0.1 M½
Test current1 mA @ 250 k½Ê
Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
Display range60 to 250 M½Ê
Resolution1 M½
Test current1 mA @ 250 k½Ê
Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
500 V (0% to +20%)Display range0.1 to 60.0 M½
Resolution0.1 M½
Test current1 mA @ 500 k½Ê
Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
Display range60 to 500 M½
Resolution1 M½
Test current1 mA @ 500 k½Ê
Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
1000 V (0% to +20%)Display range0.1 to 60.0 M½Ê
Resolution0.1 M½
Test current1 mA @ 1 M½
Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
Display range60 to 600 M½Ê
Resolution1 M½
Test current1 mA @ 1 M½
Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
Display range0.6 to 2.0 G½Ê
Resolution100 M½Ê
Test current1 mA @ 1 M½
Resistance accuracy ±(% of Rdg + Counts)±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common1000 V
Storage temperature-40 ¡C to 60 ¡C (-40 ¡F to 140 ¡F)
Operating temperature-20 ¡C to 55 ¡C (-4 ¡F to 131 ¡F)
Temperature coefficient0.05 x (specified accuracy) per ¡C for temperatures <18 ¡C or >28 ¡C (<64 ¡F or >82 ¡F)
Relative humidityNoncondensing
0% to 95% @ 10 ¡C to 30 ¡C (50 ¡F to 86 ¡F)
0% to 75% @ 30 ¡C to 40 ¡C (86 ¡F to 104 ¡F)
0% to 40% @ 40 ¡C to 55 ¡C (104 ¡F to 131 ¡F)
VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication2.4 GHz ISM Band
Radio frequency certificationFCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic CompatibilityÊ
InternationalIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.Ê There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protectionIEC 60529: IP40 (non-operating)
Safety
IEC 61010-1Pollution Degree 2
IEC 61010-2-033CAT IV 600 V / CAT III 1000 V
BatteriesÊFour AA batteries (NEDA 15A or IEC LR6)
Battery lifeMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M½ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight550 g (1.2 lb)
AltitudeOperating2000 m
Storage12,000 m
Over-range capability110% of range except for capacitance which is 100%
Frequency overload protection<107 V Hz
Fuse protection for mA input0.44A, 1000 V, IR 10 kA

Fluke i400 AC Current Clamp

Specifications
Nominal current range400Ê A
Continuous current range1 A - 400 A
Maximum non-destructive current1000 A
Lowest measurable current1 A
Basic accuracy2% + 0.06 A
(45-400 Hz)
(% reading + floorspec)
Useable frequency5 Hz - 20 kHz
Output level(s)1 mA/A
Safety Specifications
SafetyCAT IV 600 V, CAT III, 1000 V
Maximum voltage1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty1 year
Maximum conductor diameter32 mm (1.25 in)
Maximum conductor size (busbar)750 MCM
Output cable length1.5 m (59 in)
Shrouded banana plugsYes

Fluke 9040 Phase Rotation Indicator

Technical Specifications
Voltage range40-700 V
Frequency range15-400 Hz
Operating timerContinuous
Environmental Specifications
Operating temperature0 ¡C to 40 ¡C
Dust/water resistanceIP 40
Safety Specifications
Electrical safetyEN 61010, ÊEN 61557-7
Overvoltage categoryCAT III, 600 V
CAT IV, 300V
Mechanical and General Specifications
Size124 x 61 x 27 mm
Weight200 g
Power supplyFrom unit under test
Warranty2 years

Reviews