The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:
- Pl/DAR timed ratio tests with TrendIt graphs identifies moisture and contaminated insulation problems faster
- Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
- Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
- Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect¨ Assets
The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.
Fluke 9040 Phase Rotation Indicator is effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.
Key features
Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator
- With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
- Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit
- Check the rotation of three-phase motors easily and safely with the Fluke 9040
The Fluke 1587 FC 2-in-1 Insulation DMM
- Pl/DAR measurements with TrendIt graphs
- Memory storage through Fluke Connect Measurements app
- Temperature Compensation through Fluke Connect Measurements app
- VFD low-pass filter for accurate motor drive measurements
- Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
- Insulation test voltages 500 V, 1000 V
- Insulation test: 0.01 M½ to 2.0 G½
- Insulation test: 0.1 M½ to 600 M½
- Auto-discharge of capacitive voltage
- Insulation test smoothing reading
- Frequency / Capacitance / Diode test / Temperature
- Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
- Resistance (0.1 ½ to 50 M½) / Continuity / Auto power off
- Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case
Fluke i400 AC Current Clamp
- Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
- 1 mA/Amp output guarantees easy reading
- CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
- Specially designed to offer maximum utility in a very compact shape
- Maximum conductor: ¯ 32 mm
- 1 year warranty
Fluke 9040 Phase Rotation Indicator
- Large display to easily determine field rotation and phase sequence
- Indication for all three phases
- CAT III 600 V overvoltage rating
- 2 year warranty
Fluke 1587 FC Insulation Multimeter
Electrical Specifications | ||
AC voltage measurement | ||
Range | ||
600.0 mV | Resolution | 0.1 mV |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3) | |
6.000 V | Resolution | 0.001 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3) | |
60.00 V | Resolution | 0.01 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3) | |
600.0 V | Resolution | 0.1 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3)_ | |
1000 V | Resolution | 1 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(2% + 3) | |
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3)_ | |
_ 1 kHz bandwidth | ||
Low-Pass Filter VoltageÊ | ||
Range | ||
600.0 mV | Resolution | 0.1 mV |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) | |
6.000 V | Resolution | 0.001 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) | |
60.00 V | Resolution | 0.01 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) | |
600.0 V | Resolution | 0.1 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) | |
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) | |
1000 V | Resolution | 1 V |
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(2% + 3) | |
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) | |
DC Voltage Measurement | ||
Range | Resolution | Accuracy ±(% of Rdg + Counts) |
6.000 V dc | 0.001 V | ±(0.09% + 2) |
60.00 V dc | 0.01 V | ±(0.09% + 2) |
600.0 V dc | 0.1 V | ±(0.09% + 2) |
1000 V dc | 1 V | ±(0.09% + 2) |
Input impedanceÊ | 10 M½ (nominal), <100 pF | |
Normal mode rejection ratioÊ | >60 dB @ 50 Hz or 60 Hz | |
Common mode rejection ratioÊ | >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) | |
Accuracies apply to ± 100% of range | ||
DC Millivolts Measurement | ||
Range | Resolution | Accuracy ±(% of Rdg + Counts) |
600.0 mVdc | 0.1 mV | ±(0.1% + 1) |
DC and AC Current Measurement | ||
AC 45 Hz to 1000 Hz | ||
Range | 400 mA | |
Resolution | 0.1 mA | |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)_ | |
Burden voltage (Typical) | 2 mV/mA | |
Range | 60 mAÊ | |
Resolution | 0.01 mAÊ | |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)_ | |
Burden voltage (Typical) | 2 mV/mA | |
DC | ||
Range | 400 mA | |
Resolution | 0.1 mA | |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) | |
Burden voltage (Typical) | 2 mV/mA | |
Range | 60 mA | |
Resolution | 0.01 mA | |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) | |
Burden voltage (Typical) | 2 mV/mA | |
Overload | 600 mA for 2 minutes maximum | |
Fuse protection for mA input | 0.44 mA, 1000 V, IR 10 kA | |
AC conversion | Inputs are ac-coupled and calibrated to the rms value of sine wave input | |
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ²1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. | ||
_ 1 kHz bandwidth | ||
Ohms Measurement | ||
Range | Resolution | Accuracy +(% of Rdg+Counts)_ |
600.0 ½ | 0.1 ½ | ±(0.9% + 2) |
6.000 k½ | 0.001 k½ | ±(0.9% + 2) |
60.00 k½ | 0.01 k½ | ±(0.9% + 2) |
600.0 k½ | 0.1 K½ | ±(0.9% + 2) |
6.000 M½ | 0.001 M½ | ±(0.9% + 2) |
50.0 M½ _ | 0.01 M½ | ±(1.5% + 3) |
Overload protectionÊ | 1000 V rms or dc | |
Open circuit test voltageÊ | <8.0 V dc | |
Short circuit currentÊ | <1.1 mA | |
_ Accuracies apply from 0% to 100% of range _ Up to 80% relative humidity | ||
Diode Test | ||
Diode test indication | Display voltage drop: 0.6 V at1.0 mA nominal test current: | |
Accuracy | ±(2% + 3) | |
Continuity Test | ||
Continuity indication | Continuous audible tone for testresistance below 25 ½ and off above 100 ½. Maximum Reading; 1000 ½ | |
Open circuit voltage | <8.0 V | |
Short circuit current | 1.0 mA typical | |
Overload protection | 1000 V rms | |
Response time | >1 m sec | |
Frequency Measurement | ||
Range | Resolution | Accuracy ±(% of Rdg+Counts) |
99.99 HzÊ | 0.01 HzÊ | ±(0.1% + 1) |
999.9 HzÊ | 0.1 HzÊ | ±(0.1% + 1) |
9.999 kHzÊ | 0.001 kHzÊ | ±(0.1% + 1) |
99.99 kHzÊ | 0.01 kHzÊ | ±(0.1% + 1) |
Frequency Counter Sensitivity | ||
600.0 mV acÊ | V ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ | 100.0 mVÊ |
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz | 150.0 mVÊ | |
DC Trigger Levels_ to 20 kHz_ | NA | |
6.0 VÊ | V ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ | 1.0 VÊ |
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz | 1.5 VÊ | |
DC Trigger Levels_ to 20 kHz_ | -400.0 mV and 2.5 V | |
60.0 VÊ | V ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ | 10.0 VÊ |
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz | 36.0 VÊ | |
DC Trigger Levels_ to 20 kHz_ | 1.2 V and 4.0 V | |
600.0 VÊ | V ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ | 100.0 VÊ |
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz | - | |
DC Trigger Levels_ to 20 kHz_ | 12.0 V and 40.0 V | |
1000.0 VÊ | V ac Sensitivity (RMS Sine Wave)_ Ê5 Hz to 20 kHzÊ | 300.0 VÊ |
V ac Sensitivity (RMS Sine Wave)_Ê 20 kHz to 100 kHz | - | |
DC Trigger Levels_ to 20 kHz_ | 12.0 V and 40.0 V | |
_ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy _ Usable to 100 kHz with full scale input | ||
Capacitance | ||
RangeÊ | ResolutionÊ | Accuracy ±(% of Rdg+Counts) |
1000 nFÊ | 1 nF | ±(1.2% + 2) |
10.00 _FÊ | 0.01 _F | ±(1.2% + 2) |
100.0 _FÊ | 0.1 _F | ±(1.2% ±90 counts) |
9999 _FÊ | 1 _F | ±(1.2% ±90 counts) |
Temperature Measurement | ||
RangeÊ | ResolutionÊ | Accuracy ±(% of Rdg+Counts)_ |
-40 ¡ C to 537 ¡ CÊ | 0.1 ¡CÊ | ±(1% + 10 counts) |
-40 ¡ F to 998 ¡ FÊ | 0.1 ¡FÊ | ±(1% + 18 counts) |
_ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument | ||
Insulation Specifications | ||
Measurement range | 0.01 M½ to 2 G½ | |
Test voltages | 50, 100, 250, 500, 1000 V | |
Test voltage accuracy | +20%, -0% | |
Short-circuit test current | 1 mA nominal | |
Auto discharge | Discharge time <0.5 second for C = 1 _F or less | |
Live circuit detection | Inhibit test if terminal voltage > 30 V prior to initialization of test | |
Maximum capacitive load | Operable with up to 1 _F load | |
Output Voltage | ||
50 V (0% to +20%) | Display range | 0.01 to 6.00 M½ |
Resolution | 0.01 M½ | |
Test current | 1 mA @ 50 k½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) | |
Display range | 6.0 to 50.0 M½ | |
Resolution | 0.1 M½ | |
Test current | 1 mA @ 50 k½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) | |
100 V (0% to +20%) | Display range | 0.01 to 6.00 M½ |
Resolution | 0.01 M½ | |
Test current | 1 mA @ 100 k½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) | |
Display range | 6.0 to 60.0 M½ | |
Resolution | 0.1 M½ | |
Test current | 1 mA @ 100 k½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) | |
Display range | 60 to 100 M½Ê | |
Resolution | 1 M½ | |
Test current | 1 mA @ 100 k½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) | |
250 V (0% to +20%) | Display range | 0.1 to 60.0 M½Ê |
Resolution | 0.1 M½ | |
Test current | 1 mA @ 250 k½Ê | |
Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) | |
Display range | 60 to 250 M½Ê | |
Resolution | 1 M½ | |
Test current | 1 mA @ 250 k½Ê | |
Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) | |
500 V (0% to +20%) | Display range | 0.1 to 60.0 M½ |
Resolution | 0.1 M½ | |
Test current | 1 mA @ 500 k½Ê | |
Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) | |
Display range | 60 to 500 M½ | |
Resolution | 1 M½ | |
Test current | 1 mA @ 500 k½Ê | |
Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) | |
1000 V (0% to +20%) | Display range | 0.1 to 60.0 M½Ê |
Resolution | 0.1 M½ | |
Test current | 1 mA @ 1 M½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) | |
Display range | 60 to 600 M½Ê | |
Resolution | 1 M½ | |
Test current | 1 mA @ 1 M½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) | |
Display range | 0.6 to 2.0 G½Ê | |
Resolution | 100 M½Ê | |
Test current | 1 mA @ 1 M½ | |
Resistance accuracy ±(% of Rdg + Counts) | ±(10% + 3 counts) | |
General Specifications | ||
Maximum voltage applied to any terminal and common | 1000 V | |
Storage temperature | -40 ¡C to 60 ¡C (-40 ¡F to 140 ¡F) | |
Operating temperature | -20 ¡C to 55 ¡C (-4 ¡F to 131 ¡F) | |
Temperature coefficient | 0.05 x (specified accuracy) per ¡C for temperatures <18 ¡C or >28 ¡C (<64 ¡F or >82 ¡F) | |
Relative humidity | Noncondensing | |
0% to 95% @ 10 ¡C to 30 ¡C (50 ¡F to 86 ¡F) | ||
0% to 75% @ 30 ¡C to 40 ¡C (86 ¡F to 104 ¡F) | ||
0% to 40% @ 40 ¡C to 55 ¡C (104 ¡F to 131 ¡F) | ||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |
Radio frequency communication | 2.4 GHz ISM Band | |
Radio frequency certification | FCC: T68-FBLE, IC: 6627A-FBLE | |
Electromagnetic CompatibilityÊ | ||
International | IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A | |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | ||
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.Ê There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | ||
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. | ||
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Enclosure protection | IEC 60529: IP40 (non-operating) | |
Safety | ||
IEC 61010-1 | Pollution Degree 2 | |
IEC 61010-2-033 | CAT IV 600 V / CAT III 1000 V | |
BatteriesÊ | Four AA batteries (NEDA 15A or IEC LR6) | |
Battery life | Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M½ with a duty cycle of 5 seconds on and 25 seconds off. | |
Size (H x W x L) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) | |
Weight | 550 g (1.2 lb) | |
Altitude | Operating | 2000 m |
Storage | 12,000 m | |
Over-range capability | 110% of range except for capacitance which is 100% | |
Frequency overload protection | <107 V Hz | |
Fuse protection for mA input | 0.44A, 1000 V, IR 10 kA |
Fluke i400 AC Current Clamp
Specifications | |
Nominal current range | 400Ê A |
Continuous current range | 1 A - 400 A |
Maximum non-destructive current | 1000 A |
Lowest measurable current | 1 A |
Basic accuracy | 2% + 0.06 A |
(45-400 Hz) | |
(% reading + floorspec) | |
Useable frequency | 5 Hz - 20 kHz |
Output level(s) | 1 mA/A |
Safety Specifications | |
Safety | CAT IV 600 V, CAT III, 1000 V |
Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 |
Mechanical and General Specifications | |
Warranty | 1 year |
Maximum conductor diameter | 32 mm (1.25 in) |
Maximum conductor size (busbar) | 750 MCM |
Output cable length | 1.5 m (59 in) |
Shrouded banana plugs | Yes |
Fluke 9040 Phase Rotation Indicator
Technical Specifications | |
Voltage range | 40-700 V |
Frequency range | 15-400 Hz |
Operating timer | Continuous |
Environmental Specifications | |
Operating temperature | 0 ¡C to 40 ¡C |
Dust/water resistance | IP 40 |
Safety Specifications | |
Electrical safety | EN 61010, ÊEN 61557-7 |
Overvoltage category | CAT III, 600 V |
CAT IV, 300V | |
Mechanical and General Specifications | |
Size | 124 x 61 x 27 mm |
Weight | 200 g |
Power supply | From unit under test |
Warranty | 2 years |